Email info@acornsci.com for orders and inquiries.

{"id":1582172997,"title":"HANNA HI 9147-15 Dissolved Oxygen Meter for Aquaculture","handle":"hi9147-15","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned specifically for aquaculture\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan id=\"gvow3532ka0_1\" class=\"gvow3532ka0\"\u003eGalvanic\u003c\/span\u003e DO probe\u003c\/li\u003e\n\u003cli\u003eBacklit LCD\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eManual salinity and altitude compensation\u003c\/li\u003e\n\u003cli\u003eWater-resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eHI 9147 is designed for aquaculture applications. This unit is unique among our family of DO meters as it is supplied with a galvanic \u003cspan id=\"gvow3532ka0_3\" class=\"gvow3532ka0\"\u003eprobe\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike polarographic probes. galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time. pick it up and measure on demand.\u003c\/p\u003e\n\u003cp\u003eHI 9147 is a must have for DO sensitive organisms or high bio-load environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 9147-04 is supplied with HI 76409\/4 probe with 4 m (13’) \u003cspan id=\"gvow3532ka0_2\" class=\"gvow3532ka0\"\u003ecable\u003c\/span\u003e and spare membranes (2). electrolyte solution (30 mL). batteries. screwdriver and instructions. \u003cbr\u003eHI 9147-10 is supplied with HI 76409\/10 probe with 10 m (32.8’) cable and spare membranes (5). electrolyte solution (30 mL). batteries. screwdriver and instructions. \u003cbr\u003eHI 9147-15 is supplied with HI 76409\/15 probe with 15 m (49.2’) cable and spare membranes (5). electrolyte solution (30 mL). batteries. screwdriver and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 600 %\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5.0 to 50.0°C (32.0 to 122.0ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mg\/L (ppm) or 1%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (1ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1% of reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C (1ºF) (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003emanual. in saturated air\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. -5 to 50°C (23°F to 122°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 4000 m (resolution 100 m)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 51 g\/L (ppt) (1 g\/L resolution)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/\u003cbr\u003eLife\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AAA (3) \/ approx. 1.000 hours of continuous use without backlight\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 g (15.9 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSolutions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207042S\"\u003eHI 7042S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution for Galvanic Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207040L\"\u003eHI 7040L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eZero Oxygen Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessories\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409-0\"\u003eHI 76409-0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eProtective Sleeve for HI 76409 DO Probe Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409A\/P\"\u003eHI 76409A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProbes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409\/4\"\u003eHI 76409\/4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic DO Probe with Protective Cap. 4 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409\/10\"\u003eHI 76409\/10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic DO Probe with Protective Cap. 10 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2016-12-14T10:03:00+13:00","created_at":"2015-09-01T15:16:39+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Dissolved Oxygen"],"price":49900,"price_min":49900,"price_max":49900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857306373,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI9147-15","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 9147-15 Dissolved Oxygen Meter for Aquaculture","public_title":null,"options":["Default Title"],"price":49900,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi9147_200_2015.jpeg?v=1443495725"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi9147_200_2015.jpeg?v=1443495725","options":["Title"],"media":[{"alt":null,"id":21302771811,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi9147_200_2015.jpeg?v=1443495725"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi9147_200_2015.jpeg?v=1443495725","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned specifically for aquaculture\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan id=\"gvow3532ka0_1\" class=\"gvow3532ka0\"\u003eGalvanic\u003c\/span\u003e DO probe\u003c\/li\u003e\n\u003cli\u003eBacklit LCD\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eManual salinity and altitude compensation\u003c\/li\u003e\n\u003cli\u003eWater-resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eHI 9147 is designed for aquaculture applications. This unit is unique among our family of DO meters as it is supplied with a galvanic \u003cspan id=\"gvow3532ka0_3\" class=\"gvow3532ka0\"\u003eprobe\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike polarographic probes. galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time. pick it up and measure on demand.\u003c\/p\u003e\n\u003cp\u003eHI 9147 is a must have for DO sensitive organisms or high bio-load environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 9147-04 is supplied with HI 76409\/4 probe with 4 m (13’) \u003cspan id=\"gvow3532ka0_2\" class=\"gvow3532ka0\"\u003ecable\u003c\/span\u003e and spare membranes (2). electrolyte solution (30 mL). batteries. screwdriver and instructions. \u003cbr\u003eHI 9147-10 is supplied with HI 76409\/10 probe with 10 m (32.8’) cable and spare membranes (5). electrolyte solution (30 mL). batteries. screwdriver and instructions. \u003cbr\u003eHI 9147-15 is supplied with HI 76409\/15 probe with 15 m (49.2’) cable and spare membranes (5). electrolyte solution (30 mL). batteries. screwdriver and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 600 %\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5.0 to 50.0°C (32.0 to 122.0ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mg\/L (ppm) or 1%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (1ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1% of reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C (1ºF) (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003emanual. in saturated air\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. -5 to 50°C (23°F to 122°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 4000 m (resolution 100 m)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 51 g\/L (ppt) (1 g\/L resolution)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/\u003cbr\u003eLife\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AAA (3) \/ approx. 1.000 hours of continuous use without backlight\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 g (15.9 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSolutions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207042S\"\u003eHI 7042S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution for Galvanic Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207040L\"\u003eHI 7040L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eZero Oxygen Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessories\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409-0\"\u003eHI 76409-0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eProtective Sleeve for HI 76409 DO Probe Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409A\/P\"\u003eHI 76409A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProbes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409\/4\"\u003eHI 76409\/4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic DO Probe with Protective Cap. 4 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409\/10\"\u003eHI 76409\/10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic DO Probe with Protective Cap. 10 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 9147-15 Dissolved Oxygen Meter for Aquaculture

Product Description

 

  • Designed specifically for aquaculture
  • Galvanic DO probe
  • Backlit LCD
  • Automatic Temperature Compensation
  • Manual salinity and altitude compensation
  • Water-resistant


HI 9147 is designed for aquaculture applications. This unit is unique among our family of DO meters as it is supplied with a galvanic probe.

Unlike polarographic probes. galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time. pick it up and measure on demand.

HI 9147 is a must have for DO sensitive organisms or high bio-load environments.

 

 

Order Information:
HI 9147-04 is supplied with HI 76409/4 probe with 4 m (13’) cable and spare membranes (2). electrolyte solution (30 mL). batteries. screwdriver and instructions. 
HI 9147-10 is supplied with HI 76409/10 probe with 10 m (32.8’) cable and spare membranes (5). electrolyte solution (30 mL). batteries. screwdriver and instructions. 
HI 9147-15 is supplied with HI 76409/15 probe with 15 m (49.2’) cable and spare membranes (5). electrolyte solution (30 mL). batteries. screwdriver and instructions.

SPECIFICATIONS:

Range O2 0.0 to 50.0 mg/L (ppm)
  % Saturation O2 0 to 600 %
  Temperature -5.0 to 50.0°C (32.0 to 122.0ºF)
Resolution O2 0.1 mg/L (ppm) or 1%
  Temperature 0.1°C (1ºF)
Accuracy (@20°C) O2 ±1% of reading
  Temperature ±0.2°C (1ºF) (excluding probe error)
Calibration   manual. in saturated air
Temperature
Compensation
  automatic. -5 to 50°C (23°F to 122°F)
Salinity
Compensation
  0 to 4000 m (resolution 100 m)
Salinity
Compensation
  0 to 51 g/L (ppt) (1 g/L resolution)
Battery Type /
Life
  1.5V AAA (3) / approx. 1.000 hours of continuous use without backlight
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)
Weight   450 g (15.9 oz.)

 

Solutions
HI 7042S Electrolyte Solution for Galvanic Probes
HI 7040L Zero Oxygen Solution
Accessories
HI 76409-0 Protective Sleeve for HI 76409 DO Probe Series
HI 76409A/P Membranes for DO Probes
Probes
HI 76409/4 Galvanic DO Probe with Protective Cap. 4 m cable
HI 76409/10 Galvanic DO Probe with Protective Cap. 10 m cable

 

This product is available upon request. Contact us for more information.