{"id":2012186821,"title":"Hanna HI 1005 - pH Electrode. Flow-thru Monitoring for PCA","handle":"hi1005","description":"\u003cp\u003eFlow-thru monitoring pH electrode with DIN connection and 0.5 m cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e ½\" NPT external thread for in-line installation\u003c\/li\u003e\n\u003cli\u003epH electrode with exclusive PTFE non-clogging membrane\u003c\/li\u003e\n\u003cli\u003eDouble-junction technology\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003eModels with built-in matching pin and amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).\u003c\/p\u003e\n\u003cp\u003eBoth pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.\u003c\/p\u003e\n\u003cp\u003eHI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH\/ORP meter quick and easy.\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003edouble. PTFE\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epolymer\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e-5 to 80°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e6 bar (87 psi)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eBNC\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e3 m\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2016-07-12T14:27:00+12:00","created_at":"2015-09-04T15:21:03+12:00","vendor":"HANNA Instruments Inc.","type":"Electrochemical","tags":["brand_Hanna","Category_Clearance","Category_pH","Type_Probe"],"price":17100,"price_min":17100,"price_max":17100,"available":true,"price_varies":false,"compare_at_price":37200,"compare_at_price_min":37200,"compare_at_price_max":37200,"compare_at_price_varies":false,"variants":[{"id":5764411717,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI1005","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"Hanna HI 1005 - pH Electrode. Flow-thru Monitoring for PCA","public_title":null,"options":["Default Title"],"price":17100,"weight":0,"compare_at_price":37200,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":""}],"images":["\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi1005_400-1_2015.jpeg?v=1465536295","\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e58d2a3d462_2015.jpeg?v=1465536296"],"featured_image":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/products\/hi1005_400-1_2015.jpeg?v=1465536295","options":["Title"],"content":"\u003cp\u003eFlow-thru monitoring pH electrode with DIN connection and 0.5 m cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e ½\" NPT external thread for in-line installation\u003c\/li\u003e\n\u003cli\u003epH electrode with exclusive PTFE non-clogging membrane\u003c\/li\u003e\n\u003cli\u003eDouble-junction technology\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003eModels with built-in matching pin and amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).\u003c\/p\u003e\n\u003cp\u003eBoth pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.\u003c\/p\u003e\n\u003cp\u003eHI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH\/ORP meter quick and easy.\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003edouble. PTFE\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epolymer\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e-5 to 80°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e6 bar (87 psi)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eBNC\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e3 m\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}
Hanna HI 1005 - pH Electrode. Flow-thru Monitoring for PCA
Related Products
Hanna BL5-2 Black Stone Dosing Pump 5.0 lph 7 bar
$176.00 $382.00
Hanna BL983320-1 Conductivity Mini Controller @ 199.9 µS/cm
$202.00 $438.00
Hanna Dissolved Oxygen probe electrolyte solution 250mL
$54.00 $117.00
Hanna FC098 Blade attachment for Electrode - 20mm
$192.00 $417.00
Hanna FC099 Blade attachment for Electrode - 35mm
$186.00 $403.00
Hanna FC100B Foodcare pH Electrode for Cheese BNC Connection
$169.00 $367.00