{"id":4425439707235,"title":"Heal Force HFSAFE Class II B2 Biological","handle":"heal-force-hfsafe-900lcb2-1200lcb2-1500lcb2-1800lcb2","description":"\u003cp\u003e\u003cspan\u003eWith an extensive track record of safety, reliability and performance, HFsafe LCB2 cabinets make ideal investments for a wide range of applications including work with infectious agents that require Biosafety Level 1, 2 or 3 containment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003ePatented Flow-saFe system automatically balances the downflow and inflow velocities to maintain user and sample protection.\u003c\/li\u003e\n\u003cli\u003eYou can keep a constant check on the airflow, window position etc.- anytime, anywhere.\u003c\/li\u003e\n\u003cli\u003eWhen the front sash is closed, our intelligent speed control automatically reduces flow speed.\u003c\/li\u003e\n\u003cli\u003eNegative-pressure, dual side walls prevent the possibility of contamination from leaks to the exterior environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eEnhanced comfort and convenience \u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003e10 ° backward-slanted safety grade glass provides protection with more comfortable viewing than vertical sashes.\u003c\/li\u003e\n\u003cli\u003eCounterbalanced sliding sash can be raised to a maximum height for easy introduction of large items.\u003c\/li\u003e\n\u003cli\u003eThe radiused edge prevents the potentially dangerous practice of placing materials in this area.\u003c\/li\u003e\n\u003cli\u003eConstructed of seamless, non-porous, autoclavable Type 304 stainless steel for working plate, one-piece side\/rear walls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eUV Decontamination\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eProgrammable UV light timer simplifies operation while extending life time\u003c\/li\u003e\n\u003cli\u003ePowerful UV irradiation ensures thorough disinfection of the complete chamber.\u003c\/li\u003e\n\u003cli\u003eUV lamp with interlocking safety switch function is designed for your safety.\u003c\/li\u003e\n\u003cli\u003eUnique hidden UV lamp protects operator’ s eyes from hurt.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eEasy to Clean\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eThe cabinet work zone has no welded joints to collect contaminants or rust.\u003c\/li\u003e\n\u003cli\u003eDetails of cabinet developed further to ensure easier cleaning with normal cleaning solvents\u003c\/li\u003e\n\u003cli\u003eAirflow laminator protects the filter surface during wipe cleaning.\u003c\/li\u003e\n\u003cli\u003eOptional multiple piece stainless steel work surface is easier to remove and put into autoclave \/ washer.\u003c\/li\u003e\n\u003cli\u003eBottom sink is made of stainless steel type 304 with round corners and draining valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eHow to set a new bechmark for the whole industry?\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eSupply and exhaust filters provide 99.999% typical efficiency for particle size of 0.1 to 0.2 microns, providing superior product protection over conventional HEPA filters.\u003c\/li\u003e\n\u003cli\u003eGerman made ebm-papst motors selected for energy efficiency, compact design, and flat profile.\u003c\/li\u003e\n\u003cli\u003eTemperature-compensated airflow sensors monitor the airflow constantly to ensure safe operating conditions are maintained.\u003c\/li\u003e\n\u003cli\u003eTwo independent sensors (downflow\/exhaust airflow) mean double security.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eFriendly Communication\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003e LCD is mounted at eye level for at-a-glance viewing of airflow, operating parameters, and alarm messages.\u003c\/li\u003e\n\u003cli\u003e The intuitive interface delivers a constant read-out of working area temperature, air velocity\/volume, filter life span, total running time.\u003c\/li\u003e\n\u003cli\u003e Patented filter life indicator is designed to measure filter life according to actual condition of membrane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eExhaust Connection Design\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eIf biosafety cabinets are used for minute quantities of volatile toxic chemicals and trace amounts of radionucleotides required as an adjunct to microbiological research, they must be exhausted through properly functioning exhaust canopies.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eIndependent exhaust system                \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eCentral exhaust system case 1                        \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eCentral exhaust system case 2\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eCentral exhaust system case1: Applicable to the condition where air volume and pressure of central exhaust system are sufficient\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eCentral exhaust system case2: Applicable to the condition where air volume is sufficient, while pressure of central exhaust system is not enough. Need to choose special designed exhaust blower to support the pressure requirement.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eConstant air flow valve\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eClass II type B2 biosafety cabinet should be normally working under the condition when the exhaust air volume is consistent\u003c\/li\u003e\n\u003cli\u003eIt minimizes the potential air velocity fluctuation during work. Constant air flow guarantees your safety!\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eElectric anti blow back valve \u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eElectric anti blow back valve prevents air flow back to safety cabinet and cause air fluctuation\u003c\/li\u003e\n\u003cli\u003eValve can be synchronized open or closed with the power switch button of the cabinet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eComprehensive Performance Testing\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eEvery HFsafe model manufactured by Heal Force is individually tested, documented by serial number and validated with the following test methods.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eInflow\/Downflow velocity                            \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eAir particle count test          \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eUV radiation test\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eScan test for filters                            \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eVibration test                                            \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eIllumination test\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eKI Discus containment test according to EN12469 (Potassium Iodide)\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eOne of the few companies in the world equipped to perform the KI Discus test for validating the operator\/personnel protection capabilities \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eExcellent correlation with the microbiological test method for operator protection, and is useful for validating the actual containment performance of the cabinet on-site.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe KI-Discus takes only 45 minutes as opposed to 2 days for microbiological testing. Thus, Each HFsafe model is factory tested on a sampling basis using the KI-Discus method for operator safety.\u003c\/p\u003e","published_at":"2022-07-09T18:58:39+12:00","created_at":"2019-12-13T13:47:48+13:00","vendor":"Heal Force","type":"Biosafety Cabinets","tags":["Category_Biosafety Cabinets","Features_Ducted","Length_1200mm","Length_1500mm","Length_1800mm","Length_900mm","Manufacturer_Heal Force","Type_Class 2 Biosafety Cabinets"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":45359036334376,"title":"Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 900mm","option1":"Biosafety Cabinets","option2":"Class 2 Biosafety Cabinets","option3":"900mm","sku":"900LCB2","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Heal Force HFSAFE Class II B2 Biological - Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 900mm","public_title":"Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 900mm","options":["Biosafety Cabinets","Class 2 Biosafety Cabinets","900mm"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":45359036367144,"title":"Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 1200mm","option1":"Biosafety Cabinets","option2":"Class 2 Biosafety Cabinets","option3":"1200mm","sku":"1200LCB3","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Heal Force HFSAFE Class II B2 Biological - Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 1200mm","public_title":"Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 1200mm","options":["Biosafety Cabinets","Class 2 Biosafety Cabinets","1200mm"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":45359036399912,"title":"Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 1500mm","option1":"Biosafety Cabinets","option2":"Class 2 Biosafety Cabinets","option3":"1500mm","sku":"1500LCB4","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Heal Force HFSAFE Class II B2 Biological - Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 1500mm","public_title":"Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 1500mm","options":["Biosafety Cabinets","Class 2 Biosafety Cabinets","1500mm"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]},{"id":45359036432680,"title":"Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 1800mm","option1":"Biosafety Cabinets","option2":"Class 2 Biosafety Cabinets","option3":"1800mm","sku":"1800LCB5","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Heal Force HFSAFE Class II B2 Biological - Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 1800mm","public_title":"Biosafety Cabinets \/ Class 2 Biosafety Cabinets \/ 1800mm","options":["Biosafety Cabinets","Class 2 Biosafety Cabinets","1800mm"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/Untitleddesign_3_-min_e340fd1e-47c1-431a-b7a3-b50bef128695.png?v=1659156994"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/Untitleddesign_3_-min_e340fd1e-47c1-431a-b7a3-b50bef128695.png?v=1659156994","options":["Category","Type","Length"],"media":[{"alt":null,"id":21779210240099,"position":1,"preview_image":{"aspect_ratio":1.0,"height":2048,"width":2048,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/Untitleddesign_3_-min_e340fd1e-47c1-431a-b7a3-b50bef128695.png?v=1659156994"},"aspect_ratio":1.0,"height":2048,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/Untitleddesign_3_-min_e340fd1e-47c1-431a-b7a3-b50bef128695.png?v=1659156994","width":2048}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eWith an extensive track record of safety, reliability and performance, HFsafe LCB2 cabinets make ideal investments for a wide range of applications including work with infectious agents that require Biosafety Level 1, 2 or 3 containment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003ePatented Flow-saFe system automatically balances the downflow and inflow velocities to maintain user and sample protection.\u003c\/li\u003e\n\u003cli\u003eYou can keep a constant check on the airflow, window position etc.- anytime, anywhere.\u003c\/li\u003e\n\u003cli\u003eWhen the front sash is closed, our intelligent speed control automatically reduces flow speed.\u003c\/li\u003e\n\u003cli\u003eNegative-pressure, dual side walls prevent the possibility of contamination from leaks to the exterior environment.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eEnhanced comfort and convenience \u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003e10 ° backward-slanted safety grade glass provides protection with more comfortable viewing than vertical sashes.\u003c\/li\u003e\n\u003cli\u003eCounterbalanced sliding sash can be raised to a maximum height for easy introduction of large items.\u003c\/li\u003e\n\u003cli\u003eThe radiused edge prevents the potentially dangerous practice of placing materials in this area.\u003c\/li\u003e\n\u003cli\u003eConstructed of seamless, non-porous, autoclavable Type 304 stainless steel for working plate, one-piece side\/rear walls.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eUV Decontamination\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eProgrammable UV light timer simplifies operation while extending life time\u003c\/li\u003e\n\u003cli\u003ePowerful UV irradiation ensures thorough disinfection of the complete chamber.\u003c\/li\u003e\n\u003cli\u003eUV lamp with interlocking safety switch function is designed for your safety.\u003c\/li\u003e\n\u003cli\u003eUnique hidden UV lamp protects operator’ s eyes from hurt.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eEasy to Clean\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eThe cabinet work zone has no welded joints to collect contaminants or rust.\u003c\/li\u003e\n\u003cli\u003eDetails of cabinet developed further to ensure easier cleaning with normal cleaning solvents\u003c\/li\u003e\n\u003cli\u003eAirflow laminator protects the filter surface during wipe cleaning.\u003c\/li\u003e\n\u003cli\u003eOptional multiple piece stainless steel work surface is easier to remove and put into autoclave \/ washer.\u003c\/li\u003e\n\u003cli\u003eBottom sink is made of stainless steel type 304 with round corners and draining valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eHow to set a new bechmark for the whole industry?\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eSupply and exhaust filters provide 99.999% typical efficiency for particle size of 0.1 to 0.2 microns, providing superior product protection over conventional HEPA filters.\u003c\/li\u003e\n\u003cli\u003eGerman made ebm-papst motors selected for energy efficiency, compact design, and flat profile.\u003c\/li\u003e\n\u003cli\u003eTemperature-compensated airflow sensors monitor the airflow constantly to ensure safe operating conditions are maintained.\u003c\/li\u003e\n\u003cli\u003eTwo independent sensors (downflow\/exhaust airflow) mean double security.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eFriendly Communication\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003e LCD is mounted at eye level for at-a-glance viewing of airflow, operating parameters, and alarm messages.\u003c\/li\u003e\n\u003cli\u003e The intuitive interface delivers a constant read-out of working area temperature, air velocity\/volume, filter life span, total running time.\u003c\/li\u003e\n\u003cli\u003e Patented filter life indicator is designed to measure filter life according to actual condition of membrane.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eExhaust Connection Design\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eIf biosafety cabinets are used for minute quantities of volatile toxic chemicals and trace amounts of radionucleotides required as an adjunct to microbiological research, they must be exhausted through properly functioning exhaust canopies.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eIndependent exhaust system                \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eCentral exhaust system case 1                        \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eCentral exhaust system case 2\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eCentral exhaust system case1: Applicable to the condition where air volume and pressure of central exhaust system are sufficient\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eCentral exhaust system case2: Applicable to the condition where air volume is sufficient, while pressure of central exhaust system is not enough. Need to choose special designed exhaust blower to support the pressure requirement.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eConstant air flow valve\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eClass II type B2 biosafety cabinet should be normally working under the condition when the exhaust air volume is consistent\u003c\/li\u003e\n\u003cli\u003eIt minimizes the potential air velocity fluctuation during work. Constant air flow guarantees your safety!\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eElectric anti blow back valve \u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eElectric anti blow back valve prevents air flow back to safety cabinet and cause air fluctuation\u003c\/li\u003e\n\u003cli\u003eValve can be synchronized open or closed with the power switch button of the cabinet\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"font-weight: 400;\"\u003e\u003cb\u003e\u003cstrong\u003eComprehensive Performance Testing\u003c\/strong\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eEvery HFsafe model manufactured by Heal Force is individually tested, documented by serial number and validated with the following test methods.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eInflow\/Downflow velocity                            \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eAir particle count test          \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eUV radiation test\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eScan test for filters                            \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eVibration test                                            \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eIllumination test\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003e \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eKI Discus containment test according to EN12469 (Potassium Iodide)\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eOne of the few companies in the world equipped to perform the KI Discus test for validating the operator\/personnel protection capabilities \u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eExcellent correlation with the microbiological test method for operator protection, and is useful for validating the actual containment performance of the cabinet on-site.\u003c\/p\u003e\n\u003cp style=\"font-weight: 400;\"\u003eThe KI-Discus takes only 45 minutes as opposed to 2 days for microbiological testing. Thus, Each HFsafe model is factory tested on a sampling basis using the KI-Discus method for operator safety.\u003c\/p\u003e"}

Heal Force HFSAFE Class II B2 Biological

Product Description

With an extensive track record of safety, reliability and performance, HFsafe LCB2 cabinets make ideal investments for a wide range of applications including work with infectious agents that require Biosafety Level 1, 2 or 3 containment.

  • Patented Flow-saFe system automatically balances the downflow and inflow velocities to maintain user and sample protection.
  • You can keep a constant check on the airflow, window position etc.- anytime, anywhere.
  • When the front sash is closed, our intelligent speed control automatically reduces flow speed.
  • Negative-pressure, dual side walls prevent the possibility of contamination from leaks to the exterior environment.

 

Enhanced comfort and convenience 

  • 10 ° backward-slanted safety grade glass provides protection with more comfortable viewing than vertical sashes.
  • Counterbalanced sliding sash can be raised to a maximum height for easy introduction of large items.
  • The radiused edge prevents the potentially dangerous practice of placing materials in this area.
  • Constructed of seamless, non-porous, autoclavable Type 304 stainless steel for working plate, one-piece side/rear walls.

 

UV Decontamination

  • Programmable UV light timer simplifies operation while extending life time
  • Powerful UV irradiation ensures thorough disinfection of the complete chamber.
  • UV lamp with interlocking safety switch function is designed for your safety.
  • Unique hidden UV lamp protects operator’ s eyes from hurt.

 

Easy to Clean

  • The cabinet work zone has no welded joints to collect contaminants or rust.
  • Details of cabinet developed further to ensure easier cleaning with normal cleaning solvents
  • Airflow laminator protects the filter surface during wipe cleaning.
  • Optional multiple piece stainless steel work surface is easier to remove and put into autoclave / washer.
  • Bottom sink is made of stainless steel type 304 with round corners and draining valves

 

How to set a new bechmark for the whole industry?

  • Supply and exhaust filters provide 99.999% typical efficiency for particle size of 0.1 to 0.2 microns, providing superior product protection over conventional HEPA filters.
  • German made ebm-papst motors selected for energy efficiency, compact design, and flat profile.
  • Temperature-compensated airflow sensors monitor the airflow constantly to ensure safe operating conditions are maintained.
  • Two independent sensors (downflow/exhaust airflow) mean double security.

 

Friendly Communication

  •  LCD is mounted at eye level for at-a-glance viewing of airflow, operating parameters, and alarm messages.
  •  The intuitive interface delivers a constant read-out of working area temperature, air velocity/volume, filter life span, total running time.
  •  Patented filter life indicator is designed to measure filter life according to actual condition of membrane.

 

Exhaust Connection Design

If biosafety cabinets are used for minute quantities of volatile toxic chemicals and trace amounts of radionucleotides required as an adjunct to microbiological research, they must be exhausted through properly functioning exhaust canopies.

Independent exhaust system                

Central exhaust system case 1                        

Central exhaust system case 2

Central exhaust system case1: Applicable to the condition where air volume and pressure of central exhaust system are sufficient

Central exhaust system case2: Applicable to the condition where air volume is sufficient, while pressure of central exhaust system is not enough. Need to choose special designed exhaust blower to support the pressure requirement.

 

Constant air flow valve

  • Class II type B2 biosafety cabinet should be normally working under the condition when the exhaust air volume is consistent
  • It minimizes the potential air velocity fluctuation during work. Constant air flow guarantees your safety!

Electric anti blow back valve 

  • Electric anti blow back valve prevents air flow back to safety cabinet and cause air fluctuation
  • Valve can be synchronized open or closed with the power switch button of the cabinet

Comprehensive Performance Testing

Every HFsafe model manufactured by Heal Force is individually tested, documented by serial number and validated with the following test methods.

Inflow/Downflow velocity                            

Air particle count test          

UV radiation test

Scan test for filters                            

Vibration test                                            

Illumination test

 

KI Discus containment test according to EN12469 (Potassium Iodide)

One of the few companies in the world equipped to perform the KI Discus test for validating the operator/personnel protection capabilities 

Excellent correlation with the microbiological test method for operator protection, and is useful for validating the actual containment performance of the cabinet on-site.

The KI-Discus takes only 45 minutes as opposed to 2 days for microbiological testing. Thus, Each HFsafe model is factory tested on a sampling basis using the KI-Discus method for operator safety.

This product is available upon request. Contact us for more information.