{"id":2012158341,"title":"HANNA HI 99161 FOODCARE pH Meter \/ Food and Dairy (HACCP Compliant)","handle":"hi99161","description":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eEasy to clean and keep clean\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eSpecialized dairy electrode\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eMulti-level LCD display\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eOn-screen tutorial messages for calibration and set-up\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic one or two point calibration\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBattery % displayed on startup.\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eCompact. heavy-duty. and waterproof\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eMonitoring pH in dairy processes is critical to ensure the quality of products.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe \u003cstrong\u003eHI 99161\u003c\/strong\u003e is a portable. pH and temperature meter is specifically designed for dairy applications.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eFC 202D pH electrode features a rugged. easy to clean. PVDF body with a conical tip  ideal for measurements in semi-solids such as meats and cheeses. The FC 202D is also provided with a free diffusion sleeve type reference junction which prevents the typical problems of clogging in viscous liquids such as milk or condiments. The electrolyte used in the FC 202D electrode is free from poisonous silver chloride which. in turn. effectively eliminates food contamination by the electrode.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 99161 is supplied with FC 202D pH\/temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 700642 electrode cleaning solution sachets (2). batteries. instructions and hard carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105.0°C\/23.0 to 221.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 20°C\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (up to 60°C). ±1.0°C (outside) \/ ±1.0°F (up to 140°F); ±2.0°F (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic one or two point calibration with two sets of memorized buffers (Standard 4.01. 7.01. 10.01 or NIST 4.01. 6.86. 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic. 0 to 60°C (32 to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFC 202D PVDF body. pre-amplified pH electrode with internal temperature sensor. DIN connector. 1 m (3.3’) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V (3) AAA \/ approximately 1200 hours of continuous use. auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e205g (7.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2026-06-25T15:26:24+12:00","created_at":"2015-09-04T15:13:27+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_pH \u0026 ORP Meters"],"price":87400,"price_min":87400,"price_max":87400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5764183173,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI99161","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 99161 FOODCARE pH Meter \/ Food and Dairy (HACCP Compliant)","public_title":null,"options":["Default Title"],"price":87400,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/foodcare-hand-ph-meter-fur-halbfeste-flussige-lebensmittel-1519_1-1_2015.jpeg?v=1443494808","\/\/acornsci.co.nz\/cdn\/shop\/products\/hi99161_400-1_2015.jpeg?v=1443494808"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/foodcare-hand-ph-meter-fur-halbfeste-flussige-lebensmittel-1519_1-1_2015.jpeg?v=1443494808","options":["Title"],"media":[{"alt":null,"id":25183027299,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/foodcare-hand-ph-meter-fur-halbfeste-flussige-lebensmittel-1519_1-1_2015.jpeg?v=1443494808"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/foodcare-hand-ph-meter-fur-halbfeste-flussige-lebensmittel-1519_1-1_2015.jpeg?v=1443494808","width":500},{"alt":null,"id":25183060067,"position":2,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi99161_400-1_2015.jpeg?v=1443494808"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi99161_400-1_2015.jpeg?v=1443494808","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eEasy to clean and keep clean\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eSpecialized dairy electrode\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eMulti-level LCD display\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eOn-screen tutorial messages for calibration and set-up\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic one or two point calibration\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBattery % displayed on startup.\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eCompact. heavy-duty. and waterproof\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eMonitoring pH in dairy processes is critical to ensure the quality of products.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe \u003cstrong\u003eHI 99161\u003c\/strong\u003e is a portable. pH and temperature meter is specifically designed for dairy applications.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eFC 202D pH electrode features a rugged. easy to clean. PVDF body with a conical tip  ideal for measurements in semi-solids such as meats and cheeses. The FC 202D is also provided with a free diffusion sleeve type reference junction which prevents the typical problems of clogging in viscous liquids such as milk or condiments. The electrolyte used in the FC 202D electrode is free from poisonous silver chloride which. in turn. effectively eliminates food contamination by the electrode.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 99161 is supplied with FC 202D pH\/temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 700642 electrode cleaning solution sachets (2). batteries. instructions and hard carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105.0°C\/23.0 to 221.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 20°C\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (up to 60°C). ±1.0°C (outside) \/ ±1.0°F (up to 140°F); ±2.0°F (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic one or two point calibration with two sets of memorized buffers (Standard 4.01. 7.01. 10.01 or NIST 4.01. 6.86. 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic. 0 to 60°C (32 to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eFC 202D PVDF body. pre-amplified pH electrode with internal temperature sensor. DIN connector. 1 m (3.3’) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V (3) AAA \/ approximately 1200 hours of continuous use. auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e205g (7.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

HANNA HI 99161 FOODCARE pH Meter / Food and Dairy (HACCP Compliant)

Product Description
  • Easy to clean and keep clean
  • Specialized dairy electrode
  • Multi-level LCD display
  • On-screen tutorial messages for calibration and set-up
  • Automatic Temperature Compensation
  • Automatic one or two point calibration
  • BEPS (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings
  • Battery % displayed on startup.
  • Compact. heavy-duty. and waterproof

 

Monitoring pH in dairy processes is critical to ensure the quality of products.

The HI 99161 is a portable. pH and temperature meter is specifically designed for dairy applications.

FC 202D pH electrode features a rugged. easy to clean. PVDF body with a conical tip  ideal for measurements in semi-solids such as meats and cheeses. The FC 202D is also provided with a free diffusion sleeve type reference junction which prevents the typical problems of clogging in viscous liquids such as milk or condiments. The electrolyte used in the FC 202D electrode is free from poisonous silver chloride which. in turn. effectively eliminates food contamination by the electrode.

 

 

Order Information:   HI 99161 is supplied with FC 202D pH/temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer solution sachet. HI 700642 electrode cleaning solution sachets (2). batteries. instructions and hard carrying case.

Specification :

Range pH -2.00 to 16.00 pH
  Temperature -5.0 to 105.0°C/23.0 to 221.0°F
Resolution pH 0.01 pH
  Temperature 0.1°C; 0.1°F
Accuracy @ 20°C pH ±0.02 pH
  Temperature ±0.5°C (up to 60°C). ±1.0°C (outside) / ±1.0°F (up to 140°F); ±2.0°F (outside)
pH Calibration   automatic one or two point calibration with two sets of memorized buffers (Standard 4.01. 7.01. 10.01 or NIST 4.01. 6.86. 9.18)
Temperature Compensation   Automatic. 0 to 60°C (32 to 140°F)
pH Electrode   FC 202D PVDF body. pre-amplified pH electrode with internal temperature sensor. DIN connector. 1 m (3.3’) cable
Battery Type / Life   1.5V (3) AAA / approximately 1200 hours of continuous use. auto-off after 8 minutes of non-use
Environment   0 to 50°C (32 to 122°F); RH max 100%
Dimensions   152 x 58 x 30 mm (6.0 x 2.3 x 1.2”)
Weight   205g (7.2 oz.)