Email info@acornsci.com for orders and inquiries.

{"id":1582152709,"title":"HANNA HI 3090T Combination Glass-body ORP Electrode with Pt Sensor and 3 bar max pressure","handle":"hi3090t","description":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003eCombination glass-body ORP electrode with platinum sensor and 3 bar max pressure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eScrew cap connector and PG 13.5 thread\u003c\/li\u003e\n\u003cli\u003eEasy operation\u003c\/li\u003e\n\u003cli\u003eDouble-junction technology\u003c\/li\u003e\n\u003cli\u003ePressure up to 3 bar (43.5 PSI)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eElectrodes featuring a T-connector have been designed by HANNA to gain the advantages of both PG 13.5 thread and screw cap. The PG 13.5 thread ensures proper in-line installation. furthermore. the user can quickly and easily perform all servicing and maintenance procedures. The screw cap allows for maximum versatility making it possible to connect a cable of different lengths. Easily detacheable cables make electrode replacement simple.\u003c\/p\u003e\n\u003cp\u003eMany models are available to choose from. all of which feature a double junction of gel polymer filling to ensure long electrode life and reliability in harsh environments. In addition. users can select from ground-glass or cloth junction technology to meet the needs of their specific application.\u003c\/p\u003e\n\u003cp\u003eElectrodes featuring a PEI body are ideal for use in moderately aggressive liquids. such as in wastewater. while electrodes featuring glass bodies are recommended with more aggressive chemicals. such as in galvanic applications.\u003c\/p\u003e\n\u003cp\u003eThese sensors are also suitable to be operated with moderate pressure up to 3 bar (43.5 psi) and operating temperature limits of -5 up to 95ºC (23 to 203ºF).\u003c\/p\u003e\n\u003cp\u003eHANNA electrode holders and assemblies are featured at the end of this section for in-line and submersion applications. These optional accessories can be dismantled and reassembled easily without requiring any special tools.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eglass\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edouble. PTFE\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003epolymer\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5 to 95°C (23-203°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e3 bar (43.5 psi)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eT-type\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:19:10+12:00","created_at":"2015-09-01T15:14:10+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Electrodes \u0026 Probes"],"price":28880,"price_min":28880,"price_max":28880,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857273541,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI3090T","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 3090T Combination Glass-body ORP Electrode with Pt Sensor and 3 bar max pressure","public_title":null,"options":["Default Title"],"price":28880,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e6e17e06aad_2015_9f684d63-5d91-4d61-87df-1ad01f270e76.jpeg?v=1465536592"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e6e17e06aad_2015_9f684d63-5d91-4d61-87df-1ad01f270e76.jpeg?v=1465536592","options":["Title"],"media":[{"alt":"HI 3090T Combination Glass-body ORP Electrode with Pt Sensor and 3 bar max pressure - Acorn Scientific","id":21295136867,"position":1,"preview_image":{"aspect_ratio":1.0,"height":300,"width":300,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e6e17e06aad_2015_9f684d63-5d91-4d61-87df-1ad01f270e76.jpeg?v=1465536592"},"aspect_ratio":1.0,"height":300,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e6e17e06aad_2015_9f684d63-5d91-4d61-87df-1ad01f270e76.jpeg?v=1465536592","width":300}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003eCombination glass-body ORP electrode with platinum sensor and 3 bar max pressure.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eScrew cap connector and PG 13.5 thread\u003c\/li\u003e\n\u003cli\u003eEasy operation\u003c\/li\u003e\n\u003cli\u003eDouble-junction technology\u003c\/li\u003e\n\u003cli\u003ePressure up to 3 bar (43.5 PSI)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eElectrodes featuring a T-connector have been designed by HANNA to gain the advantages of both PG 13.5 thread and screw cap. The PG 13.5 thread ensures proper in-line installation. furthermore. the user can quickly and easily perform all servicing and maintenance procedures. The screw cap allows for maximum versatility making it possible to connect a cable of different lengths. Easily detacheable cables make electrode replacement simple.\u003c\/p\u003e\n\u003cp\u003eMany models are available to choose from. all of which feature a double junction of gel polymer filling to ensure long electrode life and reliability in harsh environments. In addition. users can select from ground-glass or cloth junction technology to meet the needs of their specific application.\u003c\/p\u003e\n\u003cp\u003eElectrodes featuring a PEI body are ideal for use in moderately aggressive liquids. such as in wastewater. while electrodes featuring glass bodies are recommended with more aggressive chemicals. such as in galvanic applications.\u003c\/p\u003e\n\u003cp\u003eThese sensors are also suitable to be operated with moderate pressure up to 3 bar (43.5 psi) and operating temperature limits of -5 up to 95ºC (23 to 203ºF).\u003c\/p\u003e\n\u003cp\u003eHANNA electrode holders and assemblies are featured at the end of this section for in-line and submersion applications. These optional accessories can be dismantled and reassembled easily without requiring any special tools.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBody Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eglass\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edouble. PTFE\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003epolymer\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5 to 95°C (23-203°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e3 bar (43.5 psi)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eT-type\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 3090T Combination Glass-body ORP Electrode with Pt Sensor and 3 bar max pressure

Product Description

Combination glass-body ORP electrode with platinum sensor and 3 bar max pressure.

 

  • Screw cap connector and PG 13.5 thread
  • Easy operation
  • Double-junction technology
  • Pressure up to 3 bar (43.5 PSI)

 

Electrodes featuring a T-connector have been designed by HANNA to gain the advantages of both PG 13.5 thread and screw cap. The PG 13.5 thread ensures proper in-line installation. furthermore. the user can quickly and easily perform all servicing and maintenance procedures. The screw cap allows for maximum versatility making it possible to connect a cable of different lengths. Easily detacheable cables make electrode replacement simple.

Many models are available to choose from. all of which feature a double junction of gel polymer filling to ensure long electrode life and reliability in harsh environments. In addition. users can select from ground-glass or cloth junction technology to meet the needs of their specific application.

Electrodes featuring a PEI body are ideal for use in moderately aggressive liquids. such as in wastewater. while electrodes featuring glass bodies are recommended with more aggressive chemicals. such as in galvanic applications.

These sensors are also suitable to be operated with moderate pressure up to 3 bar (43.5 psi) and operating temperature limits of -5 up to 95ºC (23 to 203ºF).

HANNA electrode holders and assemblies are featured at the end of this section for in-line and submersion applications. These optional accessories can be dismantled and reassembled easily without requiring any special tools.

 

  • Specifications
Body Material   glass
Junction   double. PTFE
Electrolyte   polymer
Temperature   -5 to 95°C (23-203°F)
Max Pressure   3 bar (43.5 psi)
Connector   T-type

This product is available upon request. Contact us for more information.