{"id":2012147013,"title":"HANNA HI96726C Nickel HR 0.00-7.00 mg\/L - Photometer with Cal kits \u0026 Casing","handle":"hi96726c","description":"\u003cp\u003eNickel is commonly utilized by the electroplating industry in processes utilizing stainless steel. cobalt or nickel alloys.\u003c\/p\u003e\u003cp\u003eNickel is also used in batteries. fuel cells and hydrogenation of vegetable oils in the food industry.\u003c\/p\u003e\u003cp\u003eThe HI 96726 measures the Nickel content in water and wastewater. This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\u003cp\u003eThe cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both. the measurement and the calibration (zeroing) cuvettes. are optically identical to provide the same measurement conditions.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96726C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96726_21_12_2010.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/man96726_21_12_2010.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 7.00 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.07 g\/L ±4% @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 575 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e(1) 9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the photometric method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e","published_at":"2026-06-25T15:26:28+12:00","created_at":"2015-09-04T15:10:34+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":63000,"price_min":63000,"price_max":63000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5764113797,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96726C","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI96726C Nickel HR 0.00-7.00 mg\/L - Photometer with Cal kits \u0026 Casing","public_title":null,"options":["Default Title"],"price":63000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_f1cd375e-67b1-4c6d-b392-8450386794d8.jpeg?v=1443494599","\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-nickel-bis-700-gl-1354_1-151d00248d725d_2015.jpeg?v=1443494599"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_f1cd375e-67b1-4c6d-b392-8450386794d8.jpeg?v=1443494599","options":["Title"],"media":[{"alt":"HANNA HI96726C Nickel HR 0.00-7.00 mg\/L - Photometer with Cal kits \u0026 Casing - Acorn Scientific","id":25182240867,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_f1cd375e-67b1-4c6d-b392-8450386794d8.jpeg?v=1443494599"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_f1cd375e-67b1-4c6d-b392-8450386794d8.jpeg?v=1443494599","width":800},{"alt":"HANNA HI96726C Nickel HR 0.00-7.00 mg\/L - Photometer with Cal kits \u0026 Casing - Acorn Scientific","id":25182273635,"position":2,"preview_image":{"aspect_ratio":1.028,"height":800,"width":822,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-nickel-bis-700-gl-1354_1-151d00248d725d_2015.jpeg?v=1443494599"},"aspect_ratio":1.028,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-nickel-bis-700-gl-1354_1-151d00248d725d_2015.jpeg?v=1443494599","width":822}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eNickel is commonly utilized by the electroplating industry in processes utilizing stainless steel. cobalt or nickel alloys.\u003c\/p\u003e\u003cp\u003eNickel is also used in batteries. fuel cells and hydrogenation of vegetable oils in the food industry.\u003c\/p\u003e\u003cp\u003eThe HI 96726 measures the Nickel content in water and wastewater. This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\u003cp\u003eThe cuvette has a very important role because it is an optical element and thus requires particular attention. It is important that both. the measurement and the calibration (zeroing) cuvettes. are optically identical to provide the same measurement conditions.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96726C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man96726_21_12_2010.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/man96726_21_12_2010.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003cbr\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 7.00 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.07 g\/L ±4% @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 575 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e(1) 9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 minutes of non-use in measurement mode; after 1 hour of non-use in calibration mode; with last reading reminder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the photometric method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e"}
HANNA HI96726C Nickel HR 0.00-7.00 mg/L - Photometer with Cal kits & Casing
Related Products
Biobase PH-210 Benchtop pH meter
$1,229.00 $1,695.00
Carbolite Heating element 200mm long
$799.00 $850.00
Carbolite Thermocouple for AAF11/3
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00














