Email info@acornsci.com for orders and inquiries.

{"id":1582071493,"title":"HANNA HI 96822 Seawater Analysis - Digital Refractometer Portable","handle":"hi96822","description":"\u003cul\u003e\n\u003cli\u003eThe dual-level LCD displays measurement and temperature readings simultaneously\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation for accurate measurements\u003c\/li\u003e\n\u003cli\u003eEasy measurement; place a few drops of the sample in the well and press the READ key\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.\u003c\/li\u003e\n\u003cli\u003eIP65 water protection; built to perform under harsh laboratory and field conditions.\u003c\/li\u003e\n\u003cli\u003eQuick. accurate results. readings are displayed in approximately 1.5 seconds.\u003c\/li\u003e\n\u003cli\u003eSingle point calibration with distilled or deionized water\u003c\/li\u003e\n\u003cli\u003eSmall sample size. can be as small as 2 metric drops.\u003c\/li\u003e\n\u003cli\u003eAutomatic shut-off after three minutes of non-use\u003c\/li\u003e\n\u003cli\u003eStainless steel sample well. easy to clean and corrosion resistant\u003c\/li\u003e\n\u003cli\u003eABS thermoplastic casing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHANNA‘s HI?96822 Digital Refractometer is a rugged. portable. water resistant device that utilizes the measurement of the refractive index to determine the salinity of natural and artificial seawater. ocean water or brackish intermediates. The HI?96822 reflects HANNA‘s years of experience as a manufacturer of analytical instruments. This digital refractometer eliminates the uncertainty associated with mechanical refractometers and is durable and compact enough to be used at home. in the lab and out in the field.\u003c\/p\u003e\n\u003cp\u003eThe HI 96822 is an optical device that is quick and easy to use. After a simple user calibration with distilled or deionized water. a seawater sample can be introduced into the sample well.\u003c\/p\u003e\n\u003cp\u003eWithin seconds. the refractive index and temperature are measured and converted into one of 3 popular measurement units: Practical Salinity Units (PSU). salinity in parts per thousand (ppt). or specific gravity (S.G. (20\/20)). All conversion algorithms are based upon respected scientific publications using the physical properties of seawater (not sodium chloride).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Importance of Salinity Measurement Throughout a Variety of Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSalinity is a critical measurement in many applications. such as aquaculture. environmental monitoring. aquariums. desalination plants. well water. and many more. Until now. the available technology to measure salinity has relied on mechanical instruments. such as hydrometers and ocular refractometers. or on high-tech conductivity meters.  While easy to use. ocular refractometers can be difficult to get a accurate reading from and are highly susceptible to changes in temperature.  Hydrometers. though inexpensive. are clumsy and inaccurate.  Conductivity meters that convert to salinity can be cost-prohibitive. \u003c\/p\u003e\n\u003cp\u003eThe HANNA HI 96822 is the solution to all these issues.  It is lightweight. easy to use. cost-efficient. and is extremely accurate.  With the ability to read in all the three of the most widely used salinity units (PSU. ppt. and specific gravity). it is the ideal instrument for any application.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 96822 is supplied with battery and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_96822.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003ePSU\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eppt\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 150\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity (20\/20)\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.000 to 1.114\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 80°C (32 to 176°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003ePSU\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eppt\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity (20\/20)\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.001\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (0.1°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003ePSU\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eppt\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity (20\/20)\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.002\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.3°C (0.5°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic between 10 and 40°C (50 to 104°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eapproximately 1.5 seconds\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Sample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e100 µL (to cover prism totally)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eyellow LED\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Cell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003estainless steel ring and flint glass prism\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eafter three minutes of non-use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eIP 65\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Battery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e9V \/ approximately 5000 readings\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7”) \/ 420 g (14.8 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2026-06-25T16:31:08+12:00","created_at":"2015-09-01T15:02:57+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Refractometer"],"price":34000,"price_min":34000,"price_max":34000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857052741,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96822","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 96822 Seawater Analysis - Digital Refractometer Portable","public_title":null,"options":["Default Title"],"price":34000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/digitalrefraktometer-fur-salzgehalt-meerwasser-1442_1-1_2015.jpeg?v=1443494485"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/digitalrefraktometer-fur-salzgehalt-meerwasser-1442_1-1_2015.jpeg?v=1443494485","options":["Title"],"media":[{"alt":"HI 96822 Seawater Analysis - Digital Refractometer Portable - Acorn Scientific","id":21267808355,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/digitalrefraktometer-fur-salzgehalt-meerwasser-1442_1-1_2015.jpeg?v=1443494485"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/digitalrefraktometer-fur-salzgehalt-meerwasser-1442_1-1_2015.jpeg?v=1443494485","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli\u003eThe dual-level LCD displays measurement and temperature readings simultaneously\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation for accurate measurements\u003c\/li\u003e\n\u003cli\u003eEasy measurement; place a few drops of the sample in the well and press the READ key\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.\u003c\/li\u003e\n\u003cli\u003eIP65 water protection; built to perform under harsh laboratory and field conditions.\u003c\/li\u003e\n\u003cli\u003eQuick. accurate results. readings are displayed in approximately 1.5 seconds.\u003c\/li\u003e\n\u003cli\u003eSingle point calibration with distilled or deionized water\u003c\/li\u003e\n\u003cli\u003eSmall sample size. can be as small as 2 metric drops.\u003c\/li\u003e\n\u003cli\u003eAutomatic shut-off after three minutes of non-use\u003c\/li\u003e\n\u003cli\u003eStainless steel sample well. easy to clean and corrosion resistant\u003c\/li\u003e\n\u003cli\u003eABS thermoplastic casing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHANNA‘s HI?96822 Digital Refractometer is a rugged. portable. water resistant device that utilizes the measurement of the refractive index to determine the salinity of natural and artificial seawater. ocean water or brackish intermediates. The HI?96822 reflects HANNA‘s years of experience as a manufacturer of analytical instruments. This digital refractometer eliminates the uncertainty associated with mechanical refractometers and is durable and compact enough to be used at home. in the lab and out in the field.\u003c\/p\u003e\n\u003cp\u003eThe HI 96822 is an optical device that is quick and easy to use. After a simple user calibration with distilled or deionized water. a seawater sample can be introduced into the sample well.\u003c\/p\u003e\n\u003cp\u003eWithin seconds. the refractive index and temperature are measured and converted into one of 3 popular measurement units: Practical Salinity Units (PSU). salinity in parts per thousand (ppt). or specific gravity (S.G. (20\/20)). All conversion algorithms are based upon respected scientific publications using the physical properties of seawater (not sodium chloride).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe Importance of Salinity Measurement Throughout a Variety of Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSalinity is a critical measurement in many applications. such as aquaculture. environmental monitoring. aquariums. desalination plants. well water. and many more. Until now. the available technology to measure salinity has relied on mechanical instruments. such as hydrometers and ocular refractometers. or on high-tech conductivity meters.  While easy to use. ocular refractometers can be difficult to get a accurate reading from and are highly susceptible to changes in temperature.  Hydrometers. though inexpensive. are clumsy and inaccurate.  Conductivity meters that convert to salinity can be cost-prohibitive. \u003c\/p\u003e\n\u003cp\u003eThe HANNA HI 96822 is the solution to all these issues.  It is lightweight. easy to use. cost-efficient. and is extremely accurate.  With the ability to read in all the three of the most widely used salinity units (PSU. ppt. and specific gravity). it is the ideal instrument for any application.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 96822 is supplied with battery and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_96822.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003ePSU\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eppt\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 150\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity (20\/20)\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.000 to 1.114\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 80°C (32 to 176°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003ePSU\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eppt\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity (20\/20)\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.001\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (0.1°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003ePSU\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eppt\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSpecific Gravity (20\/20)\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.002\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.3°C (0.5°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic between 10 and 40°C (50 to 104°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eapproximately 1.5 seconds\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMinimum Sample Volume\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e100 µL (to cover prism totally)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eyellow LED\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Cell\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003estainless steel ring and flint glass prism\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eafter three minutes of non-use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure Rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eIP 65\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Battery Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e9V \/ approximately 5000 readings\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7”) \/ 420 g (14.8 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

HANNA HI 96822 Seawater Analysis - Digital Refractometer Portable

Product Description
  • The dual-level LCD displays measurement and temperature readings simultaneously
  • Automatic Temperature Compensation for accurate measurements
  • Easy measurement; place a few drops of the sample in the well and press the READ key
  • BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.
  • IP65 water protection; built to perform under harsh laboratory and field conditions.
  • Quick. accurate results. readings are displayed in approximately 1.5 seconds.
  • Single point calibration with distilled or deionized water
  • Small sample size. can be as small as 2 metric drops.
  • Automatic shut-off after three minutes of non-use
  • Stainless steel sample well. easy to clean and corrosion resistant
  • ABS thermoplastic casing

 

HANNA‘s HI?96822 Digital Refractometer is a rugged. portable. water resistant device that utilizes the measurement of the refractive index to determine the salinity of natural and artificial seawater. ocean water or brackish intermediates. The HI?96822 reflects HANNA‘s years of experience as a manufacturer of analytical instruments. This digital refractometer eliminates the uncertainty associated with mechanical refractometers and is durable and compact enough to be used at home. in the lab and out in the field.

The HI 96822 is an optical device that is quick and easy to use. After a simple user calibration with distilled or deionized water. a seawater sample can be introduced into the sample well.

Within seconds. the refractive index and temperature are measured and converted into one of 3 popular measurement units: Practical Salinity Units (PSU). salinity in parts per thousand (ppt). or specific gravity (S.G. (20/20)). All conversion algorithms are based upon respected scientific publications using the physical properties of seawater (not sodium chloride).

The Importance of Salinity Measurement Throughout a Variety of Applications

Salinity is a critical measurement in many applications. such as aquaculture. environmental monitoring. aquariums. desalination plants. well water. and many more. Until now. the available technology to measure salinity has relied on mechanical instruments. such as hydrometers and ocular refractometers. or on high-tech conductivity meters.  While easy to use. ocular refractometers can be difficult to get a accurate reading from and are highly susceptible to changes in temperature.  Hydrometers. though inexpensive. are clumsy and inaccurate.  Conductivity meters that convert to salinity can be cost-prohibitive. 

The HANNA HI 96822 is the solution to all these issues.  It is lightweight. easy to use. cost-efficient. and is extremely accurate.  With the ability to read in all the three of the most widely used salinity units (PSU. ppt. and specific gravity). it is the ideal instrument for any application.

 

Order Information:   HI 96822 is supplied with battery and instruction manual.

Product Manuals

  Manual: Download

Specification

Range PSU 0 to 50
  ppt 0 to 150
  Specific Gravity (20/20) 1.000 to 1.114
  Temperature 0 to 80°C (32 to 176°F)
Resolution PSU 1
  ppt 1
  Specific Gravity (20/20) 0.001
  Temperature 0.1°C (0.1°F)
Accuracy (@20°C) PSU ±2
  ppt ±2
  Specific Gravity (20/20) ±0.002
  Temperature ±0.3°C (0.5°F)
Temperature Compensation   automatic between 10 and 40°C (50 to 104°F)
Measurement Time   approximately 1.5 seconds
Minimum Sample Volume   100 µL (to cover prism totally)
Light Source   yellow LED
Sample Cell   stainless steel ring and flint glass prism
Auto-off   after three minutes of non-use
Enclosure Rating   IP 65
Battery Type / Battery Life   9V / approximately 5000 readings
Dimensions / Weight   192 x 104 x 69 mm (7.6 x 4.1 x 2.7”) / 420 g (14.8 oz.)