{"id":1582167109,"title":"HANNA HI 8033 uS\/mS\/TDS Meter (Basic)","handle":"hi8033","description":"\u003cp\u003eHI 8033 is a handheld conductivity meter with the ability to take measurements in three different ranges.\u003c\/p\u003e\n\u003cp\u003eThe included HI 76301W probe utilizes the four-ring potentiometric method which measures conductivity with the utmost accuracy and reliability.\u003c\/p\u003e\n\u003cp\u003eThe four stainless steel rings are embedded in the resin shaft of the probe to create a smooth surface for fast and easy cleaning.\u003c\/p\u003e\n\u003cp\u003eTo improve accuracy in measurements. temperature compensation can be achieved with a knob on the front panel of the meter. The dial on the front of the HI 8033 easily indicates which range you are working in.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 8033 is supplied with HI 76301W conductivity probe. calibration screwdriver. battery and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_8033_933000.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e0.0 to 199.9 µS\/cm; 0 to 1999 µS\/cm; 0.00 to 19.99 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTDS\u003c\/td\u003e\n\u003ctd\u003e0 to 19990 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e0.1 µS\/cm; 1 µS\/cm; 0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eTDS\u003c\/td\u003e\n\u003ctd\u003e10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1% F.S. (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. 1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. 0 to 50°C (32 to 122°F) with ß=2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 76301W EC\/TDS probe with 1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 x 9V \/ approx. 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e185 x 82 x 47 mm (7.3 x 3.2 x 1.9\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e270 g (9.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","published_at":"2026-06-25T16:10:04+12:00","created_at":"2015-09-01T15:15:50+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters"],"price":70200,"price_min":70200,"price_max":70200,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857296197,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI8033","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 8033 uS\/mS\/TDS Meter (Basic)","public_title":null,"options":["Default Title"],"price":70200,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi8033_200_2015.jpeg?v=1443495658"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi8033_200_2015.jpeg?v=1443495658","options":["Title"],"media":[{"alt":null,"id":21300019299,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi8033_200_2015.jpeg?v=1443495658"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi8033_200_2015.jpeg?v=1443495658","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eHI 8033 is a handheld conductivity meter with the ability to take measurements in three different ranges.\u003c\/p\u003e\n\u003cp\u003eThe included HI 76301W probe utilizes the four-ring potentiometric method which measures conductivity with the utmost accuracy and reliability.\u003c\/p\u003e\n\u003cp\u003eThe four stainless steel rings are embedded in the resin shaft of the probe to create a smooth surface for fast and easy cleaning.\u003c\/p\u003e\n\u003cp\u003eTo improve accuracy in measurements. temperature compensation can be achieved with a knob on the front panel of the meter. The dial on the front of the HI 8033 easily indicates which range you are working in.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 8033 is supplied with HI 76301W conductivity probe. calibration screwdriver. battery and instructions.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_8033_933000.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e0.0 to 199.9 µS\/cm; 0 to 1999 µS\/cm; 0.00 to 19.99 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTDS\u003c\/td\u003e\n\u003ctd\u003e0 to 19990 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eEC\u003c\/td\u003e\n\u003ctd\u003e0.1 µS\/cm; 1 µS\/cm; 0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eTDS\u003c\/td\u003e\n\u003ctd\u003e10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1% F.S. (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. 1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. 0 to 50°C (32 to 122°F) with ß=2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 76301W EC\/TDS probe with 1 m (3.3') cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 x 9V \/ approx. 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e185 x 82 x 47 mm (7.3 x 3.2 x 1.9\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e270 g (9.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e"}

HANNA HI 8033 uS/mS/TDS Meter (Basic)

Product Description

HI 8033 is a handheld conductivity meter with the ability to take measurements in three different ranges.

The included HI 76301W probe utilizes the four-ring potentiometric method which measures conductivity with the utmost accuracy and reliability.

The four stainless steel rings are embedded in the resin shaft of the probe to create a smooth surface for fast and easy cleaning.

To improve accuracy in measurements. temperature compensation can be achieved with a knob on the front panel of the meter. The dial on the front of the HI 8033 easily indicates which range you are working in.

 

Order Information:   HI 8033 is supplied with HI 76301W conductivity probe. calibration screwdriver. battery and instructions.

Product Manuals

  Manual: Download

Specification :

Range EC 0.0 to 199.9 µS/cm; 0 to 1999 µS/cm; 0.00 to 19.99 mS/cm
Range TDS 0 to 19990 ppm
Resolution EC 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm
Resolution TDS 10 ppm
Accuracy   ±1% F.S. (excluding probe error)
Calibration   manual. 1 point
Temperature Compensation   manual. 0 to 50°C (32 to 122°F) with ß=2%/°C
Probe   HI 76301W EC/TDS probe with 1 m (3.3') cable (included)
Battery Type / Life   1 x 9V / approx. 100 hours of continuous use
Environment   0 to 50°C (32 to 122°F); RH max 95%
Dimensions   185 x 82 x 47 mm (7.3 x 3.2 x 1.9")
Weight   270 g (9.5 oz.)

 