{"id":2031632901,"title":"Hanna BL983322-1Conductivity Mini Controller. 0 to 19.99 µS\/cm. 230V","handle":"bl-983322-1","description":"\u003cp\u003eEasy to handle\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFire retardant casing\u003c\/li\u003e\n\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cli\u003eSplash resistant cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis HANNA mini controller has been specially designed for water conditioning and growing applications. Compact in size. it can be mounted in confined spaces or even right next to the vat or barrel containing the chemicals. This meter permits automatic control of installations previously checked manually.\u003c\/p\u003e\n\u003cp\u003eEC measurements are shown on the display and the multicolored LED continuously indicates if the mini controller is in measurement. dosing or alarm mode. BL 983322 from 0.00 to 19.99 µS\/cm.\u003c\/p\u003e\n\u003cp\u003eUsers can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations. because it permits operators to enable or disable the dosing relay according to need. The overtime control system advices users when the relay is active for too long. helping to prevent over dosage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eBL 983322-1 ( 115\/230V) are supplied with mounting brackets. transparent cover and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manBL_983322.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 19.99 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7634-00 EC\/TDS probe with internal temperature sensor and 2 m (6.6’) cable (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic. 5 to 50°C (41 to 122°F) with ß = 2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Relay\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected). 250 Vac. 30 VDC contact close when measure \u0026gt; set point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 19.99 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvertime\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadjustable. typically from 5 to approx. 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSee Chart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2026-06-25T15:09:21+12:00","created_at":"2015-09-07T15:08:08+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Category_Conductivity","Manufacturer_Hanna Instruments","Type_Meters"],"price":30400,"price_min":30400,"price_max":30400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5832159685,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"BL983322-1","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"Hanna BL983322-1Conductivity Mini Controller. 0 to 19.99 µS\/cm. 230V","public_title":null,"options":["Default Title"],"price":30400,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/ec-miniregler-bis-1999-scm-12v-34_1-151dfc65dab3ae_2015.jpeg?v=1469183947","\/\/acornsci.co.nz\/cdn\/shop\/products\/dim251dfb345dec34_2015_f620ab76-26f0-4ad0-9109-a03b6267d38d.png?v=1469183947","\/\/acornsci.co.nz\/cdn\/shop\/products\/dim51dfb347ef6d6_2015_8383a951-9b65-411d-bfe9-4c799736716e.png?v=1469183948"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/ec-miniregler-bis-1999-scm-12v-34_1-151dfc65dab3ae_2015.jpeg?v=1469183947","options":["Title"],"media":[{"alt":"BL 983322-1Conductivity Mini Controller. 0 to 19.99 µS\/cm. 230V - Acorn Scientific","id":25252462691,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/ec-miniregler-bis-1999-scm-12v-34_1-151dfc65dab3ae_2015.jpeg?v=1469183947"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/ec-miniregler-bis-1999-scm-12v-34_1-151dfc65dab3ae_2015.jpeg?v=1469183947","width":500},{"alt":"BL 983322-1Conductivity Mini Controller. 0 to 19.99 µS\/cm. 230V - Acorn Scientific","id":25252495459,"position":2,"preview_image":{"aspect_ratio":0.879,"height":340,"width":299,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/dim251dfb345dec34_2015_f620ab76-26f0-4ad0-9109-a03b6267d38d.png?v=1469183947"},"aspect_ratio":0.879,"height":340,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/dim251dfb345dec34_2015_f620ab76-26f0-4ad0-9109-a03b6267d38d.png?v=1469183947","width":299},{"alt":"BL 983322-1Conductivity Mini Controller. 0 to 19.99 µS\/cm. 230V - Acorn Scientific","id":25252528227,"position":3,"preview_image":{"aspect_ratio":0.991,"height":351,"width":348,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/dim51dfb347ef6d6_2015_8383a951-9b65-411d-bfe9-4c799736716e.png?v=1469183948"},"aspect_ratio":0.991,"height":351,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/dim51dfb347ef6d6_2015_8383a951-9b65-411d-bfe9-4c799736716e.png?v=1469183948","width":348}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eEasy to handle\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFire retardant casing\u003c\/li\u003e\n\u003cli\u003eSelectable overdose protection system\u003c\/li\u003e\n\u003cli\u003eSplash resistant cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis HANNA mini controller has been specially designed for water conditioning and growing applications. Compact in size. it can be mounted in confined spaces or even right next to the vat or barrel containing the chemicals. This meter permits automatic control of installations previously checked manually.\u003c\/p\u003e\n\u003cp\u003eEC measurements are shown on the display and the multicolored LED continuously indicates if the mini controller is in measurement. dosing or alarm mode. BL 983322 from 0.00 to 19.99 µS\/cm.\u003c\/p\u003e\n\u003cp\u003eUsers can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations. because it permits operators to enable or disable the dosing relay according to need. The overtime control system advices users when the relay is active for too long. helping to prevent over dosage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eBL 983322-1 ( 115\/230V) are supplied with mounting brackets. transparent cover and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manBL_983322.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 19.99 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7634-00 EC\/TDS probe with internal temperature sensor and 2 m (6.6’) cable (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic. 5 to 50°C (41 to 122°F) with ß = 2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Relay\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected). 250 Vac. 30 VDC contact close when measure \u0026gt; set point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 19.99 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvertime\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadjustable. typically from 5 to approx. 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSee Chart\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e79 x 49 x 95 mm (3.1 x 1.9 x 3.7’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}