Email info@acornsci.com for orders and inquiries.

{"id":1582183621,"title":"HANNA HI 1002\/5 Flow-thru Monitoring pH Electrode with BNC Connection and 5 m Cable","handle":"hi-1002-5","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003eFlow-thru monitoring pH electrode with BNC connection and 5 m cable.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cbr\u003eSpecifically Built for Industrial Applications\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e½\" NPT external thread for in-line installation\u003c\/li\u003e\n\u003cli\u003epH electrode with exclusive PTFE non-clogging membrane\u003c\/li\u003e\n\u003cli\u003eDouble-junction technology\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003eModels with built-in matching pin and amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).\u003c\/p\u003e\n\u003cp\u003eBoth pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.\u003c\/p\u003e\n\u003cp\u003eHI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH\/ORP meter quick and easy; models with 3 or 5 meters (9.8 or 16 feet) cable are available.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eDimensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edouble. PTFE\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003epolymer\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMatching Pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eno\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eno\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5 to 80°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e6 bar (87 psi)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eBNC\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e5 m\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/images\/imgDia_1000_ph_electrode.jpg\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T15:55:34+12:00","created_at":"2015-09-01T15:18:13+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Electrodes \u0026 Probes"],"price":30210,"price_min":30210,"price_max":30210,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857326533,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI1002\/5","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 1002\/5 Flow-thru Monitoring pH Electrode with BNC Connection and 5 m Cable","public_title":null,"options":["Default Title"],"price":30210,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi1002-5_20052eb6ad844099_2015.jpeg?v=1465536286"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi1002-5_20052eb6ad844099_2015.jpeg?v=1465536286","options":["Title"],"media":[{"alt":"HI 1002\/5 Flow-thru Monitoring pH Electrode with BNC Connection and 5 m Cable - Acorn Scientific","id":21306933347,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi1002-5_20052eb6ad844099_2015.jpeg?v=1465536286"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi1002-5_20052eb6ad844099_2015.jpeg?v=1465536286","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003eFlow-thru monitoring pH electrode with BNC connection and 5 m cable.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cbr\u003eSpecifically Built for Industrial Applications\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e½\" NPT external thread for in-line installation\u003c\/li\u003e\n\u003cli\u003epH electrode with exclusive PTFE non-clogging membrane\u003c\/li\u003e\n\u003cli\u003eDouble-junction technology\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003eModels with built-in matching pin and amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).\u003c\/p\u003e\n\u003cp\u003eBoth pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.\u003c\/p\u003e\n\u003cp\u003eHI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH\/ORP meter quick and easy; models with 3 or 5 meters (9.8 or 16 feet) cable are available.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eDimensions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edouble. PTFE\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003epolymer\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMatching Pin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eno\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmplifier\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eno\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5 to 80°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e6 bar (87 psi)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eBNC\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e5 m\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/images\/imgDia_1000_ph_electrode.jpg\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 1002/5 Flow-thru Monitoring pH Electrode with BNC Connection and 5 m Cable

Product Description

 

Flow-thru monitoring pH electrode with BNC connection and 5 m cable.


Specifically Built for Industrial Applications

 

  • ½" NPT external thread for in-line installation
  • pH electrode with exclusive PTFE non-clogging membrane
  • Double-junction technology
  • PVDF body
  • Models with built-in matching pin and amplifier

 

In order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).

Both pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.

HI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH/ORP meter quick and easy; models with 3 or 5 meters (9.8 or 16 feet) cable are available.

 

  • Specifications
  • Dimensions
Junction   double. PTFE
Electrolyte   polymer
Matching Pin   no
Amplifier   no
Temperature   -5 to 80°C
Max Pressure   6 bar (87 psi)
Connection   BNC
Cable   5 m

This product is available upon request. Contact us for more information.