{"id":2012190021,"title":"PCA 330-2 Online pH \/ ORP \/ Chlorine \/ °C - Analyzer \/ Controller","handle":"pca330-2","description":"\u003cp\u003eImplements the DPD colorimetric method to determine free or total chlorine concentration\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne point calibration of photometric cell\u003c\/li\u003e\n\u003cli\u003eUp to two point pH calibration and in-line pH electrode calibration support\u003c\/li\u003e\n\u003cli\u003eORP monitoring\u003c\/li\u003e\n\u003cli\u003eControl time cycles adjustable between 3 to 90 minutes\u003c\/li\u003e\n\u003cli\u003eProportional control of chlorine concentration\u003c\/li\u003e\n\u003cli\u003eProportional control of pH and ORP monitoring\u003c\/li\u003e\n\u003cli\u003eOut of range measurement and self-diagnostic system alarms\u003c\/li\u003e\n\u003cli\u003eParameter control through analog output or dedicated relays\u003c\/li\u003e\n\u003cli\u003eLogging space of up to of 3500 measurements and alarm status\u003c\/li\u003e\n\u003cli\u003eMulti-language support\u003c\/li\u003e\n\u003cli\u003eRS485 connectivity\u003c\/li\u003e\n\u003cli\u003epH and ORP probe sold seperarelty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eModels\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThe HANNA PCA 300 series models are chlorine and pH. ORP and temperature process analyzers which continuously monitor a sample stream and control the dosing to adjust the chlorine content and pH.\u003c\/p\u003e\n\u003cp\u003eFrom drinking and wastewater treatment to the pool and spa sanitation. the monitoring of chlorine. bromine or iodine levels has an important bearing on public health as well as ROI and efficiency for heating system and industrial applications.\u003c\/p\u003e\n\u003cp\u003eThe PCA 3X0 series monitors the free chlorine or total chlorine in the 0 to 5.0 mg\/L range;\u003c\/p\u003e\n\u003cp\u003eIn the DPD Colorimetric method. N. N-Diethyl-p-phenylene-Diamine indicator and a buffer are mixed with the sample. Free available chlorine oxidizes the DPD indicator reagent at a pH between 6.3 and 6.6 to form a magenta colored compound. The intensity of the resulting color is proportional to the concentration of chlorine in the sample. The purpose of the buffer solution is to maintain the proper pH.\u003c\/p\u003e\n\u003cp\u003eIn total chlorine measurement (free available chlorine plus combined chloramines). potassium iodide is added. A pH of 5.1 is required for this reaction. Thus total chlorine measurements require a different buffer solution containing potassium iodide. Once the chemical reaction is completed. the optical signal at 555 nm is compared to the signal measured through the sample before the reagents were added. From these measurements chlorine concentration is calculated and shown on the display.\u003c\/p\u003e\n\u003cp\u003eIndicator and buffer reagent bottles are placed directly into the instrument case. With a sampling period of 5 minutes. reagents need only to be replenished about once a month.\u003cbr\u003e Since chlorine. bromine and iodine effectiveness is closely tied with pH levels. HANNA has designed our new analyzers PCA 32X and PCA 33X with pH control and temperature and pH control. ORP monitoring and temperature respectively.\u003c\/p\u003e\n\u003cp\u003ePCA 32X and PCA 33X use the HI 1005 pH probe to continuously measure the pH of the sample stream in the range of 0 to 14 pH. The sample temperature is measured in the 5 to 75°C range. pH and temperature are displayed on the front panel. and the pH value is temperature compensated.\u003c\/p\u003e\n\u003cp\u003ePCA 33X uses the HI 2008 platinum ORP electrode to continuously measure the sample ORP value. The pH\/temperature combined sensor and the ORP sensor are placed inside the case. directly in the sample stream.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eMeasurement and Control Cycle\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThe PCA has a control time cycle that can be set by the user according with the dimensions of the controlled system. The control process. dosing commands and alarms can be performed according to this time cycle. The range of cycle timing is from 3 to 90 minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eChlorine Control\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eFour chlorine level set points can be adjusted by the operator: a proportional dosing set point. two alarm set points and a minimum level for dosing. The proportional dosing factor (1\/Δ) is user selectable with a delta between 0.1 and 2 pH. Chlorine\/ bromine\/iodine dosing system controls a SPST relay. Each alarm can be enabled or disabled.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003epH Control\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThree pH level set points can be adjusted by the operator: a control set point and two alarm set points. The pH control mode is user selectable; on\/off or proportional dosing. The proportional dosing factor (1\/Δ) is user selectable with a delta between 0.1 and 2 pH. The on\/off dosing hysteresis is user selectable between 0.05 and 2.00 pH. The pH dosing system controls a SPST relay.\u003c\/p\u003e\n\u003cp\u003eEach pH. ORP and temperature alarm can be enabled or disabled. and two alarm levels can be set by the user also for temperature and ORP. Alarm condition controls a SPDT relay. The system error feature activates a relay to signal the need for operator intervention. System error condition controls a SPST relay.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eAnalog Output\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eTwo current outputs of 4-20 mA or 0-20 mA are available to drive external devices such as chart recorders. The analyzer can drive two dosing pumps through the 4-20 mA outputs for chloride and acid\/alkali dosing. The analog output is fully programmable and can be proportional with chlorine concentration. pH. ORP or temperature value. The limits of the analog output is selectable for each parameter.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eLogging\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThe analyzers can store up to 3500 readings (at least 7 days at 3 minutes sampling interval). that can be available for consulting or downloading. Logged records contain the time stamp. full information about the parameter values and the alarm status at the time.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eAlarm and Warning System\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThrough the system. users have the ability to enable or disable the low and high level of alarms for all parameters. The system also offers overdosing protection that generates an alarm if something within the system is not working properly. The system will stop processes until the error is corrected by the user. Time is displayed on the main panel and time related reminders are available for “old calibration”. “reagent expired”. and “SIM expired”. All these warnings are generated based on user settings.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eMounting\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThese controllers are offered in an easy to access. wall mounted casing that offers outstanding chemical. mechanical and temperature resistance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e Each PCA 300 series model is supplied with reagent bottles (2). reagent caps (2). 1 DPD compound powder. tubing and instructions. (Probes are sold Separately) \u003cbr\u003e \u003cbr\u003e PCA 330-2 Free \u0026amp; total chlorine analyzer\/control. pH control. ORP monitoring. temperature (230V)\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manPCA_310_320_330.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.00 to 5.00 mg\/L (ppm)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.00 to 14.00 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eORP\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0 to 2000 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e5.0 to 75.0 °C (41 to 167 °F)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.01 mg\/L (ppm)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.01 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eORP\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 °C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±8% or ±0.05 mg\/L whichever is greater\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.05 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eORP\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±1 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.5°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin. Detectable\u003cbr\u003eLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.05 mg\/L (ppm)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eone point\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eone or two point or in line calibration\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eadjustable from 3 to 90 minutes\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eadjustable from 3 to 120 seconds\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDosage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eproportional\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eON\/OFF or proportional. relay or 4-20mA output\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelta\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eselectable from 0.1 to 5 mg\/L (ppm)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eselectable from 0.1 to 2 pH (hysteresis adjustable from 0.05 to 2 pH)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e4-20mA. 0-20mA\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eRS485 port. galvanically isolated\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1200. 2400. 4800. 9600 bps\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eup to 3500 data points\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSPDT contact with 5A. 230V resistive load\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDosing Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSPDT contact with 5A. 230V resistive load\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSPDT contact with 5A. 230V resistive load\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.07 to 4 bar with no external pressure regulator (for pressure exceeding four bar an external pressure regulator is required)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e100 to 300 mL\/min\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e5 to 40°C (41 to 104°F)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Inlet\/\u003cbr\u003eOutlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e12mm (1\/2\") male NPT fitting\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e10mm (3\/8\") barb\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e115 VAC ±10% or 230 VAC ±10%; 50\/60 Hz; 20 VA\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eNEMA-4X standard. molded fiberglass polyester with transparent Lexan window\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\/Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e318 x 267 x 159 mm (12.5 x 10.5 x 6.25’’) \/ 5 kg (11 lb.) without reagents\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2026-06-25T15:26:14+12:00","created_at":"2015-09-04T15:21:43+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_pH \u0026 ORP Meters"],"price":323000,"price_min":323000,"price_max":323000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5764429381,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"PCA330-2","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"PCA 330-2 Online pH \/ ORP \/ Chlorine \/ °C - Analyzer \/ Controller","public_title":null,"options":["Default Title"],"price":323000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/analyseurregulateur-de-chlore-en-continu-mesure-du-ph-et-c-2350_1-1_2015.jpeg?v=1443495493","\/\/acornsci.co.nz\/cdn\/shop\/products\/41wo2kb3dml-_sl500_aa300_-1_2015.jpeg?v=1443495493"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/analyseurregulateur-de-chlore-en-continu-mesure-du-ph-et-c-2350_1-1_2015.jpeg?v=1443495493","options":["Title"],"media":[{"alt":null,"id":25185452131,"position":1,"preview_image":{"aspect_ratio":0.879,"height":799,"width":702,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/analyseurregulateur-de-chlore-en-continu-mesure-du-ph-et-c-2350_1-1_2015.jpeg?v=1443495493"},"aspect_ratio":0.879,"height":799,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/analyseurregulateur-de-chlore-en-continu-mesure-du-ph-et-c-2350_1-1_2015.jpeg?v=1443495493","width":702},{"alt":null,"id":25185484899,"position":2,"preview_image":{"aspect_ratio":1.0,"height":300,"width":300,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/41wo2kb3dml-_sl500_aa300_-1_2015.jpeg?v=1443495493"},"aspect_ratio":1.0,"height":300,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/41wo2kb3dml-_sl500_aa300_-1_2015.jpeg?v=1443495493","width":300}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eImplements the DPD colorimetric method to determine free or total chlorine concentration\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOne point calibration of photometric cell\u003c\/li\u003e\n\u003cli\u003eUp to two point pH calibration and in-line pH electrode calibration support\u003c\/li\u003e\n\u003cli\u003eORP monitoring\u003c\/li\u003e\n\u003cli\u003eControl time cycles adjustable between 3 to 90 minutes\u003c\/li\u003e\n\u003cli\u003eProportional control of chlorine concentration\u003c\/li\u003e\n\u003cli\u003eProportional control of pH and ORP monitoring\u003c\/li\u003e\n\u003cli\u003eOut of range measurement and self-diagnostic system alarms\u003c\/li\u003e\n\u003cli\u003eParameter control through analog output or dedicated relays\u003c\/li\u003e\n\u003cli\u003eLogging space of up to of 3500 measurements and alarm status\u003c\/li\u003e\n\u003cli\u003eMulti-language support\u003c\/li\u003e\n\u003cli\u003eRS485 connectivity\u003c\/li\u003e\n\u003cli\u003epH and ORP probe sold seperarelty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eModels\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThe HANNA PCA 300 series models are chlorine and pH. ORP and temperature process analyzers which continuously monitor a sample stream and control the dosing to adjust the chlorine content and pH.\u003c\/p\u003e\n\u003cp\u003eFrom drinking and wastewater treatment to the pool and spa sanitation. the monitoring of chlorine. bromine or iodine levels has an important bearing on public health as well as ROI and efficiency for heating system and industrial applications.\u003c\/p\u003e\n\u003cp\u003eThe PCA 3X0 series monitors the free chlorine or total chlorine in the 0 to 5.0 mg\/L range;\u003c\/p\u003e\n\u003cp\u003eIn the DPD Colorimetric method. N. N-Diethyl-p-phenylene-Diamine indicator and a buffer are mixed with the sample. Free available chlorine oxidizes the DPD indicator reagent at a pH between 6.3 and 6.6 to form a magenta colored compound. The intensity of the resulting color is proportional to the concentration of chlorine in the sample. The purpose of the buffer solution is to maintain the proper pH.\u003c\/p\u003e\n\u003cp\u003eIn total chlorine measurement (free available chlorine plus combined chloramines). potassium iodide is added. A pH of 5.1 is required for this reaction. Thus total chlorine measurements require a different buffer solution containing potassium iodide. Once the chemical reaction is completed. the optical signal at 555 nm is compared to the signal measured through the sample before the reagents were added. From these measurements chlorine concentration is calculated and shown on the display.\u003c\/p\u003e\n\u003cp\u003eIndicator and buffer reagent bottles are placed directly into the instrument case. With a sampling period of 5 minutes. reagents need only to be replenished about once a month.\u003cbr\u003e Since chlorine. bromine and iodine effectiveness is closely tied with pH levels. HANNA has designed our new analyzers PCA 32X and PCA 33X with pH control and temperature and pH control. ORP monitoring and temperature respectively.\u003c\/p\u003e\n\u003cp\u003ePCA 32X and PCA 33X use the HI 1005 pH probe to continuously measure the pH of the sample stream in the range of 0 to 14 pH. The sample temperature is measured in the 5 to 75°C range. pH and temperature are displayed on the front panel. and the pH value is temperature compensated.\u003c\/p\u003e\n\u003cp\u003ePCA 33X uses the HI 2008 platinum ORP electrode to continuously measure the sample ORP value. The pH\/temperature combined sensor and the ORP sensor are placed inside the case. directly in the sample stream.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eMeasurement and Control Cycle\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThe PCA has a control time cycle that can be set by the user according with the dimensions of the controlled system. The control process. dosing commands and alarms can be performed according to this time cycle. The range of cycle timing is from 3 to 90 minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eChlorine Control\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eFour chlorine level set points can be adjusted by the operator: a proportional dosing set point. two alarm set points and a minimum level for dosing. The proportional dosing factor (1\/Δ) is user selectable with a delta between 0.1 and 2 pH. Chlorine\/ bromine\/iodine dosing system controls a SPST relay. Each alarm can be enabled or disabled.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003epH Control\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThree pH level set points can be adjusted by the operator: a control set point and two alarm set points. The pH control mode is user selectable; on\/off or proportional dosing. The proportional dosing factor (1\/Δ) is user selectable with a delta between 0.1 and 2 pH. The on\/off dosing hysteresis is user selectable between 0.05 and 2.00 pH. The pH dosing system controls a SPST relay.\u003c\/p\u003e\n\u003cp\u003eEach pH. ORP and temperature alarm can be enabled or disabled. and two alarm levels can be set by the user also for temperature and ORP. Alarm condition controls a SPDT relay. The system error feature activates a relay to signal the need for operator intervention. System error condition controls a SPST relay.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eAnalog Output\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eTwo current outputs of 4-20 mA or 0-20 mA are available to drive external devices such as chart recorders. The analyzer can drive two dosing pumps through the 4-20 mA outputs for chloride and acid\/alkali dosing. The analog output is fully programmable and can be proportional with chlorine concentration. pH. ORP or temperature value. The limits of the analog output is selectable for each parameter.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eLogging\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThe analyzers can store up to 3500 readings (at least 7 days at 3 minutes sampling interval). that can be available for consulting or downloading. Logged records contain the time stamp. full information about the parameter values and the alarm status at the time.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eAlarm and Warning System\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThrough the system. users have the ability to enable or disable the low and high level of alarms for all parameters. The system also offers overdosing protection that generates an alarm if something within the system is not working properly. The system will stop processes until the error is corrected by the user. Time is displayed on the main panel and time related reminders are available for “old calibration”. “reagent expired”. and “SIM expired”. All these warnings are generated based on user settings.\u003c\/p\u003e\n\u003cp\u003e\u003cbig\u003e\u003cspan style=\"font-size: x-large;\"\u003eMounting\u003c\/span\u003e\u003c\/big\u003e\u003c\/p\u003e\n\u003cp\u003eThese controllers are offered in an easy to access. wall mounted casing that offers outstanding chemical. mechanical and temperature resistance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003e Each PCA 300 series model is supplied with reagent bottles (2). reagent caps (2). 1 DPD compound powder. tubing and instructions. (Probes are sold Separately) \u003cbr\u003e \u003cbr\u003e PCA 330-2 Free \u0026amp; total chlorine analyzer\/control. pH control. ORP monitoring. temperature (230V)\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manPCA_310_320_330.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.00 to 5.00 mg\/L (ppm)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.00 to 14.00 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eORP\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0 to 2000 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e5.0 to 75.0 °C (41 to 167 °F)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.01 mg\/L (ppm)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.01 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eORP\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.1 °C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±8% or ±0.05 mg\/L whichever is greater\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.05 pH\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eORP\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±1 mV\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eTemperature\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e±0.5°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMin. Detectable\u003cbr\u003eLevel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.05 mg\/L (ppm)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohm\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eone point\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eone or two point or in line calibration\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eadjustable from 3 to 90 minutes\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eadjustable from 3 to 120 seconds\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDosage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eproportional\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eON\/OFF or proportional. relay or 4-20mA output\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDelta\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eFree \u0026amp; Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eselectable from 0.1 to 5 mg\/L (ppm)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epH\u003c\/span\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eselectable from 0.1 to 2 pH (hysteresis adjustable from 0.05 to 2 pH)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRecorder Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e4-20mA. 0-20mA\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eRS485 port. galvanically isolated\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e1200. 2400. 4800. 9600 bps\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eup to 3500 data points\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSPDT contact with 5A. 230V resistive load\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDosing Relay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSPDT contact with 5A. 230V resistive load\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSystem Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eSPDT contact with 5A. 230V resistive load\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e0.07 to 4 bar with no external pressure regulator (for pressure exceeding four bar an external pressure regulator is required)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Flow\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e100 to 300 mL\/min\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e5 to 40°C (41 to 104°F)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSample Inlet\/\u003cbr\u003eOutlet Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e12mm (1\/2\") male NPT fitting\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDrain Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e10mm (3\/8\") barb\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e115 VAC ±10% or 230 VAC ±10%; 50\/60 Hz; 20 VA\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eNEMA-4X standard. molded fiberglass polyester with transparent Lexan window\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\/Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e318 x 267 x 159 mm (12.5 x 10.5 x 6.25’’) \/ 5 kg (11 lb.) without reagents\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}
PCA 330-2 Online pH / ORP / Chlorine / °C - Analyzer / Controller
Related Products
Biobase PH-210 Benchtop pH meter
$1,229.00 $1,695.00
Carbolite Heating element 200mm long
$799.00 $850.00
Carbolite Thermocouple for AAF11/3
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00
Carbolite Thermocouple for AAF11/7
$299.00 $464.00














