{"id":1582108485,"title":"HANNA HI38066 CTK Calcium in Irrigation Water","handle":"hi38086","description":"\u003cp\u003eHardness in water is mainly due to the presence of Calcium and Magnesium ions and each contributes to the amount of total hardness. Monitoring and controlling hardness is instrumental in order to prevent scaling and corrosion.\u003c\/p\u003e\u003cp\u003eThe HI 38086 test kit determines calcium in water via a turbidimetric method. HANNA reagents react selectively with calcium to form a white suspension. The developed turbidity is proportional to calcium concentration.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e HI 38086 test kit comes with 30 mL buffer reagent. oxalate reagent (100 packets). 500 mL deionized water. 50 mL glass test tube. 50 mL calibrated vessel. 1 mL plastic pipette. plastic spoon. graduated card and line card.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_38086.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/manHI_38086.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTurbidimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0-125 mg\/L\u003cbr\u003e 0-250 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest Increment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003cbr\u003e 2 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTurbidimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Tests\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e950 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e","published_at":"2026-06-25T16:28:38+12:00","created_at":"2015-09-01T15:08:44+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Chemical Test Kits"],"price":11100,"price_min":11100,"price_max":11100,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857182533,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI38086","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI38066 CTK Calcium in Irrigation Water","public_title":null,"options":["Default Title"],"price":11100,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/31gluhj8kul__sl500_aa300_51e056a290d68_2015.jpeg?v=1443495032"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/31gluhj8kul__sl500_aa300_51e056a290d68_2015.jpeg?v=1443495032","options":["Title"],"media":[{"alt":"HANNA HI38066 CTK Calcium in Irrigation Water - Acorn Scientific","id":21280161891,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/31gluhj8kul__sl500_aa300_51e056a290d68_2015.jpeg?v=1443495032"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/31gluhj8kul__sl500_aa300_51e056a290d68_2015.jpeg?v=1443495032","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eHardness in water is mainly due to the presence of Calcium and Magnesium ions and each contributes to the amount of total hardness. Monitoring and controlling hardness is instrumental in order to prevent scaling and corrosion.\u003c\/p\u003e\u003cp\u003eThe HI 38086 test kit determines calcium in water via a turbidimetric method. HANNA reagents react selectively with calcium to form a white suspension. The developed turbidity is proportional to calcium concentration.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e HI 38086 test kit comes with 30 mL buffer reagent. oxalate reagent (100 packets). 500 mL deionized water. 50 mL glass test tube. 50 mL calibrated vessel. 1 mL plastic pipette. plastic spoon. graduated card and line card.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_38086.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/manHI_38086.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTurbidimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0-125 mg\/L\u003cbr\u003e 0-250 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest Increment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003cbr\u003e 2 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTurbidimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Tests\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e950 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e"}

HANNA HI38066 CTK Calcium in Irrigation Water

Product Description

Hardness in water is mainly due to the presence of Calcium and Magnesium ions and each contributes to the amount of total hardness. Monitoring and controlling hardness is instrumental in order to prevent scaling and corrosion.

The HI 38086 test kit determines calcium in water via a turbidimetric method. HANNA reagents react selectively with calcium to form a white suspension. The developed turbidity is proportional to calcium concentration.

 

 

Order Information:
HI 38086 test kit comes with 30 mL buffer reagent. oxalate reagent (100 packets). 500 mL deionized water. 50 mL glass test tube. 50 mL calibrated vessel. 1 mL plastic pipette. plastic spoon. graduated card and line card.

Product Manuals

  Manual: Download

Method   Turbidimetric
Range   0-125 mg/L
0-250 mg/L
Smallest Increment   1 mg/L
2 mg/L
Chemical Method   Turbidimetric
Number of Tests   100
Weight   950 g