{"id":1582094405,"title":"HANNA HI 8734 TDS Meter with Multi-Range 0.0 to 19.99 g\/L (ppt).","handle":"hi8734","description":"\u003cp style=\"text-align: justify;\"\u003eHI 8734 has not only been specifically designed for the water conditioning industry. but particularly in the softening. demineralization. reverse osmosis and drinking water applications.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThree ranges of measurement ensure the highest accuracy possible. All three ranges can be executed at the touch of a button. without having to change the conductivity probe. This makes it very easy to switch applications without having to worry about recalibration.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eTo enhance accuracy and efficiency. MTC (Manual Temperature Compensation) is available using a knob on the front panel.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eFor the best protection in the field. the four ring potentiometric probe is made of rugged PVC. To access difficult areas. the probe is supplied with a 1 m (3.3') cable. The ratio between conductivity and TDS is factory set at 0.5.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 8734 is supplied with HI 76301D conductivity probe. HI 70032 1382 mg\/L (ppm) calibration solution sachet. battery. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man8734y_14_07_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0 to 199.9 mg\/L (ppm); 0 to 1999 mg\/L (ppm); 0.00 to 19.99 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L (ppm); 1 mg\/L (ppm); 0.01 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1% F.S. (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. 1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. 0 to 50°C (32 to 122°F) with ß=2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 76301D four ring conductivity probe with  DIN connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V \/ approximately 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e230 g (8.1 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","published_at":"2026-06-25T16:29:20+12:00","created_at":"2015-09-01T15:06:27+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters"],"price":78500,"price_min":78500,"price_max":78500,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857142405,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI8734","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 8734 TDS Meter with Multi-Range 0.0 to 19.99 g\/L (ppt).","public_title":null,"options":["Default Title"],"price":78500,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/tds-handmessgerat-mit-3-bereichen-1064_1-1_2015.jpeg?v=1443494802"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/tds-handmessgerat-mit-3-bereichen-1064_1-1_2015.jpeg?v=1443494802","options":["Title"],"media":[{"alt":"HANNA HI 8734 TDS Meter with Multi-Range 0.0 to 19.99 g\/L (ppt). - Acorn Scientific","id":21275246691,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/tds-handmessgerat-mit-3-bereichen-1064_1-1_2015.jpeg?v=1443494802"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/tds-handmessgerat-mit-3-bereichen-1064_1-1_2015.jpeg?v=1443494802","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: justify;\"\u003eHI 8734 has not only been specifically designed for the water conditioning industry. but particularly in the softening. demineralization. reverse osmosis and drinking water applications.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThree ranges of measurement ensure the highest accuracy possible. All three ranges can be executed at the touch of a button. without having to change the conductivity probe. This makes it very easy to switch applications without having to worry about recalibration.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eTo enhance accuracy and efficiency. MTC (Manual Temperature Compensation) is available using a knob on the front panel.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eFor the best protection in the field. the four ring potentiometric probe is made of rugged PVC. To access difficult areas. the probe is supplied with a 1 m (3.3') cable. The ratio between conductivity and TDS is factory set at 0.5.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 8734 is supplied with HI 76301D conductivity probe. HI 70032 1382 mg\/L (ppm) calibration solution sachet. battery. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man8734y_14_07_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0 to 199.9 mg\/L (ppm); 0 to 1999 mg\/L (ppm); 0.00 to 19.99 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L (ppm); 1 mg\/L (ppm); 0.01 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1% F.S. (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. 1 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. 0 to 50°C (32 to 122°F) with ß=2%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 76301D four ring conductivity probe with  DIN connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V \/ approximately 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e230 g (8.1 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e"}

HANNA HI 8734 TDS Meter with Multi-Range 0.0 to 19.99 g/L (ppt).

Product Description

HI 8734 has not only been specifically designed for the water conditioning industry. but particularly in the softening. demineralization. reverse osmosis and drinking water applications.

Three ranges of measurement ensure the highest accuracy possible. All three ranges can be executed at the touch of a button. without having to change the conductivity probe. This makes it very easy to switch applications without having to worry about recalibration.

To enhance accuracy and efficiency. MTC (Manual Temperature Compensation) is available using a knob on the front panel.

For the best protection in the field. the four ring potentiometric probe is made of rugged PVC. To access difficult areas. the probe is supplied with a 1 m (3.3') cable. The ratio between conductivity and TDS is factory set at 0.5.

 

Order Information:   HI 8734 is supplied with HI 76301D conductivity probe. HI 70032 1382 mg/L (ppm) calibration solution sachet. battery. instructions and rugged carrying case.

Product Manuals

  Manual: Download

Specification :

Range   0.0 to 199.9 mg/L (ppm); 0 to 1999 mg/L (ppm); 0.00 to 19.99 g/L (ppt)
Resolution   0.1 mg/L (ppm); 1 mg/L (ppm); 0.01 g/L (ppt)
Accuracy   ±1% F.S. (excluding probe error)
Calibration   manual. 1 point
Temperature Compensation   manual. 0 to 50°C (32 to 122°F) with ß=2%/°C
Probe   HI 76301D four ring conductivity probe with  DIN connector and 1 m (3.3’) cable (included)
Battery Type / Life   9V / approximately 100 hours of continuous use
Environment   0 to 50°C (32 to 122°F); RH max 100%
Dimensions   145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)
Weight   230 g (8.1 oz.)

 

This product is available upon request. Contact us for more information.