{"id":8096133316904,"title":"AIRCLEAN SYSTEMS Endeavour™ - Sliding Sash Ductless","handle":"airclean-systems-endeavour-sliding-sash-ductless","description":"\u003cdiv class=\"o_g parameterList\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_g parameterList\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\"\u003e\n\u003ch2 data-v-34176663=\"\"\u003eProduct Parameters\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAirSafe™ NXT provides touchscreen access to all functions of the Endeavour ductless fume hood. Automatic blower control, filter monitoring, alarm notifications and energy use meter are just a few of the standard features provided by the AirSafe NXT automatic safety controller. ChemMinder™ application acknowledgement system provides the end user with real-time data on approved chemical class.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-2 text-white h5 p-2\"\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegral base with deep spill lip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirZone™ baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating \"dead spots\" within the hood\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVertical sliding safety glass sash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDual wall construction allows for front mounting of services such as water, gas, or electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstant monitoring of fume hood face velocity with variable airflow control to user preset value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLarge capacity filtration bed to handle a wide variety of applications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTouch-screen microprocessor control with variable airflow controller and constant filter monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChemMinder™ chemical class confirmation - user notification of chemical\/filtration compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLab event timer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGas phase bonded carbon filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"sliderTable mt10 mb10 sliderTable-index0\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"sliderTable mt10 mb10 sliderTable-index0\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient text-white h5 p-2\"\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter safety lockout to ensure correct filter replacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirZone\u003csup\u003e™\u003c\/sup\u003e baffling to prevent fume hood roll and provide superior containment of gases and vapors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic gas detection for real-time gas phase filter monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDeep base effectively contains accidental spills\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLow airflow alarm warns the user both visually and audibly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eASHRAE 110 tested\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReal time monitoring of installed filtration bed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-3 text-white h5 p-2\"\u003e\u003cspan\u003eOptions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDeck-mounted fixtures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccess port for electrical cords\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVented and unvented polypropylene base cabinets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSturdy stand with leveling feet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDuplex electrical outlets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eULPA filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCustom access ports for routine equipment maintennce\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolypropylene laboratory sinks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWall mounted fixtures and taps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eHow it Works\u003c\/h4\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cul class=\"list-group list-group-flush\"\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eA\u003c\/span\u003e\n\u003cp\u003eRoom air flows away from the operator and enters the enclosure in a horizontal pattern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eB\u003c\/span\u003e\n\u003cp\u003eRoom air mixes with both lighter and heavier gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eC\u003c\/span\u003e\n\u003cp\u003eMixed air is drawn into the AirZone™ baffling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eD\u003c\/span\u003e\n\u003cp\u003eContaminated air is directed through the filtration bed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eE\u003c\/span\u003e\n\u003cp\u003eClean air is recirculated into the room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003cimg alt=\"Air Flow Diagram\" src=\"https:\/\/www.aircleansystems.com\/img\/diagram\/airflow-diagram-03.svg\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"table-responsive table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth rowspan=\"2\"\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eExternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT3000S\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT3036S\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT4000S\u003c\/td\u003e\n\u003ctd\u003e1220mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT4036S\u003c\/td\u003e\n\u003ctd\u003e1220mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT6000S\u003c\/td\u003e\n\u003ctd\u003e1828mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT6036S\u003c\/td\u003e\n\u003ctd\u003e1828mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT8000S\u003c\/td\u003e\n\u003ctd\u003e2438mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT8036S\u003c\/td\u003e\n\u003ctd\u003e2438mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eInternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT3000S\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e635mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT3036S\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e787mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT4000S\u003c\/td\u003e\n\u003ctd\u003e1118mm\u003c\/td\u003e\n\u003ctd\u003e635mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT4036S\u003c\/td\u003e\n\u003ctd\u003e1118mm\u003c\/td\u003e\n\u003ctd\u003e787mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT6000S\u003c\/td\u003e\n\u003ctd\u003e1676mm\u003c\/td\u003e\n\u003ctd\u003e635mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT6036S\u003c\/td\u003e\n\u003ctd\u003e1676mm\u003c\/td\u003e\n\u003ctd\u003e635mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT8000S\u003c\/td\u003e\n\u003ctd\u003e2286mm\u003c\/td\u003e\n\u003ctd\u003e635mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT8036S\u003c\/td\u003e\n\u003ctd\u003e2286mm\u003c\/td\u003e\n\u003ctd\u003e787mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2023-02-02T14:33:18+13:00","created_at":"2023-02-02T13:56:00+13:00","vendor":"AirClean Systems","type":"Fume Hoods","tags":["Category_Fume Hoods","Features_Ductless","Manufacturer_Airclean Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":44987627962664,"title":"Fume Hoods \/ Ductless","option1":"Fume Hoods","option2":"Ductless","option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AIRCLEAN SYSTEMS Endeavour™ - Sliding Sash Ductless - Fume Hoods \/ Ductless","public_title":"Fume Hoods \/ Ductless","options":["Fume Hoods","Ductless"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/endeavour-ductless-fume-hood-sliding-sash-1.webp?v=1675301590","\/\/acornsci.co.nz\/cdn\/shop\/products\/endeavour-ductless-fume-hood-sliding-sash-2.webp?v=1675301592","\/\/acornsci.co.nz\/cdn\/shop\/products\/endeavour-ductless-fume-hood-sliding-sash-3.webp?v=1675301594"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/endeavour-ductless-fume-hood-sliding-sash-1.webp?v=1675301590","options":["Category","Features"],"media":[{"alt":null,"id":33102217445672,"position":1,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/endeavour-ductless-fume-hood-sliding-sash-1.webp?v=1675301590"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/endeavour-ductless-fume-hood-sliding-sash-1.webp?v=1675301590","width":700},{"alt":null,"id":33102217511208,"position":2,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/endeavour-ductless-fume-hood-sliding-sash-2.webp?v=1675301592"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/endeavour-ductless-fume-hood-sliding-sash-2.webp?v=1675301592","width":700},{"alt":null,"id":33102217969960,"position":3,"preview_image":{"aspect_ratio":1.07,"height":1402,"width":1500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/endeavour-ductless-fume-hood-sliding-sash-3.webp?v=1675301594"},"aspect_ratio":1.07,"height":1402,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/endeavour-ductless-fume-hood-sliding-sash-3.webp?v=1675301594","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv class=\"o_g parameterList\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_g parameterList\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\"\u003e\n\u003ch2 data-v-34176663=\"\"\u003eProduct Parameters\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAirSafe™ NXT provides touchscreen access to all functions of the Endeavour ductless fume hood. Automatic blower control, filter monitoring, alarm notifications and energy use meter are just a few of the standard features provided by the AirSafe NXT automatic safety controller. ChemMinder™ application acknowledgement system provides the end user with real-time data on approved chemical class.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-2 text-white h5 p-2\"\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegral base with deep spill lip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWide range of bonded activated carbon and HEPA filters for containment of virtually any toxic vapor, fume, gas, or particulate\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirZone™ baffling establishes a proper horizontal airflow pattern and directs toxins away from the operator in a predictable pattern, eliminating \"dead spots\" within the hood\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVertical sliding safety glass sash\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDual wall construction allows for front mounting of services such as water, gas, or electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eConstant monitoring of fume hood face velocity with variable airflow control to user preset value\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLarge capacity filtration bed to handle a wide variety of applications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTouch-screen microprocessor control with variable airflow controller and constant filter monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eChemMinder™ chemical class confirmation - user notification of chemical\/filtration compatibility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLab event timer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGas phase bonded carbon filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"sliderTable mt10 mb10 sliderTable-index0\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"sliderTable mt10 mb10 sliderTable-index0\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient text-white h5 p-2\"\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter safety lockout to ensure correct filter replacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirZone\u003csup\u003e™\u003c\/sup\u003e baffling to prevent fume hood roll and provide superior containment of gases and vapors\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic gas detection for real-time gas phase filter monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDeep base effectively contains accidental spills\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLow airflow alarm warns the user both visually and audibly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eASHRAE 110 tested\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eReal time monitoring of installed filtration bed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-3 text-white h5 p-2\"\u003e\u003cspan\u003eOptions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDeck-mounted fixtures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAccess port for electrical cords\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eVented and unvented polypropylene base cabinets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSturdy stand with leveling feet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDuplex electrical outlets\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eULPA filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCustom access ports for routine equipment maintennce\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePolypropylene laboratory sinks\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWall mounted fixtures and taps\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eHow it Works\u003c\/h4\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cul class=\"list-group list-group-flush\"\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eA\u003c\/span\u003e\n\u003cp\u003eRoom air flows away from the operator and enters the enclosure in a horizontal pattern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eB\u003c\/span\u003e\n\u003cp\u003eRoom air mixes with both lighter and heavier gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eC\u003c\/span\u003e\n\u003cp\u003eMixed air is drawn into the AirZone™ baffling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eD\u003c\/span\u003e\n\u003cp\u003eContaminated air is directed through the filtration bed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eE\u003c\/span\u003e\n\u003cp\u003eClean air is recirculated into the room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003cimg alt=\"Air Flow Diagram\" src=\"https:\/\/www.aircleansystems.com\/img\/diagram\/airflow-diagram-03.svg\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"table-responsive table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth rowspan=\"2\"\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eExternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT3000S\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT3036S\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT4000S\u003c\/td\u003e\n\u003ctd\u003e1220mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT4036S\u003c\/td\u003e\n\u003ctd\u003e1220mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT6000S\u003c\/td\u003e\n\u003ctd\u003e1828mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT6036S\u003c\/td\u003e\n\u003ctd\u003e1828mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT8000S\u003c\/td\u003e\n\u003ctd\u003e2438mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT8036S\u003c\/td\u003e\n\u003ctd\u003e2438mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003ctd\u003e1524mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eInternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT3000S\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e635mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT3036S\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003ctd\u003e787mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT4000S\u003c\/td\u003e\n\u003ctd\u003e1118mm\u003c\/td\u003e\n\u003ctd\u003e635mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT4036S\u003c\/td\u003e\n\u003ctd\u003e1118mm\u003c\/td\u003e\n\u003ctd\u003e787mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT6000S\u003c\/td\u003e\n\u003ctd\u003e1676mm\u003c\/td\u003e\n\u003ctd\u003e635mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT6036S\u003c\/td\u003e\n\u003ctd\u003e1676mm\u003c\/td\u003e\n\u003ctd\u003e635mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT8000S\u003c\/td\u003e\n\u003ctd\u003e2286mm\u003c\/td\u003e\n\u003ctd\u003e635mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eACPT8036S\u003c\/td\u003e\n\u003ctd\u003e2286mm\u003c\/td\u003e\n\u003ctd\u003e787mm\u003c\/td\u003e\n\u003ctd\u003e914mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}