Email info@acornsci.com for orders and inquiries.

{"id":2012148037,"title":"HANNA HI96747C Copper LR 0.000 - 1.500 mg\/L - Photometer with Cal kit \u0026 Casing","handle":"hi96747c","description":"\u003cp\u003eHI 96747 is a auto-diagnostic photometer engineered to measure a wide range of copper concentrations. Due to the specially formulated powder reagent with long-term stability. copper analysis is possible even where iron and calcium is present. This photometer does not work in saltwater.\u003c\/p\u003e\u003cp\u003eBoth meters use an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit a cuvette with a larger neck making it easier to add both sample and reagents. The cuvette is made from special optical glass to obtain best results.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96747C\u003c\/strong\u003e includes sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96747_04_07_2011.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/ist96747_04_07_2011.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.500 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L for measurement; 0.01 mg\/L for calibration and validation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.010 mg\/L ±5% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003etungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003esilicon photocell with narrow band interference filter @ 560 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); Max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Shut-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour  of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of the USEPA approved bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e","published_at":"2026-06-25T15:26:25+12:00","created_at":"2015-09-04T15:10:47+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":63000,"price_min":63000,"price_max":63000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5764116165,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96747C","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI96747C Copper LR 0.000 - 1.500 mg\/L - Photometer with Cal kit \u0026 Casing","public_title":null,"options":["Default Title"],"price":63000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_8ffeb3dd-ebc3-40c9-b915-d7de1a22ad18.jpeg?v=1443494616","\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-kupfer-bis-1500-mgl-1396_1-151d011a0beea4_2015.jpeg?v=1443494616"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_8ffeb3dd-ebc3-40c9-b915-d7de1a22ad18.jpeg?v=1443494616","options":["Title"],"media":[{"alt":null,"id":25182634083,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_8ffeb3dd-ebc3-40c9-b915-d7de1a22ad18.jpeg?v=1443494616"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_8ffeb3dd-ebc3-40c9-b915-d7de1a22ad18.jpeg?v=1443494616","width":800},{"alt":null,"id":25182666851,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-kupfer-bis-1500-mgl-1396_1-151d011a0beea4_2015.jpeg?v=1443494616"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-kupfer-bis-1500-mgl-1396_1-151d011a0beea4_2015.jpeg?v=1443494616","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eHI 96747 is a auto-diagnostic photometer engineered to measure a wide range of copper concentrations. Due to the specially formulated powder reagent with long-term stability. copper analysis is possible even where iron and calcium is present. This photometer does not work in saltwater.\u003c\/p\u003e\u003cp\u003eBoth meters use an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit a cuvette with a larger neck making it easier to add both sample and reagents. The cuvette is made from special optical glass to obtain best results.\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96747C\u003c\/strong\u003e includes sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96747_04_07_2011.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/ist96747_04_07_2011.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.500 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L for measurement; 0.01 mg\/L for calibration and validation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.010 mg\/L ±5% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003etungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003esilicon photocell with narrow band interference filter @ 560 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); Max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Shut-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour  of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eadaptation of the USEPA approved bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e"}

HANNA HI96747C Copper LR 0.000 - 1.500 mg/L - Photometer with Cal kit & Casing

Product Description

HI 96747 is a auto-diagnostic photometer engineered to measure a wide range of copper concentrations. Due to the specially formulated powder reagent with long-term stability. copper analysis is possible even where iron and calcium is present. This photometer does not work in saltwater.

Both meters use an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit a cuvette with a larger neck making it easier to add both sample and reagents. The cuvette is made from special optical glass to obtain best results.

 

 

Order Information: HI 96747C includes sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.

Product Manuals

  Manual: Download

Specification :

Range   0.000 to 1.500 mg/L
Resolution   0.001 mg/L for measurement; 0.01 mg/L for calibration and validation
Accuracy   ±0.010 mg/L ±5% of reading @ 25°C
Light Source   tungsten lamp
Light Detector   silicon photocell with narrow band interference filter @ 560 nm
Environment   0 to 50°C (32 to 122°F); Max 95% RH non-condensing
Power Supply   9V battery
Auto Shut-off   after ten minutes of non-use in measurement mode; after one hour  of non-use in calibration mode; with last reading reminder
Dimensions   192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight   360 g (12.7 oz.)
Method   adaptation of the USEPA approved bicinchoninate method


This product is available upon request. Contact us for more information.