{"id":1582192005,"title":"HANNA HI 1005 Flow-thru Monitoring pH Electrode with DIN Connection and 0.5 m Cable","handle":"hi-1005","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\" style=\"width: 475px; clear: left; color: #222222; font-family: Tahoma. Arial. FreeSans. Helvetica. sans-serif; font-size: 12px; line-height: 18px; background-color: #f2f3f3;\"\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003eFlow-thru monitoring pH electrode with DIN connection and 0.5 m cable.\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003e\u003cbig\u003eSpecifically Built for Industrial Applications\u003c\/big\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003e \u003c\/p\u003e\n\u003cul style=\"margin: 0px 0px 0px 20px;\"\u003e\n\u003cli\u003e½\" NPT external thread for in-line installation\u003c\/li\u003e\n\u003cli\u003epH electrode with exclusive PTFE non-clogging membrane\u003c\/li\u003e\n\u003cli\u003eDouble-junction technology\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003eModels with built-in matching pin and amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003eIn order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003eBoth pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003eHI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH\/ORP meter quick and easy; models with 3 or 5 meters (9.8 or 16 feet) cable are available.\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\" style=\"margin: 0px; padding: 0px; float: left; clear: none; width: 456.9375px; color: #222222; font-family: Tahoma. Arial. FreeSans. Helvetica. sans-serif; font-size: 12px; line-height: 18px; background-color: #f2f3f3;\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\" style=\"margin: 0px 0px 0px 20px; padding: 0px;\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\" style=\"position: relative; top: 1px; float: left; padding: 2px 4px; margin: 0px 1px 0px 0px; font-weight: bold; line-height: normal; font-family: sans-serif; background-color: #eeeeee; list-style: none; border-style: solid; border-width: 1px; border-color: #999999 #999999 #eeeeee #cccccc; cursor: pointer; font-size: 11px;\"\u003eSpecifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\" style=\"clear: both; border-style: solid; border-width: 1px; border-color: #999999 #999999 #cccccc #cccccc; background-color: #eeeeee;\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\" style=\"padding: 4px;\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edouble. PTFE\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003epolymer\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5 to 80°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e6 bar (87 psi)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eBNC\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e3 m\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T15:52:59+12:00","created_at":"2015-09-01T15:19:35+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Electrodes \u0026 Probes"],"price":25840,"price_min":25840,"price_max":25840,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857340741,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI1005","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 1005 Flow-thru Monitoring pH Electrode with DIN Connection and 0.5 m Cable","public_title":null,"options":["Default Title"],"price":25840,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/HI1005_200_2015.jpeg?v=1465536299"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI1005_200_2015.jpeg?v=1465536299","options":["Title"],"media":[{"alt":"HI 1005 Flow-thru Monitoring pH Electrode with DIN Connection and 0.5 m Cable - Acorn Scientific","id":21310603363,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI1005_200_2015.jpeg?v=1465536299"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI1005_200_2015.jpeg?v=1465536299","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\" style=\"width: 475px; clear: left; color: #222222; font-family: Tahoma. Arial. FreeSans. Helvetica. sans-serif; font-size: 12px; line-height: 18px; background-color: #f2f3f3;\"\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003eFlow-thru monitoring pH electrode with DIN connection and 0.5 m cable.\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003e\u003cbig\u003eSpecifically Built for Industrial Applications\u003c\/big\u003e\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003e \u003c\/p\u003e\n\u003cul style=\"margin: 0px 0px 0px 20px;\"\u003e\n\u003cli\u003e½\" NPT external thread for in-line installation\u003c\/li\u003e\n\u003cli\u003epH electrode with exclusive PTFE non-clogging membrane\u003c\/li\u003e\n\u003cli\u003eDouble-junction technology\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003eModels with built-in matching pin and amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003e \u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003eIn order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003eBoth pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003eHI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH\/ORP meter quick and easy; models with 3 or 5 meters (9.8 or 16 feet) cable are available.\u003c\/p\u003e\n\u003cp style=\"margin: 0px 0px 15px;\"\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\" style=\"margin: 0px; padding: 0px; float: left; clear: none; width: 456.9375px; color: #222222; font-family: Tahoma. Arial. FreeSans. Helvetica. sans-serif; font-size: 12px; line-height: 18px; background-color: #f2f3f3;\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\" style=\"margin: 0px 0px 0px 20px; padding: 0px;\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\" style=\"position: relative; top: 1px; float: left; padding: 2px 4px; margin: 0px 1px 0px 0px; font-weight: bold; line-height: normal; font-family: sans-serif; background-color: #eeeeee; list-style: none; border-style: solid; border-width: 1px; border-color: #999999 #999999 #eeeeee #cccccc; cursor: pointer; font-size: 11px;\"\u003eSpecifications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\" style=\"clear: both; border-style: solid; border-width: 1px; border-color: #999999 #999999 #cccccc #cccccc; background-color: #eeeeee;\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\" style=\"padding: 4px;\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edouble. PTFE\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003epolymer\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-5 to 80°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e6 bar (87 psi)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eBNC\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e3 m\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 1005 Flow-thru Monitoring pH Electrode with DIN Connection and 0.5 m Cable

Product Description

 

Flow-thru monitoring pH electrode with DIN connection and 0.5 m cable.

 

Specifically Built for Industrial Applications

 

  • ½" NPT external thread for in-line installation
  • pH electrode with exclusive PTFE non-clogging membrane
  • Double-junction technology
  • PVDF body
  • Models with built-in matching pin and amplifier

 

In order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).

Both pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.

HI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH/ORP meter quick and easy; models with 3 or 5 meters (9.8 or 16 feet) cable are available.

 

  • Specifications
Junction   double. PTFE
Electrolyte   polymer
Temperature   -5 to 80°C
Max Pressure   6 bar (87 psi)
Connection   BNC
Cable   3 m