{"title":"Electrochemical - Dissolved Oxygen","description":"","products":[{"product_id":"hi-9146-04","title":"HANNA HI 9146-04  Dissolved Oxygen \/ °C - Meter (0 to 45 mg\/L)","description":"\u003cul\u003e\n\u003cli\u003eOn-screen tutorial messages\u003c\/li\u003e\n\u003cli\u003eTwo point calibration\u003c\/li\u003e\n\u003cli\u003eAuto endpoint\u003c\/li\u003e\n\u003cli\u003eDO range up to 300%. temperature compensated\u003c\/li\u003e\n\u003cli\u003eAltitude compensation up to 4000 m\u003c\/li\u003e\n\u003cli\u003eSalinity compensation up to 80 g\/L\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration in air\u003c\/li\u003e\n\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cli\u003eLow battery indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 9146 is a water-resistant. dissolved oxygen meter that measures up to 300% saturation or 45 ppm (mg\/L) with temperature compensation and automatic calibration. It has been developed for DO and temperature measurement in water. wastewater. wine and applications such as fish farming.\u003c\/p\u003e\n\u003cp\u003eThis instrument also allows altitude compensation up to 4000 m and the ppm and % saturation are both compensated for changes in solubility of oxygen in water and for permeability of the membrane as well as the temperature effect.\u003c\/p\u003e\n\u003cp\u003eThe included polarographic probe features built-in temperature compensation and removable protective membrane cover.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 9146-04 is supplied complete with HI 76407\/4F probe with 4 m (13.1’) cable. HI 76407A membranes (2). HI 7041S electrolyte solution (30 mL). batteries. instructions and rugged carrying case. HI 9146-10 is supplied complete with HI 76407\/10F probe with 10 m (32.8’) cable. HI 76407A membranes (2). HI 7041S electrolyte solution (30 mL). batteries. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. in air. at 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 1900 m (100 m 326' resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L (1g\/L resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 76407\/4F with 4 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e4 x 1.5 AA batteries \/ approx. 200 hours of continuous use; auto-off after 4 hours of inactivity; or input for 12 Vdc power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e196 x 80 x 60 mm (7.7 x 3.1 x 2.4\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e500 g (1.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857192837,"sku":"HI 9146-04","price":1060.5,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/sauerstoff-handmessgerat-mit-4-m-kabel-sonde-1080_1-151e139489ab9a_2015.jpeg?v=1443495076"},{"product_id":"hi9147-04","title":"HANNA HI 9147-04 Dissolved Oxygen \/ °C - Meter. Galvanic DO Probe","description":"\u003cul\u003e\n\u003cli\u003eDesigned specifically for aquaculture\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eGalvanic DO probe\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBacklit LCD\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eManual salinity and altitude compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eWater-resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 9147 is designed for aquaculture applications. This unit is unique among our family of DO meters as it is supplied with a galvanic probe.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eUnlike polarographic probes. galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time. pick it up and measure on demand.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 9147 is a must have for DO sensitive organisms or high bio-load environments.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 9147-04 is supplied with HI 76409\/4 probe with 4 m (13’) cable and spare membranes (2). electrolyte solution (30 mL). batteries. screwdriver and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 600 %\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5.0 to 50.0°C (32.0 to 122.0ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mg\/L (ppm) or 1%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (1ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1% of reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C (1ºF) (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003emanual. in saturated air\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. -5 to 50°C (23°F to 122°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 4000 m (resolution 100 m)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 51 g\/L (ppt) (1 g\/L resolution)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AAA (3) \/ approx. 1.000 hours of continuous use without backlight\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 g (15.9 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857193669,"sku":"HI9147-04","price":1216.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/fischzucht-sauerstoff-handmessgerat-mit-4-m-kabel-sonde-2339_1-1_2015.jpeg?v=1443495077"},{"product_id":"hi2031b","title":"HANNA HI2031B  Refillable Conical Tip Combination pH Electrode BNC Connection","description":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003e\u003cspan class=\"bt692p4073\" id=\"bt692p4073_3\"\u003eRefillable\u003c\/span\u003e. \u003cspan class=\"bt692p4073\" id=\"bt692p4073_2\"\u003econical\u003c\/span\u003e tip combination pH electrode. designed to be used for testing of dairy and semi-solid products.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"TabbedPanels\" id=\"TabbedPanels1\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table mceItemTable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSingle. Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eceramic. single \/ 15-20 µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrolyte\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eKCl 3.5M + AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pressure\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 12 pH; -5 to 30°C (23 to 86°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip Shape\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eConic (6 x 10 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan class=\"bt692p4073\" id=\"bt692p4073_1\"\u003eTemperature Sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eGlass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eCoaxial; 1 m (3.3')\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857195141,"sku":"HI2031B","price":249.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/31gluhj8kul__sl500_aa300_51e160291c334_2015.jpeg?v=1465536521"},{"product_id":"hi9142","title":"HANNA HI 9142 Dissolved Oxygen \/ °C - Meter. PolargrapHANNA HIc Probe","description":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAffordable and efficient\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eDO probe and carrying case included\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe ever increasing demand for instant on-site analysis results has created a need for innovative and rugged portable. waterproof meters.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eField work can subject instrumentation to the inclemency of weather. Cold. rain. snow. dust and humidity can cause condensation to breech the housing. Once the housing has been compromised. the meter is susceptible to diminishing performance and life. The rugged. waterproof housing of the HI 9142 solves many of the problems of field use.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eCalibration is performed with HI 7040 zero oxygen solution. while 100% calibration is done in air.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe polarographic probe (HI 76407\/4) is accurate to 0.3 ppm and is supplied with a 4 m (13') cable that allows measurements to be taken even in hard to reach places.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 9142 is supplied with HI 76407\/4 probe with  4 m (13’) cable. 2 spare membranes. HI 7041S electrolyte solution (30 mL). calibration screwdriver. batteries. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification  :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 19.9 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5.0 to 50.0ºC (32.0 to 122.0ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (1ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1.5% F.S.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C (±1ºF) (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003emanual. at one or two points (zero and slope)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. 0 to 50°C (32 to 122°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 76407\/4 polarographic DO probe with internal temperature sensor. DIN connector and 4 m (13’) cable\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AAA (3) \/ approximately 1.000 hours of continuous use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e300 g (10.6 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857195397,"sku":"HI9142","price":868.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/basic-sauerstoffhandmessgerat-1078_1-1_2015.jpeg?v=1443495079"},{"product_id":"hi98186-02","title":"HANNA HI 98186-02 Dissolved Oxygen \u0026 BOD Meter \/ °C - Meter. polarograpHANNA HIc DO probe","description":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eExtended DO range up to 50 ppm and 600% saturation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBuilt-in barometer\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eSalinity. pressure and temperature compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBacklit. graphic LCD display\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eCalibration reminder\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eLog on demand (400 samples)\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAuto HOLD\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eGLP features\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003ePC connectivity via USB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 98186 portable Dissolved Oxygen Meter has extended ranges of up to 50 ppm or 600% saturation. This instrument includes barometric pressure measurement and calibration with a user selectable unit (mmHg. atm. mbar. psi. kPa) as well as a 1 or 2 point temperature calibration. Salinity. pressure and temperature compensations enhance the precision of your readings.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eWith its internal barometer. the instrument is able to automatically compensate for changes in barometric pressure so there is no need for charts. altitude information or external barometric pressure information. Salinity compensation in water allows direct determination of dissolved oxygen in saline waters.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eOther features include measurement and methods for BOD (biochemical oxygen demand). OUR (oxygen uptake rate). and SOUR (specific oxygen uptake rate).\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 98186’s log on-demand features allows users to store up to 400 samples that can be later transferred to a PC with the HI?920013 USB cable and HI 92000 software.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eAn “Out Of Calibration Range Warning” can be activated to alert the user in the event that a reading is taken too far from the calibration's periphery. A combination of dedicated and soft keys allows easy. intuitive operation in a choice of languages. Comprehensive GLP data is directly accessible by pressing the GLP key and a contextual Help menu can be access to obtain on-screen information and assistance about each feature at the touch of a button.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eDesigned for field use. this instrument can be easily operated with one hand and is housed in a rugged carrying case. The inductive charger can either be plugged into a standard 115V socket with the adapter included or a 12 VDC source. such as a car's 12 V accessory outlet.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 98186-02 (230V) is supplied with HI 76407\/4F DO probe. spare membranes (2). HI 7041S electrolyte solution (30 mL). rechargeable batteries. HI 710042 inductive battery charger with power adapter. 12 VDC adapter. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_98186.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 50.00 mg\/L (ppm); 0.0 to 600.0 % saturation\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 to 850 mmHg\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 mg\/L (ppm); 0.1% saturation\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1 mm Hg\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C\/°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1.5% of reading ±1 digit\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e± 3 mmHg within ±15% from the calibration point\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C\/±0.4°F (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edirect DO; BOD (biochemical oxygen demand);  OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e automatic one or two point at 100 % (8.26 mg\/L) and 0 %  (0 mg\/L).; manual one point using a value entered  by the user in % saturation or mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eone point at any in range pressure value\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eone or two point at any in range temperature value\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from 450 to 850 mmHg\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSalinity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from 0 to 70 g\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from 0.0 to 50.0 ºC (32.0 to 122.0 ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 76407\/4F polarographic DO probe with protective sleeve. internal  temperature sensor. DIN connector and 4m (13’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003elog on demand. 400 samples\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eopto-isolated USB (with HI?92000 software)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.2V (4) AA rechargeable batteries\/approximately 200 hours  of continuous use without backlight\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003euser selectable: 5. 10. 30. 60 min or can be disabled\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 – 50 ºC (32 – 122 ºF) RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e 525 g (1.1 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857195973,"sku":"HI98186-02","price":0.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/sauerstoff-handmessgerat-mit-pc-interface-1476_1-1_2015.jpeg?v=1443495080"},{"product_id":"hi2400-02","title":"HANNA HI 2400-02 Laboratory Dissolved Oxygen with PC Interface. 230V","description":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eDO range up to 300%\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAltitude compensation up to 4000 m\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eSalinity compensation up to 40 g\/L\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic temperature compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAutomatic calibration in air\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003ePC compatible via USB\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eDatalogging and storage up to 8000 samples\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eGLP Features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 2400 is a dissolved oxygen benchtop meter with automatic calibration and % or mg\/L (ppm) measurement range. The measurement is automatically compensated for altitude and salinity compensation based on the user settings for altitude up to 4000 m and 40 g\/L for salinity.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eCalibration is performed at one or two points at 0% using HANNA’s HI 7040 solution or 100% in air.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eMeasurements are automatically temperature compensated by using the polarographic DO probe with built-in temperature sensor. This probe features screw cap membranes for easy replacement.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eWith a built-in logging function. measurements are stored in non volatile memory. and can be transferred to a PC through the USB port using the optional HI 92000 software and HI 920013 USB cable. The software is provided with an exclusive online guide of all the commands available and allows data printing. plotting and exporting.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe 8000 record logging interval allows the possibility of process and experimental monitoring of DO. The logging interval is automatic with user selectable intervals from 5 seconds to 180 minutes according with the speed of DO variation inside the process.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 2400 also provides users with GLP (Good Laboratory Practice) capabilities. GLP is a set of functions that allow the storage and retrieval of data regarding calibration. The GLP feature provides data consistency and a calibration reminder which can be set to alert the user that too much time has elapsed since the last calibration and a new one should be performed.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 2400-02 (230V) is supplied with HI 76407\/2 dissolved oxygen probe. HI 76407A membrane caps (2). HI 7041S electrolyte solution (30 mL). 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 45.00 mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 300.0%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1.5% F.S.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1.5% F.S.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eone or two points at 0% (HI 7040 solution) and 100% (in air)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAltitude Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 4000 m (resolution 100 m)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 40 g\/L (resolution 1 g\/L)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. 0.0 to 50.0°C (32.0 to 122ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 76407\/2 polarographic DO probe with internal temperature sensor. DIN connector and 2 m (6.6’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Interval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e5. 10. 30 seconds or 1. 2. 5. 10. 15. 30. 60. 120. 180 minutes\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eopto-isolated USB\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e12 VDC adapter\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e235 x 222 x 109 mm (9.2 x 8.7 x 4.3”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.3 kg (2.9 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857196421,"sku":"HI2400-02","price":1858.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/sauerstoff-labormessgerat-mit-pc-interface-235_1-1_2015.jpeg?v=1465536562"},{"product_id":"hi-76407-2","title":"HANNA HI 76407\/2 Dissolved Oxygen Prove with 2m cable for use with HANNA HI2400","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eShielded. \u003cspan id=\"mj9f4t0s9_3\" class=\"mj9f4t0s9\"\u003ewaterproof cable\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eProtective sleeve\u003c\/li\u003e\n\u003cli\u003ePEI probe for best field protection\u003c\/li\u003e\n\u003cli\u003eLinearized and accurate \u003cspan id=\"mj9f4t0s9_1\" class=\"mj9f4t0s9\"\u003ethermistor temperature sensor\u003c\/span\u003e protected behind a stainless steel cover\u003c\/li\u003e\n\u003cli\u003eGlass encapsulated platinum cathode\u003c\/li\u003e\n\u003cli\u003eThin permeable PTFE membrane isolates the sensor elements from the testing solution. but allows oxygen to enter (HI 76407A\/P)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe HI 76407 \u003cspan id=\"mj9f4t0s9_2\" class=\"mj9f4t0s9\"\u003edissolved oxygen probe\u003c\/span\u003e is extremely rugged. making it perfect for both laboratory and field applications. Calibration is fast. simple and all DO readings are temperature compensated.\u003c\/p\u003e\n\u003cp\u003eThe pre-tensioned. ready-made PTFE membrane can be changed in a few seconds without the need to stretch and cut replacements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eFor use with HI 4421 and HI 2400 laboratory bench DO meters. 2 m (6.6') cable\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041S\"\u003eHI 7041S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041M\"\u003eHI 7041M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041L\"\u003eHI 7041L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%2076407A\/P\"\u003eHI 76407A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857199109,"sku":"HI 76407 2","price":459.33,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/76407_2015.png?v=1443495087"},{"product_id":"hi764074f","title":"HANNA HI 76407\/4F DO Probe with Protective Sleeve","description":"\u003cul\u003e\n\u003cli\u003eShielded. waterproof cable\u003c\/li\u003e\n\u003cli\u003ePEI probe for best field protection\u003c\/li\u003e\n\u003cli\u003eLinearized and accurate thermistor temperature sensor protected behind a stainless steel cover\u003c\/li\u003e\n\u003cli\u003ePermeable membrane\u003c\/li\u003e\n\u003cli\u003eGlass encapsulated platinum cathode\u003c\/li\u003e\n\u003cli\u003eHole for solution cycling\u003c\/li\u003e\n\u003cli\u003eProtective sleeve for field applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003ePerfect for laboratory and field applications. HANNA HI 76407 F Series DO probes are extremely rugged with a screw on protective sleeve. Calibration is fast and simple. and measurements are temperature compensated. The sensitive PTFE membrane can be changed in a few seconds.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   For use with HI 98186. HI 9146 and HI 9142 portable DO meters. 4 m (13') cable\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857199237,"sku":"HI764074F","price":352.93,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/f_2015.png?v=1443495089"},{"product_id":"hi76408","title":"HANNA HI 76408  THANNA HInner Lighter DO Probe for Laboratories","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eShielded. waterproof cable\u003c\/li\u003e\n\u003cli\u003eProtective sleeve\u003c\/li\u003e\n\u003cli\u003ePEI probe for best field protection\u003c\/li\u003e\n\u003cli\u003eLinearized and accurate thermistor temperature sensor protected behind a stainless steel cover\u003c\/li\u003e\n\u003cli\u003eGlass encapsulated platinum cathode\u003c\/li\u003e\n\u003cli\u003eThin permeable PTFE membrane isolates the sensor elements from the testing solution. but allows oxygen to enter (HI 76407A\/P)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe HANNA HI 76408 DO probe is rugged and perfect for both laboratory and field applications. Calibration is fast and simple. and measurements are temperature compensated. The sensitive PTFE membrane can be changed in a few seconds.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eFor use with HI 2400 DO bench meter. 1 m (3.3') cable\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eAccessories\u003c\/li\u003e\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041S\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041S\"\u003eHI 7041S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041M\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041M\"\u003eHI 7041M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041L\"\u003eHI 7041L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%2076407A\/P\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%2076407A\/P\"\u003eHI 76407A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857199493,"sku":"HI76408","price":750.03,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/8_2015.png?v=1443495091"},{"product_id":"hi-764094","title":"HANNA HI 76409\/4 Galvanic DO Probe with Protective Cap","description":"\u003cul\u003e\n\u003cli\u003eShielded. waterproof cable\u003c\/li\u003e\n\u003cli\u003eFlex protect\u003c\/li\u003e\n\u003cli\u003eStrain relief for cable\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eCathode (3.5 mm). pure silver\u003c\/li\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eUnlike polarographic probes. galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time. pick it up and measure on demand.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   For use with HI 9147 portable DO meter.  4 m (13') cable\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857199557,"sku":"HI 764094","price":352.93,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/9_2015.png?v=1443495092"},{"product_id":"hi-76409ap","title":"HANNA HI76409A\/P DO Membrane for probe HANNA HI 76409 (5 pcss)","description":"\u003cp\u003e\u003cspan class=\"hps\"\u003eHI76409A\u003c\/span\u003e \u003cspan class=\"hps\"\u003e\/ P\u003c\/span\u003e \u003cspan class=\"hps\"\u003ereplacement\u003c\/span\u003e \u003cspan class=\"hps\"\u003emembranes for\u003c\/span\u003e \u003cspan class=\"hps\"\u003eHI\u003c\/span\u003e \u003cspan class=\"hps\"\u003e76409\u003c\/span\u003e \u003cspan class=\"hps\"\u003eprobes\u003c\/span\u003e \u003cspan class=\"hps\"\u003e(5 pieces)\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857199941,"sku":"HI76409A\/P","price":0.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/ersatzmembranen-fur-hi-76409-5-stuck-937_1-1_2015.jpeg?v=1443495099"},{"product_id":"hi96732","title":"HANNA HI 96732 Dissolved Oxygen 0.0 to 10.0 mg\/lL - Portable Photometer","description":"\u003cp\u003eIn aquaculture. dissolved oxygen is arguably the most important parameter of water quality. Most species require a minimum of 3 mg\/L (ppm) DO. 8-10 mg\/L (ppm) is preferable. Unlike other gases such as nitrogen. oxygen supersaturation doesn’t usually result in gas bubble disease (“pop-eye”). so high levels generally aren’t an issue.\u003c\/p\u003e\n\u003cp\u003eThe HI 96732 measures the content of dissolved oxygen (O\u003csub\u003e2\u003c\/sub\u003e) in surface. feed. natural and waste waters in the 0.0 to 10.0 mg\/L (ppm) range.\u003c\/p\u003e\n\u003cp\u003eHI 96732 uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 96732 is supplied with sample cuvettes with caps (2). 60 mL glass bottle with stopper. 9V battery and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96732_19_11_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.2 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003elight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 466 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eModified Winkler Method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Shut off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857253765,"sku":"HI96732","price":406.6,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e50a4133e49_2015.jpeg?v=1443495386"},{"product_id":"hi9147-15","title":"HANNA HI 9147-15  Dissolved Oxygen Meter for Aquaculture","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned specifically for aquaculture\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan id=\"gvow3532ka0_1\" class=\"gvow3532ka0\"\u003eGalvanic\u003c\/span\u003e DO probe\u003c\/li\u003e\n\u003cli\u003eBacklit LCD\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eManual salinity and altitude compensation\u003c\/li\u003e\n\u003cli\u003eWater-resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eHI 9147 is designed for aquaculture applications. This unit is unique among our family of DO meters as it is supplied with a galvanic \u003cspan id=\"gvow3532ka0_3\" class=\"gvow3532ka0\"\u003eprobe\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eUnlike polarographic probes. galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time. pick it up and measure on demand.\u003c\/p\u003e\n\u003cp\u003eHI 9147 is a must have for DO sensitive organisms or high bio-load environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 9147-04 is supplied with HI 76409\/4 probe with 4 m (13’) \u003cspan id=\"gvow3532ka0_2\" class=\"gvow3532ka0\"\u003ecable\u003c\/span\u003e and spare membranes (2). electrolyte solution (30 mL). batteries. screwdriver and instructions. \u003cbr\u003eHI 9147-10 is supplied with HI 76409\/10 probe with 10 m (32.8’) cable and spare membranes (5). electrolyte solution (30 mL). batteries. screwdriver and instructions. \u003cbr\u003eHI 9147-15 is supplied with HI 76409\/15 probe with 15 m (49.2’) cable and spare membranes (5). electrolyte solution (30 mL). batteries. screwdriver and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 600 %\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5.0 to 50.0°C (32.0 to 122.0ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mg\/L (ppm) or 1%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (1ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1% of reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C (1ºF) (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003emanual. in saturated air\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. -5 to 50°C (23°F to 122°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 4000 m (resolution 100 m)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 51 g\/L (ppt) (1 g\/L resolution)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/\u003cbr\u003eLife\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AAA (3) \/ approx. 1.000 hours of continuous use without backlight\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 g (15.9 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSolutions\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207042S\"\u003eHI 7042S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution for Galvanic Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207040L\"\u003eHI 7040L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eZero Oxygen Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccessories\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409-0\"\u003eHI 76409-0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eProtective Sleeve for HI 76409 DO Probe Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409A\/P\"\u003eHI 76409A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eProbes\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409\/4\"\u003eHI 76409\/4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic DO Probe with Protective Cap. 4 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409\/10\"\u003eHI 76409\/10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic DO Probe with Protective Cap. 10 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857306373,"sku":"HI9147-15","price":499.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi9147_200_2015.jpeg?v=1443495725"},{"product_id":"hi-9146-10","title":"HANNA HI 9146-10 Portable Dissolved Oxygen Meter","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eOn-screen tutorial messages\u003c\/li\u003e\n\u003cli\u003eTwo point calibration\u003c\/li\u003e\n\u003cli\u003eAuto endpoint\u003c\/li\u003e\n\u003cli\u003eDO range up to 300%. temperature compensated\u003c\/li\u003e\n\u003cli\u003eAltitude compensation up to 4000 m\u003c\/li\u003e\n\u003cli\u003eSalinity compensation up to 80 g\/L\u003c\/li\u003e\n\u003cli\u003eAutomatic calibration in air\u003c\/li\u003e\n\u003cli\u003eGLP features\u003c\/li\u003e\n\u003cli\u003eLow battery indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 9146 is a water-resistant. dissolved oxygen meter that measures up to 300% saturation or 45 ppm (mg\/L) with temperature compensation and automatic calibration. It has been developed for DO and temperature measurement in water. wastewater. wine and applications such as fish farming.\u003c\/p\u003e\n\u003cp\u003eThis instrument also allows altitude compensation up to 4000 m and the ppm and % saturation are both compensated for changes in solubility of oxygen in water and for permeability of the membrane as well as the temperature effect.\u003c\/p\u003e\n\u003cp\u003eThe included polarographic probe features built-in temperature compensation and removable protective membrane cover.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 9146-04 is supplied complete with HI 76407\/4F probe with 4 m (13.1’) cable. HI 76407A membranes (2). HI 7041S electrolyte solution (30 mL). batteries. instructions and rugged carrying case. \u003cbr\u003eHI 9146-10 is supplied complete with HI 76407\/10F probe with 10 m (32.8’) cable. HI 76407A membranes (2). HI 7041S electrolyte solution (30 mL). batteries. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003ctd\u003e±1.5% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. in air. at 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 1900 m (100 m 326' resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L (1g\/L resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 76407\/4F with 4 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e4 x 1.5 AA batteries \/ approx. 200 hours of continuous use;\u003cbr\u003eauto-off after 4 hours of inactivity; or input for 12 Vdc power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e196 x 80 x 60 mm (7.7 x 3.1 x 2.4\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e500 g (1.1 lb.)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eElectrodes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076407\/4F\"\u003eHI 76407\/4F\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eDO Probe with Protective Sleeve. 4 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076407\/10F\"\u003eHI 76407\/10F\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eDO Probe with Protective Sleeve. 10 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207040L\"\u003eHI 7040L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eZero Oxygen Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207041M\"\u003eHI 7041M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207041L\"\u003eHI 7041L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207041S\"\u003eHI 7041S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076407A\/P\"\u003eHI 76407A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857316357,"sku":"HI 9146-10","price":1191.5,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi9146_200_2015.jpeg?v=1443495764"},{"product_id":"hi-9147-10","title":"HANNA HI 9147-10  Dissolved Oxygen Meter for Aquaculture","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned specifically for aquaculture\u003c\/li\u003e\n\u003cli\u003eGalvanic DO \u003cspan id=\"jv9mz_2\" class=\"jv9mz\"\u003eprobe\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eBacklit LCD\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eManual salinity and altitude compensation\u003c\/li\u003e\n\u003cli\u003eWater-resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eHI 9147 is designed for aquaculture applications. This unit is unique among our family of DO meters as it is supplied with a galvanic probe.\u003c\/p\u003e\n\u003cp\u003eUnlike polarographic probes. galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time. pick it up and measure on demand.\u003c\/p\u003e\n\u003cp\u003eHI 9147 is a must have for DO sensitive organisms or high bio-load environments.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 9147-04 is supplied with HI 76409\/4 probe with 4 m (13’) \u003cspan id=\"jv9mz_1\" class=\"jv9mz\"\u003ecable\u003c\/span\u003e and spare membranes (2). electrolyte solution (30 mL). batteries. screwdriver and instructions. \u003cbr\u003eHI 9147-10 is supplied with HI 76409\/10 probe with 10 m (32.8’) cable and spare membranes (5). electrolyte solution (30 mL). batteries. screwdriver and instructions. \u003cbr\u003eHI 9147-15 is supplied with HI 76409\/15 probe with 15 m (49.2’) cable and spare membranes (5). electrolyte solution (30 mL). batteries. screwdriver and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003e% Saturation O\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 600 %\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5.0 to 50.0°C (32.0 to 122.0ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mg\/L (ppm) or 1%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C (1ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eO\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1% of reading\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C (1ºF) (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003emanual. in saturated air\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. -5 to 50°C (23°F to 122°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 4000 m (resolution 100 m)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 51 g\/L (ppt) (1 g\/L resolution)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/\u003cbr\u003eLife\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AAA (3) \/ approx. 1.000 hours of continuous use without backlight\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 g (15.9 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207042S\"\u003eHI 7042S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution for Galvanic Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%207040L\"\u003eHI 7040L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eZero \u003cspan id=\"jv9mz_3\" class=\"jv9mz\"\u003eOxygen\u003c\/span\u003e Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409-0\"\u003eHI 76409-0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eProtective Sleeve for HI 76409 DO Probe Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409A\/P\"\u003eHI 76409A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eProbes\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409\/4\"\u003eHI 76409\/4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic DO Probe with Protective Cap. 4 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004002\u0026amp;ProdCode=HI%2076409\/10\"\u003eHI 76409\/10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGalvanic DO Probe with Protective Cap. 10 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857316421,"sku":"HI 9147-10","price":995.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi9147_200-1_2015.jpeg?v=1443495764"},{"product_id":"hi-7640710","title":"HANNA HI 76407\/10  Standard DO Probe. 10 m cable","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eShielded. waterproof cable\u003c\/li\u003e\n\u003cli\u003eProtective sleeve\u003c\/li\u003e\n\u003cli\u003ePEI probe for best field protection\u003c\/li\u003e\n\u003cli\u003eLinearized and accurate thermistor temperature sensor protected behind a stainless steel cover\u003c\/li\u003e\n\u003cli\u003eGlass encapsulated platinum cathode\u003c\/li\u003e\n\u003cli\u003eThin permeable PTFE membrane isolates the sensor elements from the testing solution. but allows oxygen to enter (HI 76407A\/P)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe HI 76407 dissolved oxygen probe is extremely rugged. making it perfect for both laboratory and field applications. Calibration is fast. simple and all DO readings are temperature compensated.\u003c\/p\u003e\n\u003cp\u003eThe pre-tensioned. ready-made PTFE membrane can be changed in a few seconds without the need to stretch and cut replacements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eFor use with HI 4421 and HI 2400 laboratory bench DO meters. 10 m (33') cable\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041S\"\u003eHI 7041S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041M\"\u003eHI 7041M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041L\"\u003eHI 7041L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%2076407A\/P\"\u003eHI 76407A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857316485,"sku":"HI 7640710","price":585.68,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi76407_200-1_2015.jpeg?v=1443495765"},{"product_id":"hi-7640710f","title":"HANNA HI 76407\/10F  DO Probe with Protective Sleeve. 10 m cable","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eShielded. waterproof cable\u003c\/li\u003e\n\u003cli\u003ePEI probe for best field protection\u003c\/li\u003e\n\u003cli\u003eLinearized and accurate thermistor temperature sensor protected behind a stainless steel cover\u003c\/li\u003e\n\u003cli\u003ePermeable membrane\u003c\/li\u003e\n\u003cli\u003eGlass encapsulated platinum cathode\u003c\/li\u003e\n\u003cli\u003eHole for solution cycling\u003c\/li\u003e\n\u003cli\u003eProtective sleeve for field applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003ePerfect for laboratory and field applications. HANNA HI 76407 F Series DO probes are extremely rugged with a screw on protective sleeve. Calibration is fast and simple. and measurements are temperature compensated. The sensitive PTFE membrane can be changed in a few seconds.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eFor use with HI 98186. HI 9146 and HI 9142 portable DO meters. 10 m (33') cable\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eAccessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207040L\"\u003eHI 7040L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eZero Oxygen Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041S\"\u003eHI 7041S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041M\"\u003eHI 7041M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041L\"\u003eHI 7041L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%2076407A\/P\"\u003eHI 76407A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857316549,"sku":"HI 7640710F","price":585.68,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi76407f-200-1_2015.jpeg?v=1443495766"},{"product_id":"hi-7640720","title":"HANNA HI 76407\/20  Standard DO Probe. 20 m cable","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eShielded. waterproof cable\u003c\/li\u003e\n\u003cli\u003eProtective sleeve\u003c\/li\u003e\n\u003cli\u003ePEI probe for best field protection\u003c\/li\u003e\n\u003cli\u003eLinearized and accurate thermistor temperature sensor protected behind a stainless steel cover\u003c\/li\u003e\n\u003cli\u003eGlass encapsulated platinum cathode\u003c\/li\u003e\n\u003cli\u003eThin permeable PTFE membrane isolates the sensor elements from the testing solution. but allows oxygen to enter (HI 76407A\/P)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe HI 76407 dissolved oxygen probe is extremely rugged. making it perfect for both laboratory and field applications. Calibration is fast. simple and all DO readings are temperature compensated.\u003c\/p\u003e\n\u003cp\u003eThe pre-tensioned. ready-made PTFE membrane can be changed in a few seconds without the need to stretch and cut replacements.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eFor use with HI 4421 and HI 2400 laboratory bench DO meters. 20 m (67') cable\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eAccessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041S\"\u003eHI 7041S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041M\"\u003eHI 7041M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207041L\"\u003eHI 7041L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%2076407A\/P\"\u003eHI 76407A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857316677,"sku":"HI 7640720","price":699.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi76407_200-2_2015.jpeg?v=1443495766"},{"product_id":"hi-7640720f","title":"HANNA HI 76407\/20F  DO Probe with Protective Sleeve. 20 m cable","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eShielded. waterproof cable\u003c\/li\u003e\n\u003cli\u003ePEI probe for best field protection\u003c\/li\u003e\n\u003cli\u003eLinearized and accurate thermistor temperature sensor protected behind a stainless steel cover\u003c\/li\u003e\n\u003cli\u003ePermeable membrane\u003c\/li\u003e\n\u003cli\u003eGlass encapsulated platinum cathode\u003c\/li\u003e\n\u003cli\u003eHole for solution cycling\u003c\/li\u003e\n\u003cli\u003eProtective sleeve for field applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003ePerfect for laboratory and field applications. HANNA HI 76407 F Series DO probes are extremely rugged with a screw on protective sleeve. Calibration is fast and simple. and measurements are temperature compensated. The sensitive PTFE membrane can be changed in a few seconds.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eFor use with HI 98186. HI 9146 and HI 9142 portable DO meters. 20 m (65.6') cable\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eAccessories\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027005\u0026amp;ProdCode=HI%207040L\"\u003eHI 7040L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eZero Oxygen Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027005\u0026amp;ProdCode=HI%207041S\"\u003eHI 7041S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027005\u0026amp;ProdCode=HI%207041M\"\u003eHI 7041M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027005\u0026amp;ProdCode=HI%207041L\"\u003eHI 7041L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eRefilling Electrolyte Solution. 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=027005\u0026amp;ProdCode=HI%2076407A\/P\"\u003eHI 76407A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857316805,"sku":"HI 7640720F","price":699.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi76407f-200-2_2015.jpeg?v=1443495767"},{"product_id":"hi-7640910","title":"HANNA HI 76409\/10  Galvanic DO Probe with Protective Cap. 10 m cable","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eShielded. waterproof cable\u003c\/li\u003e\n\u003cli\u003eFlex protect\u003c\/li\u003e\n\u003cli\u003eStrain relief for cable\u003c\/li\u003e\n\u003cli\u003eTemperature sensors\u003c\/li\u003e\n\u003cli\u003eCathode (3.5 mm). pure silver\u003c\/li\u003e\n\u003cli\u003eProtective cap\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eUnlike polarographic probes. galvanic DO probes require no conditioning time. When you need to measure multiple samples in a given period of time. pick it up and measure on demand.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eFor use with HI 9147 portable DO meter. 10 m (33') cable\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eAccessories\u003c\/li\u003e\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207040L\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207040L\"\u003eHI 7040L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eZero Oxygen Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207042S\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%207042S\"\u003eHI 7042S\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eElectrolyte Solution for Galvanic Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003cth\u003eAccessories\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%2076409A\/P\" data-mce-href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=004003\u0026amp;ProdCode=HI%2076409A\/P\"\u003eHI 76409A\/P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eMembranes for DO Probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":4857316869,"sku":"HI 7640910","price":469.78,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi76409_200_2015.jpeg?v=1443495768"},{"product_id":"hi76409-0","title":"HANNA HI 76409-0  Protective Sleeve for HANNA HI 76409 DO Probe Series","description":"\u003cp\u003e\u003cspan style=\"font-size: small;\"\u003e\u003c\/span\u003e\u003c\/p\u003e\u003cp\u003e\u003cspan id=\"mj9f4t0s9_1\" class=\"mj9f4t0s9\"\u003eProtective Sleeve\u003c\/span\u003e for HI 76409 DO Sensor Series\u003c\/p\u003e\u003cp\u003e \u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e1 pc.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":5764262917,"sku":"HI76409-0","price":60.8,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/schutzkappe-fur-hi-76409-936_1-1_2015.jpeg?v=1443495098"},{"product_id":"hi4421-02","title":"HANNA HI 4421-02 RESEARCH GRADE Dissolved Oxygen \u0026 BOD Meter","description":"\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eHI 4421\u003c\/strong\u003e is a research grade dissolved oxygen bench meter with extensive capabilities in measuring DO as BOD (Biological Oxygen Demand). OUR (Oxygen Uptake Rate). SOUR (Specific Oxygen Uptake Rate). atmospheric pressure and temperature. DO measurements can be performed in ppm (mg\/L) range or in % and feature automatic or manual temperature and atmospheric pressure compensation and manual salinity compensation.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eAutomatic and manual calibration of DO can be performed in one or two points using standard or user defined standards. Users can set the reading stability criteria; three modes are available: Fast. Medium and Accurate. Direct\/autohold auomatically holds the reading on display when measurement stability is reached. In direct reading mode. the user interface can be set to basic with or without GLP. graphic or logging information.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThese instruments offer multi-language support and contextual help is available through a dedicated Help key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through all measurement and calibration procedures to ensure measurements and procedures are performed properly.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe BOD. OUR and SOUR methods are supported with a dedicated tutorial and step by step indication in order to assure a full and correct reading of DO using this specific measuring method.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe DO probe is using the polarographic principal of measurement and has a built-in temperature sensor.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eUp to 10 profiles can be saved and recalled eliminating the need to reconfigure each time when a different electrode is used. User definable configurations can include reading mode: direct or BOD. OUR. and SOUR. measurement units. temperature units. stability criteria. and temperature. atmospheric pressure and salinity compensation.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThree selectable logging modes are available: Automatic. Manual and AutoHold logging. Up to 100 logging lots can be stored for automatic or manual modes. Automatic logging features a selectable area and sampling period while GLP information includes complete data about user calibration of each parameter and identification information for the instrument. user. and company. Data can be transferred to a PC via the opto-isolated PC interface via the RS232 or USB ports and HI 92000 software (optional).\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 4421-02 (230V) is supplied with HI 76408 DO probe. HI 76404N electrode holder. HI 7041S electrolyte solution (30 mL). HI 76407A membrane caps (2). 12 VDC adapter and instruction manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDissolved Oxygen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 90.00 ppm; 0.0 to 600.0 % saturation\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 to 850 mmHg; 560 to 1133 mBar\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-20.0 to 120.0°C; -4.0 to 248°F; 253.1 to 393.1 K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDissolved Oxygen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 ppm; 0.1% saturation\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1 mm Hg\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C\/°F\/K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDissolved Oxygen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1.5% of reading ±1 digit\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±3 mm Hg + 1 least significant digit\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edirect DO; BOD (biochemical oxygen demand); OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDissolved Oxygen\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic\/user standard. one or two points\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esingle point\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 50.0°C; 32.0 to 122.0°F; 237.1 to 323.1 K\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 45 g\/L (ppt)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003ethin body. polarographic dissolved oxygen probe with internal temperature sensor and 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eRecord Samples\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eup to 100 lots; 10.000 samples\/lot for automatic logging;  5000 samples\/lot for manual logging\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eLogging Interval\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003efrom one second and up\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eType\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003emanual. automatic\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGLP Features\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eyes (last calibration data. calibration info)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAlarm (DO. BOD. OUR. SOUR)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003einside and outside limits\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eopto-isolated USB and RS232\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003egraphic color LCD with on-screen help. graphing. language selection and custom configuration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e12 VDC adapter (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e160 x 231 x 94 mm (6.3 x 9.1 x 3.7”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.2 Kg (2.6 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":5832173893,"sku":"HI4421-02","price":2897.12,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/research-grade-sauerstoff-labormessgerat-482_1-1_2015.jpeg?v=1465536861"},{"product_id":"hi2040-02","title":"HANNA HI 2040-02 edge™ - Dissolved Oxygen (DO)  Meter","description":"\u003cdiv id=\"gt-res-content\" class=\"almost_half_cell\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cdiv id=\"gt-res-content\" class=\"almost_half_cell\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cp style=\"text-align: justify;\"\u003eHanna Instruments is proud to introduce the world’s most innovative pH. EC. and DO meter... edge™.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cbr\u003e edge is thin and lightweight. measuring just 1⁄2” thick and weighing less than 9 ounces. edge has an incredibly wide viewing angle. 5.5” LCD and a sensitive capacitive touch keypad.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cbr\u003e edge measures pH. conductivity and dissolved oxygen through its unique digital electrodes. These digital electrodes are auto-recognized. Providing sensor type. calibration data and serial number when connected to edge with an easy to plug-in 3.5mm connector. edge’s versatile design is equally at home in your hand. on a lab bench or mounted on a wall. It simplifies measurement. configuration. calibration. diagnostics. logging and transferring data to a computer or a USB drive.\u003cbr\u003e edge features Hanna’s exclusive CAL-CHECK® to warn you if the pH electrode you are using is not clean or if your buffers are contaminated during calibration. Indicators are also displayed for response time and probe condition that is based on the offset and slope of the electrode. We have also added to SENSOR-CHECK for sensors with matching pin: now it warns you if the pH bulb is cracked or if the junction of the electrode is clogged.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cbr\u003e edge is the culmination of Hanna’s vision. design capabilities. integrated production facilities. and world class R\u0026amp;D teams. With edge. Hanna has set the new standard!\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eFEATURES\u003c\/p\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eThin. Lightweight Design\u003c\/li\u003e\n\u003cli\u003eMultiparameter (ability to measure pH. EC or DO)\u003c\/li\u003e\n\u003cli\u003epH Electrode Monitoring Technology (Sensor Check and Cal Check)\u003c\/li\u003e\n\u003cli\u003eMultiple Calibration Points\u003c\/li\u003e\n\u003cli\u003eBuilt-in Temperature Sensor on all Electrodes\u003c\/li\u003e\n\u003cli\u003eLog on Demand\u003c\/li\u003e\n\u003cli\u003eLarge. easy to read LCD\u003c\/li\u003e\n\u003cli\u003eCapacitive Touch\u003c\/li\u003e\n\u003cli\u003eDual USB ports\u003c\/li\u003e\n\u003cli\u003eGLP feature\u003c\/li\u003e\n\u003cli\u003eRechargeable Battery      \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   edge HI2040-02 (230V) includes benchtop docking station with electrode holder. wall mount cradle. USB cable. HI 764080 Dissolved Oxygen electrode. HI 7041S Refill electrolyte solution. 2 DO membrane caps. 2 DO membrane cap o-rings. 5 VDC power adapter. and instruction manual.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Range\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 mg\/L (ppm) 0.0 to 300.0% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Resolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm) 0.1% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Accuracy @ 25°C\/77°F\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration Points\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 point slope calibration with probe in water saturated air (100%)   1 point offset calibration in HI 7040 solution (0%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic: 0.0 to 50.0°C; 32.0 to 122.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Salinity Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L (1 g\/L resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Altitude Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-500 to 4000m (100m resolution). -1640 to 13120’ (328’ resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range [°C\/°F]\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C; -4.0 to 248.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy @ 25°C\/77°F\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.5°C; ±1.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e°C\/°F\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyboard\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9 Keys (on\/off. 8 dedicated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Feature\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUp to 1000 records organized in Manual Log on demand  (Max. 200 logs). Manual log on Stability (Max. 200 logs). Interval logging with up to 100 lots (Max. 600 logs\/lot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Interface\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Interface\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMicro USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e202 x 140 x 12.7 mm (8” x 5.5” x .05”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e250 grams (8.82 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ewith temperature compensation function disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003etemperature limits will be reduced to actual probe\/sensor limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e***\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003epH 3.00 is only visible when using specific pH electrodes and will replace pH 4.01 buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":5832219589,"sku":"HI2040-02","price":1168.05,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/edge-electrode-beaker-in-cradle-01_2015_76ba44b3-68db-4b37-ab17-eef30e5b44bb.jpeg?v=1465536522"},{"product_id":"hi2020f","title":"HANNA HI2020F edge™ Fullpack - pH\/DO\/EC\/TDS\/NaCl\/°C Meter inkl. 3 Sonden","description":"\u003cdiv id=\"gt-res-content\" class=\"almost_half_cell\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cdiv id=\"gt-res-content\" class=\"almost_half_cell\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan id=\"result_box\" lang=\"de\"\u003e\u003cstrong\u003e\u003cspan class=\"hps\"\u003eHanna Instruments\u003c\/span\u003e\u003c\/strong\u003e \u003cspan class=\"hps\"\u003eist stolz darauf.\u003c\/span\u003e \u003cspan class=\"hps\"\u003eden \u003cstrong\u003eweltweit\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e \u003cspan class=\"hps\"\u003einnovativsten\u003c\/span\u003e \u003cspan class=\"hps\"\u003epH+EC+DO+°C-Meter\u003c\/span\u003e\u003c\/strong\u003e \u003cspan class=\"hps\"\u003evorzustellen: \u003cstrong\u003ee\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"hps\"\u003edge™\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan id=\"result_box\" lang=\"de\"\u003e\u003cstrong\u003e\u003cspan class=\"hps\"\u003eedge™\u003c\/span\u003e\u003c\/strong\u003e \u003cspan class=\"hps\"\u003eist dünn\u003c\/span\u003e \u003cspan class=\"hps\"\u003eund leicht. \u003cstrong\u003e\u003cspan class=\"hps\"\u003eedge™\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e \u003cspan class=\"hps\"\u003ehat einen unglaublich\u003c\/span\u003e \u003cspan class=\"hps\"\u003eweiten Betrachtungswinkel\u003c\/span\u003e\u003cspan\u003e. 5.5\u003c\/span\u003e \u003cspan class=\"hps\"\u003e\"LCD\u003c\/span\u003e \u003cspan class=\"hps\"\u003eund\u003c\/span\u003e \u003cspan class=\"hps\"\u003eein sensibles\u003c\/span\u003e \u003cspan class=\"hps\"\u003eTouch\u003c\/span\u003e\u003cspan class=\"hps\"\u003ekeypad.\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan id=\"result_box\" lang=\"de\"\u003e\u003cstrong\u003e\u003cspan class=\"hps\"\u003eedge™\u003c\/span\u003e\u003c\/strong\u003e \u003cspan class=\"hps\"\u003emisst \u003cstrong\u003epH\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e. Leitfähigkeit (EC). total gelösste Stoffe (TDS). Salzgehalt (NaCl) und \u003cspan class=\"hps\"\u003egelöster Sauerstoff\u003c\/span\u003e\u003c\/strong\u003e \u003cstrong\u003e(DO)\u003c\/strong\u003e \u003cspan class=\"hps\"\u003edurch seine einzigartigen\u003c\/span\u003e \u003cspan class=\"hps\"\u003edigitalen\u003c\/span\u003e \u003cspan class=\"hps\"\u003eElektroden\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan id=\"result_box\" lang=\"de\"\u003e\u003cspan class=\"hps\"\u003eDiese digitalen\u003c\/span\u003e \u003cspan class=\"hps\"\u003eElektroden\u003c\/span\u003e \u003cspan class=\"hps\"\u003ewerden automatisch\u003c\/span\u003e \u003cspan class=\"hps\"\u003eerkannt \u003c\/span\u003e\u003cspan class=\"hps\"\u003e (\u003c\/span\u003e\u003cspan class=\"hps\"\u003eSensor-Typ\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e \u003cspan class=\"hps\"\u003eKalibrierdaten\u003c\/span\u003e \u003cspan class=\"hps\"\u003eund die Seriennummer)\u003c\/span\u003e\u003cspan\u003e. verbunden\u003c\/span\u003e \u003cspan class=\"hps\"\u003emit einem\u003c\/span\u003e \u003cspan class=\"hps\"\u003eeasy Plug\u003c\/span\u003e\u003cspan class=\"atn\"\u003e-\u003c\/span\u003e\u003cspan\u003ein\u003c\/span\u003e \u003cspan class=\"hps\"\u003e3.5 mm\u003c\/span\u003e \u003cspan class=\"hps\"\u003eStecker\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan id=\"result_box\" lang=\"de\"\u003e\u003cstrong\u003e\u003cspan class=\"hps\"\u003eedge's \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"hps\"\u003esensatinelles\u003c\/span\u003e\u003cstrong\u003e\u003cspan class=\"hps\"\u003e \u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"hps\"\u003eDesign passt für\u003c\/span\u003e\u003cspan class=\"hps\"\u003e zu Hause. \u003c\/span\u003e\u003cspan class=\"hps\"\u003ein die Hand\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e \u003cspan class=\"hps\"\u003eauf einen\u003c\/span\u003e \u003cspan class=\"hps\"\u003eLabortisch\u003c\/span\u003e \u003cspan class=\"hps\"\u003eoder\u003c\/span\u003e \u003cspan class=\"hps\"\u003ean die Wand montiert\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan id=\"result_box\" lang=\"de\"\u003e\u003cspan class=\"hps\"\u003eedge™\u003c\/span\u003e \u003cspan class=\"hps\"\u003evereinfacht\u003c\/span\u003e \u003cspan class=\"hps\"\u003eMessung\u003c\/span\u003e\u003cspan\u003e.\u003c\/span\u003e \u003cspan class=\"hps\"\u003eKonfiguration. Kalibrierung\u003c\/span\u003e\u003cspan\u003e. Diagnose\u003c\/span\u003e\u003cspan\u003e. Protokollierung und\u003c\/span\u003e \u003cspan class=\"hps\"\u003eÜbertragung von Daten.\u003c\/span\u003e \u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan id=\"result_box\" lang=\"de\"\u003e\u003cspan class=\"hps\"\u003eedge™\u003c\/span\u003e \u003cspan class=\"hps\"\u003everfügt\u003c\/span\u003e über \u003cspan class=\"hps\"\u003eHanna's\u003c\/span\u003e \u003cspan class=\"hps\"\u003eexklusive\u003c\/span\u003e \u003cspan class=\"hps\"\u003eCAL\u003c\/span\u003e\u003cspan\u003e-CHECK\u003c\/span\u003e \u003cspan class=\"hps\"\u003e®\u003c\/span\u003e \u003cspan class=\"hps\"\u003eum Sie zu warnen\u003c\/span\u003e\u003cspan\u003e. wenn die Elektrode\u003c\/span\u003e \u003cspan class=\"hps\"\u003edie Sie verwenden\u003c\/span\u003e\u003cspan class=\"hps\"\u003e nicht sauber\u003c\/span\u003e ist \u003cspan class=\"hps\"\u003eoder wenn Ihr\u003c\/span\u003e \u003cspan class=\"hps\"\u003ePuffer\u003c\/span\u003e \u003cspan class=\"hps\"\u003ebei der Kalibrierung kontaminiert ist\u003c\/span\u003e\u003cspan class=\"hps\"\u003e. Bei Elektroden mit Matching Pin warn es sogar. wenn \u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan id=\"result_box\" lang=\"de\"\u003e\u003cspan class=\"hps\"\u003epH Membrane geknackt oder beschädigt ist.\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan lang=\"de\"\u003e\u003cspan class=\"hps\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan id=\"result_box\" lang=\"de\"\u003e\u003cspan class=\"hps\"\u003e\u003cstrong\u003e\u003cspan class=\"hps\"\u003eedge ™\u003c\/span\u003e\u003c\/strong\u003eist der \u003cstrong\u003eHöhepunkt von\u003c\/strong\u003e\u003c\/span\u003e\u003cstrong\u003e \u003cspan class=\"hps\"\u003eHanna\u003c\/span\u003e \u003cspan class=\"hps\"\u003eVision\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e.\u003c\/span\u003e \u003cspan class=\"hps\"\u003eDesign. Funktionalität.\u003c\/span\u003e \u003cspan class=\"hps\"\u003eintegrierten\u003c\/span\u003e \u003cspan class=\"hps\"\u003eFeatures \u003c\/span\u003e\u003cspan class=\"hps atn\"\u003eund Weltklasse \u003c\/span\u003e\u003cspan\u003eR\u003c\/span\u003e\u003cspan class=\"hps\"\u003e\u0026amp;\u003c\/span\u003e\u003cspan class=\"hps\"\u003eD \u003c\/span\u003e\u003cspan\u003eTeam.\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cspan id=\"result_box\" lang=\"en\"\u003e\u003cspan class=\"hps\"\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cspan lang=\"en\"\u003e\u003cspan class=\"hps\"\u003eFür weitere Details \u0026amp; Prospekt \u003ca href=\"http:\/\/hannainst.ch\/prospekt\/edge%20brochure.pdf\" data-mce-href=\"http:\/\/hannainst.ch\/prospekt\/edge%20brochure.pdf\"\u003e\u003cspan style=\"color: rgb(255. 0. 0);\" data-mce-style=\"color: #ff0000;\"\u003ehier\u003c\/span\u003e\u003c\/a\u003e klicken.\u003c\/span\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003eFür Video \u003ca href=\"http:\/\/hannainst.ch\/movie\/edge.mp4\" data-mce-href=\"http:\/\/hannainst.ch\/movie\/edge.mp4\"\u003e\u003cspan style=\"color: rgb(255. 0. 0);\" data-mce-style=\"color: #ff0000;\"\u003ehier\u003c\/span\u003e\u003c\/a\u003e klicken.\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cstrong\u003eHI2020F edge™ Fullpack - pH\/DO\/EC\/TDS\/NaCl\/°C Set\u003c\/strong\u003e: Automatische Temperatur-Kompensation. Messbereich EC 0.00?S\/cm bis 500mS\/cm - TDS 0.00mg\/L bis 400g\/L - Salzgehalt 0.0 bis 400.0% NaCl oder 0.0 bos 80.0g\/L; pH 0.000 bis 16.000. Genauigkeit 0.001pH. bis zu 7 Kalibriebpunkten; Messbereich 0.00 bis 45.00ppm \/ 0.0 bis 300.0% Sättigung. Salz-Kompensation. Höhen-Kompensation.\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cstrong\u003eLieferung komplett\u003c\/strong\u003e mit \u003cstrong\u003eHI763100\u003c\/strong\u003e \u003cstrong\u003edigitale Leitfähigkeitselektrode\u003c\/strong\u003e (4ring. Platin). \u003cstrong\u003epH Elektrode HI11310\u003c\/strong\u003e Glas. \u003cstrong\u003eHI764080 polarographische Sauerstoff-Sonde\u003c\/strong\u003e. Ständer. Elektrodenhalter und Bedienungsanleitung. \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":5832220101,"sku":"HI2020F","price":1399.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/edge-with-screen-vertical-01_2015_2b07ba7a-0c12-4cdb-bc75-3066d22b1fb3.jpeg?v=1443495635"},{"product_id":"tps-wp91-waterproof-dissolved-oxygen-ph-mv-meter-with-1m-cable-ysi-ph-sensors","title":"TPS WP91 Waterproof Dissolved Oxygen-pH-mV Meter with 1m cable, YSI \u0026 pH sensors","description":"\u003ch3 class=\"subtitle\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"two-columns\"\u003e\n\u003cp\u003e\u003cstrong\u003eppM (mg\/L)\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRanges* :\u003c\/strong\u003e \u003cbr\u003e0.0 to 20.00 ppM and 20.0 to 40.0 ppM\u003cbr\u003e\u003cstrong\u003eResolution :\u003c\/strong\u003e 0.01 \u0026amp; 0.1 ppM\u003cbr\u003e\u003cstrong\u003eAccuracy :\u003c\/strong\u003e +\/-0.2% of full scale of selected range\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e% Saturation\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRanges* :\u003c\/strong\u003e 0 to 240.0 %Sat'n and 240 to 450 %Sat'n\u003cbr\u003e\u003cstrong\u003eResolution :\u003c\/strong\u003e 0.1 \u0026amp; 1 %Sat'n\u003cbr\u003e\u003cstrong\u003eAccuracy :\u003c\/strong\u003e +\/-0.3 %Sat'n\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e% Gaseous\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRanges* :\u003c\/strong\u003e 0 to 45.0 %Gas and 45 to 100 %Gas\u003cbr\u003e\u003cstrong\u003eResolution :\u003c\/strong\u003e 0.1 \u0026amp; 1 %Gas\u003cbr\u003e\u003cstrong\u003eAccuracy :\u003c\/strong\u003e +\/-0.1 %Gas\u003cbr\u003e\u003cbr\u003e*Automatic range selection, subject to sensor performance. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRange :\u003c\/strong\u003e 0 to 14.00 pH\u003cbr\u003e\u003cstrong\u003eResolution :\u003c\/strong\u003e 0.01 pH\u003cbr\u003e\u003cstrong\u003eAccuracy :\u003c\/strong\u003e +\/-0.01pH\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003emV\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRange :\u003c\/strong\u003e\u003cbr\u003e0 to +\/-500.0 \u0026amp; 0 to +\/-1500 mV (auto-ranging)\u003cbr\u003e\u003cstrong\u003eResolution : \u003c\/strong\u003e0.15 and 1 mV\u003cbr\u003e\u003cstrong\u003eAccuracy :\u003c\/strong\u003e +\/-0.3 \u0026amp; +\/-1 mV\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eRange :\u003c\/strong\u003e -10.0 to 120.0 \u003csup\u003eo\u003c\/sup\u003eC (sensor limit 45 \u003csup\u003eo\u003c\/sup\u003eC)\u003cbr\u003e\u003cstrong\u003eResolution :\u003c\/strong\u003e 0.1 \u003csup\u003eo\u003c\/sup\u003eC\u003cbr\u003e\u003cstrong\u003eAccuracy :\u003c\/strong\u003e +\/-0.2 \u003csup\u003eo\u003c\/sup\u003eC\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSalinity Correction\u003c\/strong\u003e\u003cbr\u003eUser-set, from 0 to 50.0 ppK NaCl\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBarometric Pressure Correction\u003c\/strong\u003e\u003cbr\u003eUser-set, from 800 to 1100 HPa\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAltitude Correction\u003c\/strong\u003e\u003cbr\u003eUser-set, from 0 to 5000m\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003epH Asymmetry Range\u003c\/strong\u003e\u003cbr\u003e-1.00 to +1.00 pH\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003epH Slope Range\u003c\/strong\u003e\u003cbr\u003e70.0 to 110.0 %\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAutomatic Buffer Recognition\u003c\/strong\u003e\u003cbr\u003e4.01, 6.86, 7.00, 9.18 \u0026amp; 10.01\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003cbr\u003e0 to 100 \u003csup\u003eo\u003c\/sup\u003eC, automatic or manual\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"two-columns\"\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosure\u003c\/strong\u003e\u003cbr\u003eTough, anti-static Luran-S plastic case, waterproof to IP67. Connectors waterproof to IP65. The instrument will float if dropped into water.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003cbr\u003e32 Character alphanumeric LCD with user-friendly menu system and full-text messages. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003cbr\u003e2400 readings, including date and time.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAutomatic Logging\u003c\/strong\u003e\u003cbr\u003eUser-set for one reading every 1 to 90 seconds, 1 to 90 minutes or 1 to 24 hours. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eRS232 Serial Port Output\u003c\/strong\u003e\u003cbr\u003e300, 1200 and 9600 Baud.\u003cbr\u003e8 Bits, No Parity, 1 Stop Bit, XON\/XOFF\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eClock\u003c\/strong\u003e\u003cbr\u003e24 Hour Calendar Clock\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBattery Saver Function\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eOn :\u003c\/strong\u003e Automatically switches off after 5 minutes of no use. \u003cbr\u003e\u003cstrong\u003eOff :\u003c\/strong\u003e Unit remains on for continuous use. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eGood Laboratory Practices\u003c\/strong\u003e\u003cbr\u003eDate, time and results of last successful calibration are stored, and can be recalled when required. GLP information can be printed or downloaded to PC when the optional RS232 Interface is fitted. Warning of failed calibration is provided. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003cbr\u003e6V NiMH Rechargeable battery pack for approx 75 hours operation. Battery charger for country of choice supplied. Battery can be charged from any 12V DC source.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003cbr\u003e187 x 110 x 51 mm\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eMass\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eInstrument only :\u003c\/strong\u003e Approx 440g\u003cbr\u003e\u003cstrong\u003eFull Kit :\u003c\/strong\u003e Approx 1.7kg\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eTemperature :\u003c\/strong\u003e 0 to 45 \u003csup\u003eo\u003c\/sup\u003eC\u003cbr\u003e\u003cstrong\u003eHumidity :\u003c\/strong\u003e 0 to 95% R.H.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3 class=\"subtitle\"\u003e\u003c\/h3\u003e","brand":"TPS","offers":[{"title":"Default Title","offer_id":38328379152,"sku":"123150\/1","price":2126.0,"currency_code":"NZD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/WP91.jpg?v=1559010737"}],"url":"https:\/\/acornsci.co.nz\/collections\/electrochemical-dissolved-oxygen\/type_conductivity-tds-meter.oembed","provider":"Acorn Scientific","version":"1.0","type":"link"}