{"id":1582155717,"title":"HANNA HI 8936AN EC - Transmitter - 0 to 199.9 mS\/cm","handle":"hi8936an","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUtilizes HANNA’s potentiometric four-ring conductivity probe\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eDirect probe connection eliminates signal loss\u003c\/li\u003e\n\u003cli\u003eUse in conjunction with HI 7638 or HI 3001 platinum conductivity probes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 8936 is our redesigned conductivity transmitter that utilizes a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. This allows the transmitter to operate at peak performance at all times.\u003c\/p\u003e\n\u003cp\u003eTemperature effects are compensated for by utilizing both the built-in temperature sensor on the probe and the transmitter's ATC circuitry with a \u003cspan class=\"st\"\u003eβ\u003c\/span\u003e of 2%\/°C.\u003c\/p\u003e\n\u003cp\u003eDirect connection of the probe to the transmitter assures a positive electrical connection with no signal loss over long distances.\u003c\/p\u003e\n\u003cp\u003eHI 8936”L” versions allow easy verification and monitoring of measured values and is easier to calibrate and maintain.\u003c\/p\u003e\n\u003cp\u003eThe HI 8936 series requires external power to the 4-20 mA current loop.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e All HI 8936 models are supplied complete with instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Manual:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.hannainst.com\/manuals\/HI8931_03_2012.pdf\"\u003eHI 8936AL (Process Instrumentation)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.0 to 199.9 mS\/cm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @ 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±2% f.s. (excluding probe error)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emanual. two point. with offset and slope trimmers\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003efixed or automatic from 0 to 50°C (32 to 122°F) with ß=2%\/°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eHI 7635 for in-line applications (not included)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e4-20 mA. not isolated. max 500 Ohm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eIP65\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e12-30 VDC\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e165 x 110 x 71 mm (6.5 x 4.3 x 2.8’’)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1 kg (2.2 lb.)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2026-06-25T16:19:05+12:00","created_at":"2015-09-01T15:14:26+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters"],"price":41610,"price_min":41610,"price_max":41610,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857278405,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI8936AN","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 8936AN EC - Transmitter - 0 to 199.9 mS\/cm","public_title":null,"options":["Default Title"],"price":41610,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e827c466d89_2015.jpeg?v=1443495497"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e827c466d89_2015.jpeg?v=1443495497","options":["Title"],"media":[{"alt":"HANNA HI 8936AN EC - Transmitter - 0 to 199.9 mS\/cm - Acorn Scientific","id":21295759459,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e827c466d89_2015.jpeg?v=1443495497"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e827c466d89_2015.jpeg?v=1443495497","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUtilizes HANNA’s potentiometric four-ring conductivity probe\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eDirect probe connection eliminates signal loss\u003c\/li\u003e\n\u003cli\u003eUse in conjunction with HI 7638 or HI 3001 platinum conductivity probes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 8936 is our redesigned conductivity transmitter that utilizes a four-ring potentiometric probe. This probe is virtually immune to contamination by unclean solutions. This allows the transmitter to operate at peak performance at all times.\u003c\/p\u003e\n\u003cp\u003eTemperature effects are compensated for by utilizing both the built-in temperature sensor on the probe and the transmitter's ATC circuitry with a \u003cspan class=\"st\"\u003eβ\u003c\/span\u003e of 2%\/°C.\u003c\/p\u003e\n\u003cp\u003eDirect connection of the probe to the transmitter assures a positive electrical connection with no signal loss over long distances.\u003c\/p\u003e\n\u003cp\u003eHI 8936”L” versions allow easy verification and monitoring of measured values and is easier to calibrate and maintain.\u003c\/p\u003e\n\u003cp\u003eThe HI 8936 series requires external power to the 4-20 mA current loop.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e All HI 8936 models are supplied complete with instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Manual:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"http:\/\/www.hannainst.com\/manuals\/HI8931_03_2012.pdf\"\u003eHI 8936AL (Process Instrumentation)\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.0 to 199.9 mS\/cm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @ 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±2% f.s. (excluding probe error)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emanual. two point. with offset and slope trimmers\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003efixed or automatic from 0 to 50°C (32 to 122°F) with ß=2%\/°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eHI 7635 for in-line applications (not included)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e4-20 mA. not isolated. max 500 Ohm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eIP65\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e12-30 VDC\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e165 x 110 x 71 mm (6.5 x 4.3 x 2.8’’)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1 kg (2.2 lb.)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}
HANNA HI 8936AN EC - Transmitter - 0 to 199.9 mS/cm
Related Products
Biobase PH-210 Benchtop pH meter
$1,229.00 $1,695.00
Carbolite Heating element 200mm long
$799.00 $850.00
Carbolite Thermocouple for AAF11/3
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00














