{"id":6588971319395,"title":"IKA AOD1.2","handle":"ika-aod1-2","description":"External ignition unit for decomposition vessel AOD 1.1 with 5 m ignition cable. Either it is required to use the AOD 1.3 Protection device, or if another suitable protection device is already in place, the AOD 1.13 Remote ignition head (additional cable length) of 1 m. \u003cbr\u003e","published_at":"2021-06-09T13:12:30+12:00","created_at":"2021-06-09T13:12:29+12:00","vendor":"IKA","type":"Decomposition Systems","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Decomposition Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39417952862307,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA AOD1.2","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1.2_1.jpg?v=1623201151"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1.2_1.jpg?v=1623201151","options":["Title"],"media":[{"alt":null,"id":20603962753123,"position":1,"preview_image":{"aspect_ratio":1.124,"height":890,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1.2_1.jpg?v=1623201151"},"aspect_ratio":1.124,"height":890,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1.2_1.jpg?v=1623201151","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"External ignition unit for decomposition vessel AOD 1.1 with 5 m ignition cable. Either it is required to use the AOD 1.3 Protection device, or if another suitable protection device is already in place, the AOD 1.13 Remote ignition head (additional cable length) of 1 m. \u003cbr\u003e"}
- Home
- Decomposition Systems
- IKA AOD1.2
IKA AOD1.2
Related Products
{"id":6588971909219,"title":"IKA C 6030 Venting station","handle":"ika-c-6030-venting-station","description":"","published_at":"2021-06-09T13:15:14+12:00","created_at":"2021-06-09T13:15:13+12:00","vendor":"IKA","type":"Decomposition Systems","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Decomposition Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39417954566243,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA C 6030 Venting station","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/C6030Ventingstation_1.jpg?v=1623201314"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C6030Ventingstation_1.jpg?v=1623201314","options":["Title"],"media":[{"alt":null,"id":20603970846819,"position":1,"preview_image":{"aspect_ratio":1.208,"height":828,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C6030Ventingstation_1.jpg?v=1623201314"},"aspect_ratio":1.208,"height":828,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C6030Ventingstation_1.jpg?v=1623201314","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":""}

{"id":6588971647075,"title":"IKA C 1.30 Venting station","handle":"ika-c-1-30-venting-station","description":"","published_at":"2021-06-09T13:14:07+12:00","created_at":"2021-06-09T13:14:05+12:00","vendor":"IKA","type":"Decomposition Systems","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Decomposition Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39417953517667,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA C 1.30 Venting station","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/C1.30Ventingstation_1.jpg?v=1623201247"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C1.30Ventingstation_1.jpg?v=1623201247","options":["Title"],"media":[{"alt":null,"id":20603968782435,"position":1,"preview_image":{"aspect_ratio":1.163,"height":860,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C1.30Ventingstation_1.jpg?v=1623201247"},"aspect_ratio":1.163,"height":860,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C1.30Ventingstation_1.jpg?v=1623201247","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":""}

{"id":6588970106979,"title":"IKA AOD 1.3 Protection device","handle":"ika-aod-1-3-protection-device","description":"","published_at":"2021-06-09T13:06:55+12:00","created_at":"2021-06-09T13:06:54+12:00","vendor":"IKA","type":"Decomposition Systems","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Decomposition Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39417950306403,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA AOD 1.3 Protection device","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1.3Protectiondevice_1.jpg?v=1623200815"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1.3Protectiondevice_1.jpg?v=1623200815","options":["Title"],"media":[{"alt":null,"id":20603942830179,"position":1,"preview_image":{"aspect_ratio":0.922,"height":1000,"width":922,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1.3Protectiondevice_1.jpg?v=1623200815"},"aspect_ratio":0.922,"height":1000,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1.3Protectiondevice_1.jpg?v=1623200815","width":922}],"requires_selling_plan":false,"selling_plan_groups":[],"content":""}

{"id":6588969680995,"title":"IKA C 48 Oxygen station","handle":"ika-c-48-oxygen-station","description":"for a precise and reproducible oxygen filling of the decomposition vessels \u003cbr data-mce-fragment=\"1\"\u003e C 7010 and C 7012","published_at":"2021-06-09T13:05:37+12:00","created_at":"2021-06-09T13:05:36+12:00","vendor":"IKA","type":"Decomposition Systems","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Decomposition Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39417949388899,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA C 48 Oxygen station","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/C48Oxygenstation_1.jpg?v=1623200737"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C48Oxygenstation_1.jpg?v=1623200737","options":["Title"],"media":[{"alt":null,"id":20603938504803,"position":1,"preview_image":{"aspect_ratio":0.597,"height":1000,"width":597,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C48Oxygenstation_1.jpg?v=1623200737"},"aspect_ratio":0.597,"height":1000,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C48Oxygenstation_1.jpg?v=1623200737","width":597}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"for a precise and reproducible oxygen filling of the decomposition vessels \u003cbr data-mce-fragment=\"1\"\u003e C 7010 and C 7012"}

IKA C 48 Oxygen station
for a precise and reproducible oxygen filling of the decomposition vessels C 7010 and C 7012
More Info
{"id":6588967288931,"title":"IKA C 5030 Venting station","handle":"ika-c-5030-venting-station","description":"to control the degassing process of the combustion gases after the decomposition \u003cbr data-mce-fragment=\"1\"\u003eSuitable for the C 5010 and C 5012 decomposition vessels","published_at":"2021-06-09T12:56:27+12:00","created_at":"2021-06-09T12:56:25+12:00","vendor":"IKA","type":"Decomposition Systems","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Decomposition Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39417938608227,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA C 5030 Venting station","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/C5030Ventingstation_1.jpg?v=1623200187"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C5030Ventingstation_1.jpg?v=1623200187","options":["Title"],"media":[{"alt":null,"id":20603918090339,"position":1,"preview_image":{"aspect_ratio":1.003,"height":997,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C5030Ventingstation_1.jpg?v=1623200187"},"aspect_ratio":1.003,"height":997,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C5030Ventingstation_1.jpg?v=1623200187","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"to control the degassing process of the combustion gases after the decomposition \u003cbr data-mce-fragment=\"1\"\u003eSuitable for the C 5010 and C 5012 decomposition vessels"}

IKA C 5030 Venting station
to control the degassing process of the combustion gases after the decomposition Suitable for the C 5010 and C 5012 decomposition vessels
More Info
{"id":6588967059555,"title":"IKA C 7030 Venting station","handle":"ika-c-7030-venting-station","description":"To control the degassing process of the combustion gases after the decomposition \u003cbr data-mce-fragment=\"1\"\u003eSuitable for the C 7010 and C 7012 decomposition vessels","published_at":"2021-06-09T12:55:31+12:00","created_at":"2021-06-09T12:55:30+12:00","vendor":"IKA","type":"Decomposition Systems","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Decomposition Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39417937854563,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA C 7030 Venting station","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/C7030Ventingstation_1.jpg?v=1623200132"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C7030Ventingstation_1.jpg?v=1623200132","options":["Title"],"media":[{"alt":null,"id":20603915599971,"position":1,"preview_image":{"aspect_ratio":0.917,"height":1000,"width":917,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C7030Ventingstation_1.jpg?v=1623200132"},"aspect_ratio":0.917,"height":1000,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C7030Ventingstation_1.jpg?v=1623200132","width":917}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"To control the degassing process of the combustion gases after the decomposition \u003cbr data-mce-fragment=\"1\"\u003eSuitable for the C 7010 and C 7012 decomposition vessels"}

IKA C 7030 Venting station
To control the degassing process of the combustion gases after the decomposition Suitable for the C 7010 and C 7012 decomposition vessels
More Info
{"id":6588966830179,"title":"IKA AOD 1 Decomposition system","handle":"aod-1-decomposition-system","description":"The AOD 1 is used for oxidative decomposition of solid and liquid organic and partially inorganic samples under pressure in a closed system. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe system consists of: \u003cbr data-mce-fragment=\"1\"\u003eAOD 1.1 Decomposition vessel, C 48 Oxygen station, AOD 1.2 External ignition unit, AOD 1.11 Control standard (50 ml) \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eIn order to operate the decomposition system properly it is required to have a protective device in place in order to safely ignite the sample. \u003cbr data-mce-fragment=\"1\"\u003eIf such protective device is already in place, please add the accessory AOD 1.3 remote ignition head. \u003cbr data-mce-fragment=\"1\"\u003eIf no protective device is in place, our AOD 1.3 protective device could be chosen for example. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e- Quantitative decomposition of all halogens, sulfur, as well as volatile metals, e.g. As and Hg \u003cbr data-mce-fragment=\"1\"\u003e- Absorption of the combustion products in an aqueous medium \u003cbr data-mce-fragment=\"1\"\u003e- Catalytic support of the oxidation process with auto-regenerating catalytic inner surface of the decomposition vessel \u003cbr data-mce-fragment=\"1\"\u003e- Pressure vessel of high-grade stainless steel \u003cbr data-mce-fragment=\"1\"\u003e- Decomposition temperature up to 1200 °C \u003cbr data-mce-fragment=\"1\"\u003e- Max. operating pressure during decomposition 195 bar \u003cbr data-mce-fragment=\"1\"\u003e- Decomposition time \u0026lt; 3 min \u003cbr data-mce-fragment=\"1\"\u003e- The decomposition vessel can be changed over to use combustible crucibles C 14 \u003cbr data-mce-fragment=\"1\"\u003e- Control standards for Cl, S ( AOD 1.11) \u003cbr data-mce-fragment=\"1\"\u003e- Introduction of the combustion gases into the absorption solution via venting station C 7030 \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003ePrinciple and function are based on the method of the combustion in the bomb calorimeter and validated according \u003cbr data-mce-fragment=\"1\"\u003eDIN 51577-1 \u003cbr data-mce-fragment=\"1\"\u003eOther relevant standards are for example: \u003cbr data-mce-fragment=\"1\"\u003e- DIN \/ EN 14582, determination characteristics of waste, halogen and sulfur content \u003cbr data-mce-fragment=\"1\"\u003e- DIN 51527, Testing of solid samples, determination of chlorine content","published_at":"2021-06-09T13:06:02+12:00","created_at":"2021-06-09T12:53:50+12:00","vendor":"IKA","type":"Decomposition Systems","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Decomposition Systems"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39417936412771,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA AOD 1 Decomposition system","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1Decompositionsystem_1.jpg?v=1623200033"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1Decompositionsystem_1.jpg?v=1623200033","options":["Title"],"media":[{"alt":null,"id":20603912814691,"position":1,"preview_image":{"aspect_ratio":1.04,"height":962,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1Decompositionsystem_1.jpg?v=1623200033"},"aspect_ratio":1.04,"height":962,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/AOD1Decompositionsystem_1.jpg?v=1623200033","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"The AOD 1 is used for oxidative decomposition of solid and liquid organic and partially inorganic samples under pressure in a closed system. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eThe system consists of: \u003cbr data-mce-fragment=\"1\"\u003eAOD 1.1 Decomposition vessel, C 48 Oxygen station, AOD 1.2 External ignition unit, AOD 1.11 Control standard (50 ml) \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eIn order to operate the decomposition system properly it is required to have a protective device in place in order to safely ignite the sample. \u003cbr data-mce-fragment=\"1\"\u003eIf such protective device is already in place, please add the accessory AOD 1.3 remote ignition head. \u003cbr data-mce-fragment=\"1\"\u003eIf no protective device is in place, our AOD 1.3 protective device could be chosen for example. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003e- Quantitative decomposition of all halogens, sulfur, as well as volatile metals, e.g. As and Hg \u003cbr data-mce-fragment=\"1\"\u003e- Absorption of the combustion products in an aqueous medium \u003cbr data-mce-fragment=\"1\"\u003e- Catalytic support of the oxidation process with auto-regenerating catalytic inner surface of the decomposition vessel \u003cbr data-mce-fragment=\"1\"\u003e- Pressure vessel of high-grade stainless steel \u003cbr data-mce-fragment=\"1\"\u003e- Decomposition temperature up to 1200 °C \u003cbr data-mce-fragment=\"1\"\u003e- Max. operating pressure during decomposition 195 bar \u003cbr data-mce-fragment=\"1\"\u003e- Decomposition time \u0026lt; 3 min \u003cbr data-mce-fragment=\"1\"\u003e- The decomposition vessel can be changed over to use combustible crucibles C 14 \u003cbr data-mce-fragment=\"1\"\u003e- Control standards for Cl, S ( AOD 1.11) \u003cbr data-mce-fragment=\"1\"\u003e- Introduction of the combustion gases into the absorption solution via venting station C 7030 \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003ePrinciple and function are based on the method of the combustion in the bomb calorimeter and validated according \u003cbr data-mce-fragment=\"1\"\u003eDIN 51577-1 \u003cbr data-mce-fragment=\"1\"\u003eOther relevant standards are for example: \u003cbr data-mce-fragment=\"1\"\u003e- DIN \/ EN 14582, determination characteristics of waste, halogen and sulfur content \u003cbr data-mce-fragment=\"1\"\u003e- DIN 51527, Testing of solid samples, determination of chlorine content"}

IKA AOD 1 Decomposition system
The AOD 1 is used for oxidative decomposition of solid and liquid organic and partially inorganic samples under pressure in a closed system. The system consists of: AOD 1.1 Decomposition vessel, C 48 Oxygen station, AOD 1.2 External ignition unit, AOD 1.11 Control standard (50 ml) In order to operate the decomposition system properly it is req...
More Info









