Email info@acornsci.com for orders and inquiries.

{"id":1582074309,"title":"HANNA HI 96717 Phosphate HR 0.0-30.0 mg\/L - Photometer mobile","handle":"hi96717","description":"\u003cp\u003ePhosphates are particularly important for the growth and development of plant roots. and hence are one of the most common fertilizers used in agriculture.\u003c\/p\u003e\n\u003cp\u003ePhosphates are also utilized in detergents and are needed. in small quantities. for heating systems. However. high concentrations of phosphates can cause environmental pollution as they are a primary cause of eutrophication.\u003c\/p\u003e\n\u003cp\u003eFor these reasons. it is necessary to closely monitor the phosphate levels present in both municipal and industrial waste water.\u003c\/p\u003e\n\u003cp\u003eThe HI 96717 measures the phosphate (PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3–\u003c\/sup\u003e) content in water samples in the 0.0 to 30.0 mg\/L (ppm) range. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96717\u003c\/strong\u003e are supplied with sample cuvettes with caps (2). 9V battery and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96717_19_01_11.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1.0 mg\/L ±4% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAmino Acid Method. adapted from Standard Method for the Examination of Water and Wastewater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Shut off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e","published_at":"2026-06-25T16:30:06+12:00","created_at":"2015-09-01T15:03:19+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":40660,"price_min":40660,"price_max":40660,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857070533,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96717","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 96717 Phosphate HR 0.0-30.0 mg\/L - Photometer mobile","public_title":null,"options":["Default Title"],"price":40660,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-phosphat-bis-300-mgl-1329_1-1_2015.jpeg?v=1443494573"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-phosphat-bis-300-mgl-1329_1-1_2015.jpeg?v=1443494573","options":["Title"],"media":[{"alt":"HI 96717 Phosphate HR 0.0-30.0 mg\/L - Photometer mobile - Acorn Scientific","id":21268693091,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-phosphat-bis-300-mgl-1329_1-1_2015.jpeg?v=1443494573"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-phosphat-bis-300-mgl-1329_1-1_2015.jpeg?v=1443494573","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003ePhosphates are particularly important for the growth and development of plant roots. and hence are one of the most common fertilizers used in agriculture.\u003c\/p\u003e\n\u003cp\u003ePhosphates are also utilized in detergents and are needed. in small quantities. for heating systems. However. high concentrations of phosphates can cause environmental pollution as they are a primary cause of eutrophication.\u003c\/p\u003e\n\u003cp\u003eFor these reasons. it is necessary to closely monitor the phosphate levels present in both municipal and industrial waste water.\u003c\/p\u003e\n\u003cp\u003eThe HI 96717 measures the phosphate (PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3–\u003c\/sup\u003e) content in water samples in the 0.0 to 30.0 mg\/L (ppm) range. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96717\u003c\/strong\u003e are supplied with sample cuvettes with caps (2). 9V battery and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96717_19_01_11.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1.0 mg\/L ±4% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAmino Acid Method. adapted from Standard Method for the Examination of Water and Wastewater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Shut off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\n\u003cbr\u003e \u003c\/div\u003e"}

HANNA HI 96717 Phosphate HR 0.0-30.0 mg/L - Photometer mobile

Product Description

Phosphates are particularly important for the growth and development of plant roots. and hence are one of the most common fertilizers used in agriculture.

Phosphates are also utilized in detergents and are needed. in small quantities. for heating systems. However. high concentrations of phosphates can cause environmental pollution as they are a primary cause of eutrophication.

For these reasons. it is necessary to closely monitor the phosphate levels present in both municipal and industrial waste water.

The HI 96717 measures the phosphate (PO43–) content in water samples in the 0.0 to 30.0 mg/L (ppm) range. 

 

Order Information: HI 96717 are supplied with sample cuvettes with caps (2). 9V battery and instruction manual.

Product Manuals

  Manual: Download

Specification :

Range   0.0 to 30.0 mg/L
Resolution   0.1 mg/L
Accuracy   ±1.0 mg/L ±4% of reading @ 25°C
Light Source   Tungsten lamp
Light Detector   Silicon photocell with narrow band interference filter @ 525 nm
Method   Amino Acid Method. adapted from Standard Method for the Examination of Water and Wastewater
Environment   0 to 50°C (32 to 122°F); max 95% RH non-condensing
Power Supply   9V battery
Auto-Shut off   after ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder
Dimensions   192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight   360 g (12.7 oz.)

 

This product is available upon request. Contact us for more information.