Email info@acornsci.com for orders and inquiries.

{"id":1582063685,"title":"HI 715 Checker HC ® - Ammonia. MR","handle":"hi715","description":"\u003cp style=\"text-align: justify;\"\u003eThe HI 715 Checker®HC is a simple. accurate. and cost effective way to measure medium ranges of ammonia in fresh water.  Designed as a more accurate alternative to chemical test kits. the HI 715 provides quick. accurate results in four easy steps. \u003cbr\u003e \u003cbr\u003e The HI 715 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-93. Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   The HI 715 Checker®HC is supplied with 2 cuvettes and caps. reagent starter kit (1 bottle of HI 715A-0 and 1 bottle of HI 715B-0). 1 x 1.5V AAA battery. and an instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/hannainst.com\/usa\/images\/icon-pdf.gif\" width=\"20\" height=\"22\" border=\"0\" align=\"absmiddle\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/hannainst.com\/manuals\/ist715_03_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 9.99 ppm NH3-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@20°C\/68°F)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.05ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eColorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePhotodiode @470 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology. D1426-93. Nessler method. The reaction between ammonia and reagents causes a yellow tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBattery - 1 x 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Auto Off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 min. of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2016-09-01T16:13:08+12:00","created_at":"2015-09-01T15:02:05+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["brand_Hanna","category_photometers","Manufacturer_Hanna Instruments"],"price":12200,"price_min":12200,"price_max":12200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857021765,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI715","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HI 715 Checker HC ® - Ammonia. MR","public_title":null,"options":["Default Title"],"price":12200,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-ammoniak-mittel-2416_1-1_2015.jpeg?v=1443494416"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-ammoniak-mittel-2416_1-1_2015.jpeg?v=1443494416","options":["Title"],"media":[{"alt":"HI 715 Checker HC ® - Ammonia. MR - Acorn Scientific","id":21265285219,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-ammoniak-mittel-2416_1-1_2015.jpeg?v=1443494416"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-ammoniak-mittel-2416_1-1_2015.jpeg?v=1443494416","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: justify;\"\u003eThe HI 715 Checker®HC is a simple. accurate. and cost effective way to measure medium ranges of ammonia in fresh water.  Designed as a more accurate alternative to chemical test kits. the HI 715 provides quick. accurate results in four easy steps. \u003cbr\u003e \u003cbr\u003e The HI 715 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-93. Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   The HI 715 Checker®HC is supplied with 2 cuvettes and caps. reagent starter kit (1 bottle of HI 715A-0 and 1 bottle of HI 715B-0). 1 x 1.5V AAA battery. and an instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg alt=\"\" src=\"http:\/\/hannainst.com\/usa\/images\/icon-pdf.gif\" width=\"20\" height=\"22\" border=\"0\" align=\"absmiddle\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/hannainst.com\/manuals\/ist715_03_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 9.99 ppm NH3-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@20°C\/68°F)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.05ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eColorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePhotodiode @470 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology. D1426-93. Nessler method. The reaction between ammonia and reagents causes a yellow tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBattery - 1 x 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Auto Off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 min. of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

HI 715 Checker HC ® - Ammonia. MR

Product Description

The HI 715 Checker®HC is a simple. accurate. and cost effective way to measure medium ranges of ammonia in fresh water.  Designed as a more accurate alternative to chemical test kits. the HI 715 provides quick. accurate results in four easy steps. 
 
The HI 715 uses an adaptation of the ASTM Manual of water and Environmental Technology D1426-93. Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.

Order Information:   The HI 715 Checker®HC is supplied with 2 cuvettes and caps. reagent starter kit (1 bottle of HI 715A-0 and 1 bottle of HI 715B-0). 1 x 1.5V AAA battery. and an instruction manual.

Product Manuals

  Manual: Download

Specification :

Range   0.00 to 9.99 ppm NH3-N
Resolution   0.01 ppm
Accuracy (@20°C/68°F)   ±0.05ppm ±5% of reading
Measurement Method   Colorimetric
Light Source   Photodiode @470 nm
Light Detector   Silicon photocell
Method   Adaptation of the ASTM Manual of Water and Environmental Technology. D1426-93. Nessler method. The reaction between ammonia and reagents causes a yellow tint in the sample.
Power Supply   Battery - 1 x 1.5V AAA
Power Auto Off   After 10 min. of inactivity
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight   64 g (2.25 oz.)

This product is available upon request. Contact us for more information.