Email info@acornsci.com for orders and inquiries.

{"id":8096160088360,"title":"AIRCLEAN SYSTEMS AC600 Series Endoscopy Workstation Ductless","handle":"airclean-systems-ac600-series-endoscopy-workstation-ductless","description":"\u003cdiv class=\"o_g parameterList\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_g parameterList\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\"\u003e\n\u003ch2 data-v-34176663=\"\"\u003eProduct Parameters\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe AC600 Series endoscopy workstation is an economical and space-saving solution, providing technician protection from high-level disinfectant vapors. The AirSafe™ automatic safety controller maintains the user-set face velocity during endoscope reprocessing, while additionally monitoring airflow and filter conditions. Multiple sizes and a small footprint allow this product to fit on virtually any countertop.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-2 text-white h5 p-2\"\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirSafe® automatic safety controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegral base with deep spill lip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNo ductwork required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNo installation required - plugs directly into a standard 110V or 220V electrical outlet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExtremely quiet operation \u0026lt; 49dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLab event timer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGas phase bonded carbon filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient text-white h5 p-2\"\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter safety lockout to ensure correct filter replacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeets OSHA and JCAHO regulatory requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtects operator from Glutaraldehyde, O.P.A., Cidex®, Hydrogen Peroxide or Peracetic Acid fumes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic gas detection for real-time gas phase filter monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeets AAMI\/ANSI ST 58 standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrushless, sparkless blower is post-filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDeep base effectively contains accidental spills\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLow airflow alarm warns the user both visually and audibly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-3 text-white h5 p-2\"\u003e\u003cspan\u003eOptions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSturdy cart\/trolley with locking casters for mobility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFluorescent lighting optional on all 32\" width workstations; standard on 48\" workstations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGlutAway™ waste pump for transferring disinfectant and rinse water to waste\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSoaking pans with lid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHard surface disinfectant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"sliderTable mt10 mb10 sliderTable-index0\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003ch4\u003eHow it Works\u003c\/h4\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cul class=\"list-group list-group-flush\"\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eA\u003c\/span\u003e\n\u003cp\u003eRoom air flows away from the operator and enters the enclosure in a horizontal pattern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eB\u003c\/span\u003e\n\u003cp\u003eRoom air mixes with both lighter and heavier gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eC\u003c\/span\u003e\n\u003cp\u003eMixed air is drawn into the AirZone™ baffling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eD\u003c\/span\u003e\n\u003cp\u003eContaminated air is directed through the filtration bed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eE\u003c\/span\u003e\n\u003cp\u003eClean air is recirculated into the room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003cimg alt=\"Air Flow Diagram\" src=\"https:\/\/www.aircleansystems.com\/img\/diagram\/airflow-diagram-02.svg\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"table-responsive table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth rowspan=\"2\"\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eExternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC632C\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003ctd\u003e610mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC648C\u003c\/td\u003e\n\u003ctd\u003e1219mm\u003c\/td\u003e\n\u003ctd\u003e610mm\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eInternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC632C\u003c\/td\u003e\n\u003ctd\u003e787mm\u003c\/td\u003e\n\u003ctd\u003e584mm\u003c\/td\u003e\n\u003ctd\u003e559mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC648C\u003c\/td\u003e\n\u003ctd\u003e1194mm\u003c\/td\u003e\n\u003ctd\u003e584mm\u003c\/td\u003e\n\u003ctd\u003e559mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2023-02-02T14:50:08+13:00","created_at":"2023-02-02T14:47:27+13:00","vendor":"AirClean Systems","type":"Fume Hoods","tags":["Category_Fume Hoods","Features_Ductless","Manufacturer_Airclean Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":44987645034792,"title":"Fume Hoods \/ Ductless","option1":"Fume Hoods","option2":"Ductless","option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"AIRCLEAN SYSTEMS AC600 Series Endoscopy Workstation Ductless - Fume Hoods \/ Ductless","public_title":"Fume Hoods \/ Ductless","options":["Fume Hoods","Ductless"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/ac600-series-ductless-endoscopy-workstation-1.webp?v=1675302468","\/\/acornsci.co.nz\/cdn\/shop\/products\/ac600-series-ductless-endoscopy-workstation-2.webp?v=1675302474"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/ac600-series-ductless-endoscopy-workstation-1.webp?v=1675302468","options":["Category","Features"],"media":[{"alt":null,"id":33102280950056,"position":1,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/ac600-series-ductless-endoscopy-workstation-1.webp?v=1675302468"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/ac600-series-ductless-endoscopy-workstation-1.webp?v=1675302468","width":700},{"alt":null,"id":33102281048360,"position":2,"preview_image":{"aspect_ratio":1.0,"height":700,"width":700,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/ac600-series-ductless-endoscopy-workstation-2.webp?v=1675302474"},"aspect_ratio":1.0,"height":700,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/ac600-series-ductless-endoscopy-workstation-2.webp?v=1675302474","width":700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv class=\"o_g parameterList\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"o_g parameterList\"\u003e\n\u003cdiv class=\"o_u o_df_1-3 o_xs_2-2\"\u003e\n\u003ch2 data-v-34176663=\"\"\u003eProduct Parameters\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe AC600 Series endoscopy workstation is an economical and space-saving solution, providing technician protection from high-level disinfectant vapors. The AirSafe™ automatic safety controller maintains the user-set face velocity during endoscope reprocessing, while additionally monitoring airflow and filter conditions. Multiple sizes and a small footprint allow this product to fit on virtually any countertop.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-2 text-white h5 p-2\"\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAirSafe® automatic safety controller\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIntegral base with deep spill lip\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNo ductwork required\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eNo installation required - plugs directly into a standard 110V or 220V electrical outlet\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eExtremely quiet operation \u0026lt; 49dBA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLab event timer\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGas phase bonded carbon filtration\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient text-white h5 p-2\"\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter safety lockout to ensure correct filter replacement\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeets OSHA and JCAHO regulatory requirements\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtects operator from Glutaraldehyde, O.P.A., Cidex®, Hydrogen Peroxide or Peracetic Acid fumes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eElectronic gas detection for real-time gas phase filter monitoring\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMeets AAMI\/ANSI ST 58 standard\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrushless, sparkless blower is post-filter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDeep base effectively contains accidental spills\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFilter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eLow airflow alarm warns the user both visually and audibly\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003cbr\u003e\u003c\/p\u003e\n\u003ctable class=\"table table-hover table-sm\"\u003e\n\u003cthead class=\"thead-light\"\u003e\n\u003ctr\u003e\n\u003ctd class=\"table-secondary bg-gradient-3 text-white h5 p-2\"\u003e\u003cspan\u003eOptions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSturdy cart\/trolley with locking casters for mobility\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eFluorescent lighting optional on all 32\" width workstations; standard on 48\" workstations\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGlutAway™ waste pump for transferring disinfectant and rinse water to waste\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSoaking pans with lid\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eHard surface disinfectant\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"sliderTable mt10 mb10 sliderTable-index0\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003ch4\u003eHow it Works\u003c\/h4\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-6\"\u003e\n\u003cul class=\"list-group list-group-flush\"\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eA\u003c\/span\u003e\n\u003cp\u003eRoom air flows away from the operator and enters the enclosure in a horizontal pattern.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eB\u003c\/span\u003e\n\u003cp\u003eRoom air mixes with both lighter and heavier gases.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eC\u003c\/span\u003e\n\u003cp\u003eMixed air is drawn into the AirZone™ baffling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eD\u003c\/span\u003e\n\u003cp\u003eContaminated air is directed through the filtration bed.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"list-group-item pt-4\"\u003e\n\u003cspan\u003eE\u003c\/span\u003e\n\u003cp\u003eClean air is recirculated into the room.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003cimg alt=\"Air Flow Diagram\" src=\"https:\/\/www.aircleansystems.com\/img\/diagram\/airflow-diagram-02.svg\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"col-md-6 how-it-works\"\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"table-responsive table-bordered table-hover\"\u003e\n\u003ctbody\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth rowspan=\"2\"\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eExternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWidth\u003c\/td\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC632C\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003ctd\u003e610mm\u003c\/td\u003e\n\u003ctd\u003e762mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC648C\u003c\/td\u003e\n\u003ctd\u003e1219mm\u003c\/td\u003e\n\u003ctd\u003e610mm\u003c\/td\u003e\n\u003ctd\u003e813mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"table-secondary\"\u003e\n\u003cth\u003eProduct #\u003c\/th\u003e\n\u003cth colspan=\"3\"\u003eInternal\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC632C\u003c\/td\u003e\n\u003ctd\u003e787mm\u003c\/td\u003e\n\u003ctd\u003e584mm\u003c\/td\u003e\n\u003ctd\u003e559mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC648C\u003c\/td\u003e\n\u003ctd\u003e1194mm\u003c\/td\u003e\n\u003ctd\u003e584mm\u003c\/td\u003e\n\u003ctd\u003e559mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

AIRCLEAN SYSTEMS AC600 Series Endoscopy Workstation Ductless

Product Description

Product Parameters

The AC600 Series endoscopy workstation is an economical and space-saving solution, providing technician protection from high-level disinfectant vapors. The AirSafe™ automatic safety controller maintains the user-set face velocity during endoscope reprocessing, while additionally monitoring airflow and filter conditions. Multiple sizes and a small footprint allow this product to fit on virtually any countertop.

Features
AirSafe® automatic safety controller
Integral base with deep spill lip
No ductwork required
No installation required - plugs directly into a standard 110V or 220V electrical outlet
Extremely quiet operation < 49dBA
Lab event timer
Gas phase bonded carbon filtration

Benefits
Filter safety lockout to ensure correct filter replacement
Meets OSHA and JCAHO regulatory requirements
Protects operator from Glutaraldehyde, O.P.A., Cidex®, Hydrogen Peroxide or Peracetic Acid fumes
Electronic gas detection for real-time gas phase filter monitoring
Tested to UL 61010-1,CSA C22.2 No. 61010-1, and EN 61326-1
Meets AAMI/ANSI ST 58 standard
Brushless, sparkless blower is post-filter
Deep base effectively contains accidental spills
Filter and electronics are located above the workspace, eliminating the chance of a chemical spill entering these sensitive areas
Low airflow alarm warns the user both visually and audibly

 

Options
Sturdy cart/trolley with locking casters for mobility
Fluorescent lighting optional on all 32" width workstations; standard on 48" workstations
GlutAway™ waste pump for transferring disinfectant and rinse water to waste
Soaking pans with lid
Hard surface disinfectant

How it Works

  • A

    Room air flows away from the operator and enters the enclosure in a horizontal pattern.

  • B

    Room air mixes with both lighter and heavier gases.

  • C

    Mixed air is drawn into the AirZone™ baffling.

  • D

    Contaminated air is directed through the filtration bed.

  • E

    Clean air is recirculated into the room.

Air Flow Diagram

Product # External
Width Depth Height
AC632C 813mm 610mm 762mm
AC648C 1219mm 610mm 813mm
Product # Internal
AC632C 787mm 584mm 559mm
AC648C 1194mm 584mm 559mm

This product is available upon request. Contact us for more information.