Email info@acornsci.com for orders and inquiries.

{"id":5614026501,"title":"Vaisala HMT361 Transmitter and Probe Wall Mounting","handle":"hmt361-transmitter-and-probe-wall-mounting","description":"\u003cp\u003eThe HMT361 is the top-of-the-line wall-mounted intrinsically safe transmitter for hazardous areas. In addition to displaying humidity and temperature readings, the HMT361 calculates dew point, absolute humidity, wet bulb temperature, and mixing ratio. The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT360 series incorporates Vaisala’s 30 years of experience in industrial humidity measurement.\u003c\/p\u003e\n\u003cp\u003eThe transmitter has a large display for convenient monitoring of the reading and transmitter setting changes. For example scaling can easily be changed by the user.\u003c\/p\u003e\n\u003cp\u003eAnalog outputs are preset at the factory to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChannel 1: 4…20 mA = -40...+60°C (-40...+140°F) Td\u003c\/li\u003e\n\u003cli\u003eChannel 2: 4...20 mA = -40...+60°C (-40...+140°F) T\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSafe operation with the entire transmitter in hazardous areas: Div I and II (USA, Canada), Categories 1G\/Zone 0 and 1D\/Zone 20 with protection cover (EU).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIn order to achieve a safe installation\u003c\/b\u003e, each 4-20mA output requires an external intrinsically safe electrical surge barrier. Surge barriers should be located outside the hazardous area in a general purpose electronics enclosure. Each 4-20mA loop will require a separate barrier.\u003c\/p\u003e\n\u003cp\u003eThe package includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalibration certificate (ISO9001 compliant, traceable to NIST)\u003c\/li\u003e\n\u003cli\u003eNPT1\/2\" conduit fitting included to facilitate wiring\u003c\/li\u003e\n\u003cli\u003eUser's Guide in English\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDetailed information\u003c\/h3\u003e\n\u003ctable class=\"productdetails\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eMeasurement parameter(s)\u003c\/td\u003e\n\u003ctd\u003eRelative humidity\u003cbr\u003eAbsolute humidity\u003cbr\u003eTemperature\u003cbr\u003eDew point\u003cbr\u003eWet bulb\u003cbr\u003eMixing ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e0 ... 100 % RH\u003cbr\u003e-40 ... +60 °C (-40 ... +140 °F) T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003eAt temperature +20 °C (68 °F) ?± 1.0 % RH (0 ... 90 % RH) \u003cbr\u003e± 1.7 % RH (90 ... 100 % RH) \u003cbr\u003e± 0.2 °C (± 0.36 °F) T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003efor electronics -40 ...+ 60 °C (-40 ... +140 °F) \u003cbr\u003ewith display -20 ...+ 60 °C (-4 ... +140 °F) \u003cbr\u003estorage -40 ...+ 70 °C (-40 ... +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e12 ... 28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eAnalog outputs\u003c\/td\u003e\n\u003ctd\u003etwo-wire 4 ... 20 mA, one standard, one optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eDigital outputs\u003c\/td\u003e\n\u003ctd\u003eRS-232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eHousing classification\u003c\/td\u003e\n\u003ctd\u003eIP66 (NEMA 4X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2016-05-15T13:08:00+12:00","created_at":"2016-05-15T13:08:54+12:00","vendor":"Vaisala","type":"Temp \u0026 Humidity","tags":["brand_Vaisala","category_Temp \u0026 Humidity","Industry_Healthcare","Industry_Industrial Manufacturing","Manufacturer_Vaisala","Type_Devices"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":17760532101,"title":"HMT361-transmitter and probe wall mounting","option1":"HMT361-transmitter and probe wall mounting","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Vaisala HMT361 Transmitter and Probe Wall Mounting - HMT361-transmitter and probe wall mounting","public_title":"HMT361-transmitter and probe wall mounting","options":["HMT361-transmitter and probe wall mounting"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/Screen_Shot_2016-08-28_at_3.15.07_pm.png?v=1472354121"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/Screen_Shot_2016-08-28_at_3.15.07_pm.png?v=1472354121","options":["Title"],"media":[{"alt":null,"id":53815345251,"position":1,"preview_image":{"aspect_ratio":1.268,"height":250,"width":317,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/Screen_Shot_2016-08-28_at_3.15.07_pm.png?v=1472354121"},"aspect_ratio":1.268,"height":250,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/Screen_Shot_2016-08-28_at_3.15.07_pm.png?v=1472354121","width":317}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eThe HMT361 is the top-of-the-line wall-mounted intrinsically safe transmitter for hazardous areas. In addition to displaying humidity and temperature readings, the HMT361 calculates dew point, absolute humidity, wet bulb temperature, and mixing ratio. The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT360 series incorporates Vaisala’s 30 years of experience in industrial humidity measurement.\u003c\/p\u003e\n\u003cp\u003eThe transmitter has a large display for convenient monitoring of the reading and transmitter setting changes. For example scaling can easily be changed by the user.\u003c\/p\u003e\n\u003cp\u003eAnalog outputs are preset at the factory to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChannel 1: 4…20 mA = -40...+60°C (-40...+140°F) Td\u003c\/li\u003e\n\u003cli\u003eChannel 2: 4...20 mA = -40...+60°C (-40...+140°F) T\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSafe operation with the entire transmitter in hazardous areas: Div I and II (USA, Canada), Categories 1G\/Zone 0 and 1D\/Zone 20 with protection cover (EU).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIn order to achieve a safe installation\u003c\/b\u003e, each 4-20mA output requires an external intrinsically safe electrical surge barrier. Surge barriers should be located outside the hazardous area in a general purpose electronics enclosure. Each 4-20mA loop will require a separate barrier.\u003c\/p\u003e\n\u003cp\u003eThe package includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalibration certificate (ISO9001 compliant, traceable to NIST)\u003c\/li\u003e\n\u003cli\u003eNPT1\/2\" conduit fitting included to facilitate wiring\u003c\/li\u003e\n\u003cli\u003eUser's Guide in English\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eDetailed information\u003c\/h3\u003e\n\u003ctable class=\"productdetails\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eMeasurement parameter(s)\u003c\/td\u003e\n\u003ctd\u003eRelative humidity\u003cbr\u003eAbsolute humidity\u003cbr\u003eTemperature\u003cbr\u003eDew point\u003cbr\u003eWet bulb\u003cbr\u003eMixing ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eMeasurement range\u003c\/td\u003e\n\u003ctd\u003e0 ... 100 % RH\u003cbr\u003e-40 ... +60 °C (-40 ... +140 °F) T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eMeasurement accuracy\u003c\/td\u003e\n\u003ctd\u003eAt temperature +20 °C (68 °F) ?± 1.0 % RH (0 ... 90 % RH) \u003cbr\u003e± 1.7 % RH (90 ... 100 % RH) \u003cbr\u003e± 0.2 °C (± 0.36 °F) T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eOperating temperature\u003c\/td\u003e\n\u003ctd\u003efor electronics -40 ...+ 60 °C (-40 ... +140 °F) \u003cbr\u003ewith display -20 ...+ 60 °C (-4 ... +140 °F) \u003cbr\u003estorage -40 ...+ 70 °C (-40 ... +158 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eOperating voltage\u003c\/td\u003e\n\u003ctd\u003e12 ... 28 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eAnalog outputs\u003c\/td\u003e\n\u003ctd\u003etwo-wire 4 ... 20 mA, one standard, one optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eDigital outputs\u003c\/td\u003e\n\u003ctd\u003eRS-232C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"head\"\u003eHousing classification\u003c\/td\u003e\n\u003ctd\u003eIP66 (NEMA 4X)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

Vaisala HMT361 Transmitter and Probe Wall Mounting

Product Description

The HMT361 is the top-of-the-line wall-mounted intrinsically safe transmitter for hazardous areas. In addition to displaying humidity and temperature readings, the HMT361 calculates dew point, absolute humidity, wet bulb temperature, and mixing ratio. The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT360 series incorporates Vaisala’s 30 years of experience in industrial humidity measurement.

The transmitter has a large display for convenient monitoring of the reading and transmitter setting changes. For example scaling can easily be changed by the user.

Analog outputs are preset at the factory to:

  • Channel 1: 4…20 mA = -40...+60°C (-40...+140°F) Td
  • Channel 2: 4...20 mA = -40...+60°C (-40...+140°F) T

Safe operation with the entire transmitter in hazardous areas: Div I and II (USA, Canada), Categories 1G/Zone 0 and 1D/Zone 20 with protection cover (EU).

In order to achieve a safe installation, each 4-20mA output requires an external intrinsically safe electrical surge barrier. Surge barriers should be located outside the hazardous area in a general purpose electronics enclosure. Each 4-20mA loop will require a separate barrier.

The package includes:

  • Calibration certificate (ISO9001 compliant, traceable to NIST)
  • NPT1/2" conduit fitting included to facilitate wiring
  • User's Guide in English

Detailed information

Measurement parameter(s) Relative humidity
Absolute humidity
Temperature
Dew point
Wet bulb
Mixing ratio
Measurement range 0 ... 100 % RH
-40 ... +60 °C (-40 ... +140 °F) T
Measurement accuracy At temperature +20 °C (68 °F) ?± 1.0 % RH (0 ... 90 % RH) 
± 1.7 % RH (90 ... 100 % RH) 
± 0.2 °C (± 0.36 °F) T
Operating temperature for electronics -40 ...+ 60 °C (-40 ... +140 °F) 
with display -20 ...+ 60 °C (-4 ... +140 °F) 
storage -40 ...+ 70 °C (-40 ... +158 °F)
Operating voltage 12 ... 28 V
Analog outputs two-wire 4 ... 20 mA, one standard, one optional
Digital outputs RS-232C
Housing classification IP66 (NEMA 4X)

This product is available upon request. Contact us for more information.