{"id":2012145541,"title":"HANNA HI 96708C Nitrite HR 0-150 mg\/L - Photometer with Cal kits \u0026 Casing","handle":"hi96708c","description":"\u003cp\u003eNitrites are an intermediate product in the nitrogen cycle and are produced by ammonia oxidation with water. or even originate in industrial waste directly. They must not be present in drinking water.\u003c\/p\u003e\n\u003cp\u003eThe HI 96708 meter measures the nitrite  content in water and wastewater in the 0 to 150 mg\/L (ppm) range.\u003c\/p\u003e\n\u003cp\u003eThis meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e  \u003cstrong\u003eHI 96708C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96708_14_12_2010.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 150 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±4 mg\/L ±4% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003esilicon photocell with narrow band interference filter @ 575 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V \/ approx. 40 hours of continuous use; auto-off after 10 minutes of non use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ferrous Sulfate method; The reaction between nitrite and the reagent causes a greenish-brown tint in the sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2026-06-25T15:26:30+12:00","created_at":"2015-09-04T15:10:15+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":65550,"price_min":65550,"price_max":65550,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5764101573,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96708C","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 96708C Nitrite HR 0-150 mg\/L - Photometer with Cal kits \u0026 Casing","public_title":null,"options":["Default Title"],"price":65550,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015_9306f485-e273-418d-8e9b-47129fe793e3.jpeg?v=1443494569","\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-nitrit-bis-150-mgl-1303_1-151cfe213d1e6e_2015.jpeg?v=1443494569"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015_9306f485-e273-418d-8e9b-47129fe793e3.jpeg?v=1443494569","options":["Title"],"media":[{"alt":null,"id":25181651043,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015_9306f485-e273-418d-8e9b-47129fe793e3.jpeg?v=1443494569"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfe05fc7004_2015_9306f485-e273-418d-8e9b-47129fe793e3.jpeg?v=1443494569","width":800},{"alt":null,"id":25181683811,"position":2,"preview_image":{"aspect_ratio":1.028,"height":800,"width":822,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-nitrit-bis-150-mgl-1303_1-151cfe213d1e6e_2015.jpeg?v=1443494569"},"aspect_ratio":1.028,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-nitrit-bis-150-mgl-1303_1-151cfe213d1e6e_2015.jpeg?v=1443494569","width":822}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eNitrites are an intermediate product in the nitrogen cycle and are produced by ammonia oxidation with water. or even originate in industrial waste directly. They must not be present in drinking water.\u003c\/p\u003e\n\u003cp\u003eThe HI 96708 meter measures the nitrite  content in water and wastewater in the 0 to 150 mg\/L (ppm) range.\u003c\/p\u003e\n\u003cp\u003eThis meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e  \u003cstrong\u003eHI 96708C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96708_14_12_2010.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 150 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±4 mg\/L ±4% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003esilicon photocell with narrow band interference filter @ 575 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V \/ approx. 40 hours of continuous use; auto-off after 10 minutes of non use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ferrous Sulfate method; The reaction between nitrite and the reagent causes a greenish-brown tint in the sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}

HANNA HI 96708C Nitrite HR 0-150 mg/L - Photometer with Cal kits & Casing

Product Description

Nitrites are an intermediate product in the nitrogen cycle and are produced by ammonia oxidation with water. or even originate in industrial waste directly. They must not be present in drinking water.

The HI 96708 meter measures the nitrite  content in water and wastewater in the 0 to 150 mg/L (ppm) range.

This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.

 

Order Information:  HI 96708C includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.

Product Manuals

  Manual: Download

Specification :

Range   0 to 150 mg/L
Resolution   1 mg/L
Accuracy   ±4 mg/L ±4% of reading @ 25°C
Light Source   Tungsten Lamp
Light Detection   silicon photocell with narrow band interference filter @ 575 nm
Battery Type / Life   9V / approx. 40 hours of continuous use; auto-off after 10 minutes of non use
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight   360 g (12.7 oz.)
Method   Adaptation of the ferrous Sulfate method; The reaction between nitrite and the reagent causes a greenish-brown tint in the sample

 