Email info@acornsci.com for orders and inquiries.

{"id":1582063493,"title":"HI 713 Checker HC ® - Phosphate. LR","handle":"hi713","description":"\u003cp style=\"text-align: justify;\"\u003eOrthophosphates are found in natural and wastewaters. They are commonly added to drinking water as a corrosion inhibitor. The instantaneous analysis of orthophosphate by colorimetric determination provides rapid results using a standard analysis technique.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HANNA HI 713 Checker\u003csmall\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/small\u003eHC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give only a few resolution points while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The HANNA HI 713 Checker\u003csup\u003e\u003csmall\u003e®\u003c\/small\u003e\u003c\/sup\u003eHC is accurate and affordable.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 713 Checker®HC portable handheld colorimeter features a resolution of 0.01 ppm (250 points) and ±0.04 ppm (mg\/L) ±4% of reading accuracy. The HI 713 Checker®HC uses an adaptation of Standard Method 4500-P E. Ascorbic Acid method.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 713 Checker\u003csup\u003e\u003csmall\u003e®\u003c\/small\u003e\u003c\/sup\u003eHC is extremely simple to use. First. zero the instrument with your water sample. Next. add the reagents. Last. place the vial into the Checker\u003csup\u003e\u003csmall\u003e®\u003c\/small\u003e\u003c\/sup\u003eHC. press the button and read the results. It’s that easy.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 713 Checker®HC is supplied with sample cuvettes with caps (2). powder reagents for phosphate (6). battery and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/hannainst.com\/manuals\/ist713_03_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 25°C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.04 ppm (mg\/L) ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter two minutes of non-use and ten seconds after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater. 20th edition. Ascorbic Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2016-09-01T16:12:53+12:00","created_at":"2015-09-01T15:02:04+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["brand_Hanna","category_photometers","Manufacturer_Hanna Instruments"],"price":8900,"price_min":8900,"price_max":8900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857021445,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI713","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HI 713 Checker HC ® - Phosphate. LR","public_title":null,"options":["Default Title"],"price":8900,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi713_lg51caffcdce23e_2015.jpeg?v=1465537256"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi713_lg51caffcdce23e_2015.jpeg?v=1465537256","options":["Title"],"media":[{"alt":"HI 713 Checker HC ® - Phosphate. LR - Acorn Scientific","id":21265252451,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi713_lg51caffcdce23e_2015.jpeg?v=1465537256"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi713_lg51caffcdce23e_2015.jpeg?v=1465537256","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: justify;\"\u003eOrthophosphates are found in natural and wastewaters. They are commonly added to drinking water as a corrosion inhibitor. The instantaneous analysis of orthophosphate by colorimetric determination provides rapid results using a standard analysis technique.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HANNA HI 713 Checker\u003csmall\u003e\u003csup\u003e®\u003c\/sup\u003e\u003c\/small\u003eHC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give only a few resolution points while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The HANNA HI 713 Checker\u003csup\u003e\u003csmall\u003e®\u003c\/small\u003e\u003c\/sup\u003eHC is accurate and affordable.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 713 Checker®HC portable handheld colorimeter features a resolution of 0.01 ppm (250 points) and ±0.04 ppm (mg\/L) ±4% of reading accuracy. The HI 713 Checker®HC uses an adaptation of Standard Method 4500-P E. Ascorbic Acid method.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 713 Checker\u003csup\u003e\u003csmall\u003e®\u003c\/small\u003e\u003c\/sup\u003eHC is extremely simple to use. First. zero the instrument with your water sample. Next. add the reagents. Last. place the vial into the Checker\u003csup\u003e\u003csmall\u003e®\u003c\/small\u003e\u003c\/sup\u003eHC. press the button and read the results. It’s that easy.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 713 Checker®HC is supplied with sample cuvettes with caps (2). powder reagents for phosphate (6). battery and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/hannainst.com\/manuals\/ist713_03_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 25°C\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.04 ppm (mg\/L) ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter two minutes of non-use and ten seconds after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater. 20th edition. Ascorbic Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

HI 713 Checker HC ® - Phosphate. LR

Product Description

Orthophosphates are found in natural and wastewaters. They are commonly added to drinking water as a corrosion inhibitor. The instantaneous analysis of orthophosphate by colorimetric determination provides rapid results using a standard analysis technique.

The HANNA HI 713 Checker®HC bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate and only give only a few resolution points while professional instrumentation can cost hundreds of dollars and can be time consuming to calibrate and maintain. The HANNA HI 713 Checker®HC is accurate and affordable.

The HI 713 Checker®HC portable handheld colorimeter features a resolution of 0.01 ppm (250 points) and ±0.04 ppm (mg/L) ±4% of reading accuracy. The HI 713 Checker®HC uses an adaptation of Standard Method 4500-P E. Ascorbic Acid method.

The HI 713 Checker®HC is extremely simple to use. First. zero the instrument with your water sample. Next. add the reagents. Last. place the vial into the Checker®HC. press the button and read the results. It’s that easy.

 

Order Information:   HI 713 Checker®HC is supplied with sample cuvettes with caps (2). powder reagents for phosphate (6). battery and instructions.

Product Manuals

  Manual: Download

Specification :

Range   0.00 to 2.50 ppm (mg/L)
Resolution   0.01 ppm (mg/L)
Accuracy @ 25°C   ±0.04 ppm (mg/L) ±4% of reading
Light Source   LED @ 525 nm
Light Detector   silicon photocell
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Battery Type   (1) 1.5V AAA
Auto-off   after two minutes of non-use and ten seconds after reading
Dimensions   81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”)
Weight   64 g (2.25 oz.)
Method   adaptation of the Standard Methods for the Examination of Water and Wastewater. 20th edition. Ascorbic Acid method

This product is available upon request. Contact us for more information.