Email info@acornsci.com for orders and inquiries.

{"id":1582146693,"title":"HANNA HI 96711C Chlorine Free \u0026 Total 0.00 - 5.00 mg\/l - Photometer with Cal kit \u0026 Casing","handle":"hi96711c","description":"\u003cp\u003eThe HI 96711 meter measures the free and total chlorine (Cl\u003csub\u003e2\u003c\/sub\u003e) content in water and wastewater.\u003c\/p\u003e\n\u003cp\u003eThis meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\n\u003cp\u003eChlorine is integrated into water supplies in it’s molecular form for the purpose of destroying unwanted microorganisms.  Once introduced to the water. chlorine will form into three different forms; free chlorine. hypochlorous acid. and hypochlorous ions.  Free chlorine will combine itself with ammonia and nitrogen compounds. creating combined chlorine. When chlorine and ammonia combine. it creates chloramines (monochloramine. dichloramine. and nitrogen trichloride. Proper testing should be administered when chlorinating any water supply. as potentially harmful compounds such as chloroform may be formed. N. N-diethyl-p-phenylenediamine (DPD) as well as other methods are available for measuring total residual chlorine.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96711C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96711_09_12_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eFree Chlorine\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTotal Chlorine\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L from 0.00 to 3.50 mg\/L; 0.10 mg\/L above 3.50 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery; auto-off: after ten minutes of non-use in measurement mode; after one hour  of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of the USEPA method 330.5 and Standard Method 4500-Cl G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2026-06-25T16:19:22+12:00","created_at":"2015-09-01T15:13:38+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":68590,"price_min":68590,"price_max":68590,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857262469,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96711C","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 96711C Chlorine Free \u0026 Total 0.00 - 5.00 mg\/l - Photometer with Cal kit \u0026 Casing","public_title":null,"options":["Default Title"],"price":68590,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e52999f09da_2015.jpeg?v=1443495409"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e52999f09da_2015.jpeg?v=1443495409","options":["Title"],"media":[{"alt":null,"id":21293924451,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e52999f09da_2015.jpeg?v=1443495409"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e52999f09da_2015.jpeg?v=1443495409","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe HI 96711 meter measures the free and total chlorine (Cl\u003csub\u003e2\u003c\/sub\u003e) content in water and wastewater.\u003c\/p\u003e\n\u003cp\u003eThis meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\n\u003cp\u003eChlorine is integrated into water supplies in it’s molecular form for the purpose of destroying unwanted microorganisms.  Once introduced to the water. chlorine will form into three different forms; free chlorine. hypochlorous acid. and hypochlorous ions.  Free chlorine will combine itself with ammonia and nitrogen compounds. creating combined chlorine. When chlorine and ammonia combine. it creates chloramines (monochloramine. dichloramine. and nitrogen trichloride. Proper testing should be administered when chlorinating any water supply. as potentially harmful compounds such as chloroform may be formed. N. N-diethyl-p-phenylenediamine (DPD) as well as other methods are available for measuring total residual chlorine.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96711C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96711_09_12_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eFree Chlorine\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTotal Chlorine\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L from 0.00 to 3.50 mg\/L; 0.10 mg\/L above 3.50 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery; auto-off: after ten minutes of non-use in measurement mode; after one hour  of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of the USEPA method 330.5 and Standard Method 4500-Cl G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}

HANNA HI 96711C Chlorine Free & Total 0.00 - 5.00 mg/l - Photometer with Cal kit & Casing

Product Description

The HI 96711 meter measures the free and total chlorine (Cl2) content in water and wastewater.

This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.

Chlorine is integrated into water supplies in it’s molecular form for the purpose of destroying unwanted microorganisms.  Once introduced to the water. chlorine will form into three different forms; free chlorine. hypochlorous acid. and hypochlorous ions.  Free chlorine will combine itself with ammonia and nitrogen compounds. creating combined chlorine. When chlorine and ammonia combine. it creates chloramines (monochloramine. dichloramine. and nitrogen trichloride. Proper testing should be administered when chlorinating any water supply. as potentially harmful compounds such as chloroform may be formed. N. N-diethyl-p-phenylenediamine (DPD) as well as other methods are available for measuring total residual chlorine.

 

Order Information: HI 96711C includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.

Product Manuals

  Manual: Download

Specification :

Range Free Chlorine 0.00 to 5.00 mg/L
Range Total Chlorine 0.00 to 5.00 mg/L
Resolution   0.01 mg/L from 0.00 to 3.50 mg/L; 0.10 mg/L above 3.50 mg/L
Accuracy   ±0.03 mg/L ±3% of reading @ 25°C
Light Source   Tungsten lamp
Light Detection   Silicon Photocell
Power Supply   9V battery; auto-off: after ten minutes of non-use in measurement mode; after one hour  of non-use in calibration mode; with last reading reminder
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight   360 g (12.7 oz.)
Method   adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G

 

This product is available upon request. Contact us for more information.