{"id":1582157893,"title":"HANNA HI 903-02Karl Fischer Volumetric Titrator - 100ppm to 100%","handle":"hi903-02","description":"\u003cp\u003e\u003cstrong\u003ePrecision titrant delivery system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e40.000 step. piston dosing pump\u003c\/li\u003e\n\u003cli\u003eAccurate to 0.1%\u003c\/li\u003e\n\u003cli\u003eDelivers as little as 0.125 µL of titrant\u003c\/li\u003e\n\u003cli\u003ePrecision ground. 5 mL glass burette with PTFE plunger. PTFE burette tubing. and polyurethane tube jacketing (thermally insulating. light blocking)\u003c\/li\u003e\n\u003cli\u003eGlass anti-diffusion dispensing tip\u003c\/li\u003e\n\u003cli\u003eClip-Lock™ exchangeable burette system enables users to exchange reagent burettes in a matter of seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSealed solvent system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChange to fresh solvent in a matter of seconds without opening the titration vessel\u003c\/li\u003e\n\u003cli\u003eMinimizes exposure to ambient humidity. reducing titrant consumption and saving time\u003c\/li\u003e\n\u003cli\u003ePTFE solvent tubing is resistant to harsh KF solvents and titrants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBeaker top\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChemically-resistant reaction vessel cap and fittings\u003c\/li\u003e\n\u003cli\u003eQuick-remove sample port plug with replaceable silicone rubber septum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-diffusion burette tip\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDelivers titrant in high turbulence zone. ensuring rapid reaction\u003c\/li\u003e\n\u003cli\u003ePrevents unwanted diffusion of titrant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in stirrer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic. integrated magnetic stirrer adjustable from 200-2000 RPM\u003c\/li\u003e\n\u003cli\u003eOptical feedback for automatic speed control\u003c\/li\u003e\n\u003cli\u003eOptional external stirrer available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRechargeable indicating desiccant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents the ingress of ambient humidity into the sealed solvent system while maintaining full titrator functionality\u003c\/li\u003e\n\u003cli\u003eMinimizes changes to titrant titre\u003c\/li\u003e\n\u003cli\u003eIndicates when adsorption capacity is depleted\u003c\/li\u003e\n\u003cli\u003eRegenerates at 150°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePTFE bottle cap\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCaps fit any GL45-threaded bottle\u003c\/li\u003e\n\u003cli\u003eChemically resistant caps and fittings\u003c\/li\u003e\n\u003cli\u003eRemovable desiccant cartridges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Adaptable. High Accuracy Moisture Determination \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe HI 903 Karl Fischer Volumetric Titrator for moisture analysis is an extension of HANNA’s highly successful potentiometric titrator platform. The HI 903 combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring. sophisticated endpoint determination. dynamic dosing and background drift correction algorithms.\u003c\/p\u003e\n\u003cp\u003eThe result is an extremely adaptable titrator capable of titrating with superior accuracy and precision even for samples with low moisture content. The HI 903 dispenses the titrant. detects the endpoint and performs all necessary calculations automatically.\u003c\/p\u003e\n\u003cp\u003eThe HI 903 comes equipped with a solvent handling system to reduce cell conditioning time and can be connected directly to your laboratory balance via serial interface.\u003c\/p\u003e\n\u003cp\u003eThe HI 903’s powerful software and intuitive menus are easily navigated on the large. color LCD display making it simple to view results. Choose from included methods or develop a custom method for almost any application or sample type. Using a USB flash drive or connecting the titrator to the HI 900PC application. methods (standard and user) can be upgraded. stored or deleted. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Clip-Lock™ Exchangeable Burette System \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith Clip-Lock™. it only takes a couple of seconds to exchange the reagent burettes to perform a different titration.\u003c\/p\u003e\n\u003cp\u003eThe Clip-Lock™ exchangeable burette system prevents cross contamination while reducing loss of time and reagents. Burettes simply slide out for quick exchanges. and detaching the aspiration and dispensing tubes from the titrant bottles is easy.\u003c\/p\u003e\n\u003cp\u003eInterrupting an important cycle of analysis due to a malfunctioning burette is a thing of the past. With the HANNA Clip-Lock™ system you can simply substitute the burette and complete all your tests with the same titrant! Having several prepared burettes on hand will make the HANNA HI 903 one of the fastest and most versatile titration systems available.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 903-02 (230V) is supplied with dual platinum pin electrode. dosing pump. 5 mL burette assembly with tubing. air pump assembly with tubing. beaker and bottle top assemblies and all fittings. desiccant cartridges (4) with indicating desiccant. stir bar. waste bottle. calibration key. USB cable. power cable. HI 900PC application. USB flash drive. quality certificate. ISO 8655 burette compliance report and instruction manual binder.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man_HI903_10_10_2013.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e100 ppm to 100%\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1 ppm (0.0001%)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResult Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e%. ppm. mg\/g. µg\/g. mg. µg. mg\/mL. µg\/mL. mg\/pc. µg\/pc\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eliquid or solid\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetermination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ePre-Titration Conditioning\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eautomatic\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eBackground Drift Correction\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eautomatic or user selectable value\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eEndpoint Criteria\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003efixed mV persistence. relative drift stop or absolute drift stop\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eDosing\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003edynamic with optional pre-dispensing rate\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eResult Statistic\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emean. standard deviation\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClip Lock™\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eDosing Pump Resolution\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1\/40000 of the burette volume (0.125 µL per dose)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eDosing Pump Accuracy\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.1% of full burette volume\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSyringe\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e5 mL precision ground glass with PTFE plunger\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eValve\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emotor driven 3-way. PTFE liquid contact material\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTubing\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ePTFE with light block and thermal jacketing\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eDispensing Tip\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eglass. fixed position. anti-diffusing\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTitration Vessel\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003econical with operation volume between 50-150 mL\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSolvent Handling System\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003esealed system. integrated diaphragm air pump\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eType\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003edual platinum pin. polarization electrode\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eConnection\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eBNC\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ePolarization Current\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1. 2. 5. 10. 15. 20. 30 or 40 µA\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eVoltage Range\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e2 mV to 1000 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eVoltage Resolution\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy (@25ºC\/77ºF)\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.1 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Stirrer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eType\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emagnetic. optically regulated. digital stirrer\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSpeed\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e200-2000 rpm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e100 rpm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeripheral Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ePC\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eeasily view. transfer. print or delete methods and reports via HI900PC application\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eUSB Flash Drive\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eeasily upgrade software or transfer methods and reports between devices using a USB drive\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eLaboratory Analytical Balance\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eRS232 to connect any laboratory balance\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ePrinter\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eprint directly from the HI 903 to a printer via parallel port\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eMonitor\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003einstrument status and titrations can be viewed on a larger screen using any VGA compatible external monitor\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eKeyboard\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ealphanumeric text can be entered using an optional PS\/2 keyboard\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGraphic Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e5.7” (320 x 240 pixel) color LCD\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTitration Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eup to 100 (standard and user) methods\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eup to 100 complete titration reports and drift rate reports can be stored\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGLP Conformity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eGood Laboratory Practice and instrument data storage and printing\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eEnglish. Portuguese and Spanish\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eABS plastic and steel\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeypad\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epolycarbonate\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e“-01” model: 115VAC. 50\/60 Hz;\u003cbr\u003e“-02” model: 230VAC. 50\/60 Hz; \u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e10 to 40ºC. up to 95% RH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e-20 to 70ºC. up to 95% RH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e390 x 350 x 380 mm (15.3 x 13.8 x 14.9”)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eapproximately 10 kg (22 lbs.)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2026-06-25T16:18:59+12:00","created_at":"2015-09-01T15:14:41+12:00","vendor":"Hanna Instruments","type":"Other Lab Equipment","tags":["Manufacturer_Hanna Instruments"],"price":1280000,"price_min":1280000,"price_max":1280000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857283589,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI903-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 903-02Karl Fischer Volumetric Titrator - 100ppm to 100%","public_title":null,"options":["Default Title"],"price":1280000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/titreur-volumetrique-karl-fischer-2438_1-1_2015.jpeg?v=1443495539"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/titreur-volumetrique-karl-fischer-2438_1-1_2015.jpeg?v=1443495539","options":["Title"],"media":[{"alt":null,"id":21296382051,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/titreur-volumetrique-karl-fischer-2438_1-1_2015.jpeg?v=1443495539"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/titreur-volumetrique-karl-fischer-2438_1-1_2015.jpeg?v=1443495539","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cstrong\u003ePrecision titrant delivery system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e40.000 step. piston dosing pump\u003c\/li\u003e\n\u003cli\u003eAccurate to 0.1%\u003c\/li\u003e\n\u003cli\u003eDelivers as little as 0.125 µL of titrant\u003c\/li\u003e\n\u003cli\u003ePrecision ground. 5 mL glass burette with PTFE plunger. PTFE burette tubing. and polyurethane tube jacketing (thermally insulating. light blocking)\u003c\/li\u003e\n\u003cli\u003eGlass anti-diffusion dispensing tip\u003c\/li\u003e\n\u003cli\u003eClip-Lock™ exchangeable burette system enables users to exchange reagent burettes in a matter of seconds\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSealed solvent system\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChange to fresh solvent in a matter of seconds without opening the titration vessel\u003c\/li\u003e\n\u003cli\u003eMinimizes exposure to ambient humidity. reducing titrant consumption and saving time\u003c\/li\u003e\n\u003cli\u003ePTFE solvent tubing is resistant to harsh KF solvents and titrants\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBeaker top\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChemically-resistant reaction vessel cap and fittings\u003c\/li\u003e\n\u003cli\u003eQuick-remove sample port plug with replaceable silicone rubber septum\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAnti-diffusion burette tip\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDelivers titrant in high turbulence zone. ensuring rapid reaction\u003c\/li\u003e\n\u003cli\u003ePrevents unwanted diffusion of titrant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in stirrer\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic. integrated magnetic stirrer adjustable from 200-2000 RPM\u003c\/li\u003e\n\u003cli\u003eOptical feedback for automatic speed control\u003c\/li\u003e\n\u003cli\u003eOptional external stirrer available\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRechargeable indicating desiccant\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePrevents the ingress of ambient humidity into the sealed solvent system while maintaining full titrator functionality\u003c\/li\u003e\n\u003cli\u003eMinimizes changes to titrant titre\u003c\/li\u003e\n\u003cli\u003eIndicates when adsorption capacity is depleted\u003c\/li\u003e\n\u003cli\u003eRegenerates at 150°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePTFE bottle cap\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCaps fit any GL45-threaded bottle\u003c\/li\u003e\n\u003cli\u003eChemically resistant caps and fittings\u003c\/li\u003e\n\u003cli\u003eRemovable desiccant cartridges\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Adaptable. High Accuracy Moisture Determination \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe HI 903 Karl Fischer Volumetric Titrator for moisture analysis is an extension of HANNA’s highly successful potentiometric titrator platform. The HI 903 combines an ultra-high precision titrant delivery system with optically regulated magnetic stirring. sophisticated endpoint determination. dynamic dosing and background drift correction algorithms.\u003c\/p\u003e\n\u003cp\u003eThe result is an extremely adaptable titrator capable of titrating with superior accuracy and precision even for samples with low moisture content. The HI 903 dispenses the titrant. detects the endpoint and performs all necessary calculations automatically.\u003c\/p\u003e\n\u003cp\u003eThe HI 903 comes equipped with a solvent handling system to reduce cell conditioning time and can be connected directly to your laboratory balance via serial interface.\u003c\/p\u003e\n\u003cp\u003eThe HI 903’s powerful software and intuitive menus are easily navigated on the large. color LCD display making it simple to view results. Choose from included methods or develop a custom method for almost any application or sample type. Using a USB flash drive or connecting the titrator to the HI 900PC application. methods (standard and user) can be upgraded. stored or deleted. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Clip-Lock™ Exchangeable Burette System \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWith Clip-Lock™. it only takes a couple of seconds to exchange the reagent burettes to perform a different titration.\u003c\/p\u003e\n\u003cp\u003eThe Clip-Lock™ exchangeable burette system prevents cross contamination while reducing loss of time and reagents. Burettes simply slide out for quick exchanges. and detaching the aspiration and dispensing tubes from the titrant bottles is easy.\u003c\/p\u003e\n\u003cp\u003eInterrupting an important cycle of analysis due to a malfunctioning burette is a thing of the past. With the HANNA Clip-Lock™ system you can simply substitute the burette and complete all your tests with the same titrant! Having several prepared burettes on hand will make the HANNA HI 903 one of the fastest and most versatile titration systems available.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 903-02 (230V) is supplied with dual platinum pin electrode. dosing pump. 5 mL burette assembly with tubing. air pump assembly with tubing. beaker and bottle top assemblies and all fittings. desiccant cartridges (4) with indicating desiccant. stir bar. waste bottle. calibration key. USB cable. power cable. HI 900PC application. USB flash drive. quality certificate. ISO 8655 burette compliance report and instruction manual binder.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man_HI903_10_10_2013.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e100 ppm to 100%\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1 ppm (0.0001%)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResult Units\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e%. ppm. mg\/g. µg\/g. mg. µg. mg\/mL. µg\/mL. mg\/pc. µg\/pc\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eliquid or solid\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDetermination\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ePre-Titration Conditioning\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eautomatic\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eBackground Drift Correction\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eautomatic or user selectable value\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eEndpoint Criteria\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003efixed mV persistence. relative drift stop or absolute drift stop\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eDosing\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003edynamic with optional pre-dispensing rate\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eResult Statistic\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emean. standard deviation\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eClip Lock™\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eDosing Pump Resolution\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1\/40000 of the burette volume (0.125 µL per dose)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eDosing Pump Accuracy\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.1% of full burette volume\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSyringe\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e5 mL precision ground glass with PTFE plunger\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eValve\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emotor driven 3-way. PTFE liquid contact material\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTubing\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ePTFE with light block and thermal jacketing\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eDispensing Tip\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eglass. fixed position. anti-diffusing\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTitration Vessel\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003econical with operation volume between 50-150 mL\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSolvent Handling System\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003esealed system. integrated diaphragm air pump\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eType\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003edual platinum pin. polarization electrode\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eConnection\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eBNC\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ePolarization Current\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1. 2. 5. 10. 15. 20. 30 or 40 µA\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eVoltage Range\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e2 mV to 1000 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eVoltage Resolution\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eAccuracy (@25ºC\/77ºF)\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.1 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eExternal Stirrer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eType\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003emagnetic. optically regulated. digital stirrer\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSpeed\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e200-2000 rpm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eResolution\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e100 rpm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePeripheral Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ePC\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eeasily view. transfer. print or delete methods and reports via HI900PC application\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eUSB Flash Drive\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eeasily upgrade software or transfer methods and reports between devices using a USB drive\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eLaboratory Analytical Balance\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eRS232 to connect any laboratory balance\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ePrinter\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eprint directly from the HI 903 to a printer via parallel port\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eMonitor\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003einstrument status and titrations can be viewed on a larger screen using any VGA compatible external monitor\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eKeyboard\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003ealphanumeric text can be entered using an optional PS\/2 keyboard\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGraphic Display\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e5.7” (320 x 240 pixel) color LCD\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTitration Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eup to 100 (standard and user) methods\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Storage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eup to 100 complete titration reports and drift rate reports can be stored\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGLP Conformity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eGood Laboratory Practice and instrument data storage and printing\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLanguages\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eEnglish. Portuguese and Spanish\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eABS plastic and steel\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eKeypad\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epolycarbonate\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e“-01” model: 115VAC. 50\/60 Hz;\u003cbr\u003e“-02” model: 230VAC. 50\/60 Hz; \u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e10 to 40ºC. up to 95% RH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e-20 to 70ºC. up to 95% RH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e390 x 350 x 380 mm (15.3 x 13.8 x 14.9”)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eapproximately 10 kg (22 lbs.)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}
HANNA HI 903-02Karl Fischer Volumetric Titrator - 100ppm to 100%
Related Products
HANNA BL983320-1 Conductivity Mini Controller @ 199.9 µS/cm
$350.00 $465.00














