{"id":2031646341,"title":"HI 2020-02 edge™ - pH Meter","handle":"hi2020-02","description":"\u003cdiv id=\"gt-res-content\" class=\"almost_half_cell\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cdiv id=\"gt-res-content\" class=\"almost_half_cell\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cp style=\"text-align: justify;\"\u003eHanna Instruments is proud to introduce the world’s most innovative pH. EC. and DO meter... edge™.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eedge is thin and lightweight. measuring just 1⁄2” thick and weighing less than 9 ounces. edge has an incredibly wide viewing angle. 5.5” LCD and a sensitive capacitive touch keypad.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eedge measures pH. conductivity and dissolved oxygen through its unique digital electrodes. These digital electrodes are auto-recognized. Providing sensor type. calibration data and serial number when connected to edge with an easy to plug-in 3.5mm connector. edge’s versatile design is equally at home in your hand. on a lab bench or mounted on a wall. It simplifies measurement. configuration. calibration. diagnostics. logging and transferring data to a computer or a USB drive.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cbr\u003e edge features Hanna’s exclusive CAL-CHECK® to warn you if the pH electrode you are using is not clean or if your buffers are contaminated during calibration. Indicators are also displayed for response time and probe condition that is based on the offset and slope of the electrode. We have also added to SENSOR-CHECK for sensors with matching pin: now it warns you if the pH bulb is cracked or if the junction of the electrode is clogged.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cbr\u003e edge is the culmination of Hanna’s vision. design capabilities. integrated production facilities. and world class R\u0026amp;D teams. With edge. Hanna has set the new standard!\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eFEATURES:\u003c\/p\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eThin. Lightweight Design\u003c\/li\u003e\n\u003cli\u003eMultiparameter (ability to measure pH. EC or DO)\u003c\/li\u003e\n\u003cli\u003epH Electrode Monitoring Technology (Sensor Check and Cal Check)\u003c\/li\u003e\n\u003cli\u003eMultiple Calibration Points\u003c\/li\u003e\n\u003cli\u003eBuilt-in Temperature Sensor on all Electrodes\u003c\/li\u003e\n\u003cli\u003eLog on Demand\u003c\/li\u003e\n\u003cli\u003eLarge. easy to read LCD\u003c\/li\u003e\n\u003cli\u003eCapacitive Touch\u003c\/li\u003e\n\u003cli\u003eDual USB ports\u003c\/li\u003e\n\u003cli\u003eGLP feature\u003c\/li\u003e\n\u003cli\u003eRechargeable Battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   edge HI2020-02 (230V) includes benchtop docking station with electrode holder. wall mount cradle. USB cable. HI11310 glass body refillable pH electrode with temperature sensor. 2 each sachets of pH 4. 7. 10. cleaning and storage solution. 5 VDC power adapter. and instruction manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH (Basic Mode) -2.000 to 16.000 pH (Standard Mode) +\/-1000.0 mV for pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 pH. 0.001 pH 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy @ 25°C\/77°F\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.01 pH. ±0.002 pH ±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Points\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 – Extended mode 3 – Basic mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic: -20.0 to 120.0°C; -4.0 to 248.0°F**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Condition\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES– Standard mode (pH only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Response\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES– Standard mode (pH only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOut of Calibration Range\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES– Standard mode (pH only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Buffers\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.68. 4.01 (3.00***). 6.86. 7.01. 9.18. 10.01. 12.45. and two custom buffers – Standard mode 4.01; 6.86; 7.01; 9.18; 10.01 - Basic mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range [°C\/°F]\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C; -4.0 to 248.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy @ 25°C\/77°F\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.5°C; ±1.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e°C\/°F\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyboard\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9 Keys (on\/off. 8 dedicated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Feature\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUp to 1000 records organized in Manual Log on demand  (Max. 200 logs). Manual log on Stability (Max. 200 logs). Interval logging with up to 100 lots (Max. 600 logs\/lot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Interface\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Interface\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMicro USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e202 x 140 x 12.7 mm (8” x 5.5” x .05”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e250 grams (8.82 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ewith temperature compensation function disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003etemperature limits will be reduced to actual probe\/sensor limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e***\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003epH 3.00 is only visible when using specific pH electrodes and will replace pH 4.01 buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2016-12-14T09:56:00+13:00","created_at":"2015-09-07T15:18:06+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["brand_Hanna","Manufacturer_Hanna Instruments","Type_pH \u0026 ORP Meters"],"price":78900,"price_min":78900,"price_max":78900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5832219269,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI2020-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HI 2020-02 edge™ - pH Meter","public_title":null,"options":["Default Title"],"price":78900,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/edge-electrode-beaker-in-cradle-01_2015.jpeg?v=1465536518","\/\/acornsci.co.nz\/cdn\/shop\/products\/edge-usb-ports-01_2015.jpeg?v=1465536519","\/\/acornsci.co.nz\/cdn\/shop\/products\/edge-with-screen-vertical-01_2015.jpeg?v=1465536519"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/edge-electrode-beaker-in-cradle-01_2015.jpeg?v=1465536518","options":["Title"],"media":[{"alt":"HI 2020-02 edge™ - pH Meter - Acorn Scientific","id":25254723683,"position":1,"preview_image":{"aspect_ratio":1.0,"height":648,"width":648,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/edge-electrode-beaker-in-cradle-01_2015.jpeg?v=1465536518"},"aspect_ratio":1.0,"height":648,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/edge-electrode-beaker-in-cradle-01_2015.jpeg?v=1465536518","width":648},{"alt":"HI 2020-02 edge™ - pH Meter - Acorn Scientific","id":25254756451,"position":2,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/edge-usb-ports-01_2015.jpeg?v=1465536519"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/edge-usb-ports-01_2015.jpeg?v=1465536519","width":800},{"alt":"HI 2020-02 edge™ - pH Meter - Acorn Scientific","id":25254789219,"position":3,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/edge-with-screen-vertical-01_2015.jpeg?v=1465536519"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/edge-with-screen-vertical-01_2015.jpeg?v=1465536519","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv id=\"gt-res-content\" class=\"almost_half_cell\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cdiv id=\"gt-res-content\" class=\"almost_half_cell\"\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003cp style=\"text-align: justify;\"\u003eHanna Instruments is proud to introduce the world’s most innovative pH. EC. and DO meter... edge™.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eedge is thin and lightweight. measuring just 1⁄2” thick and weighing less than 9 ounces. edge has an incredibly wide viewing angle. 5.5” LCD and a sensitive capacitive touch keypad.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eedge measures pH. conductivity and dissolved oxygen through its unique digital electrodes. These digital electrodes are auto-recognized. Providing sensor type. calibration data and serial number when connected to edge with an easy to plug-in 3.5mm connector. edge’s versatile design is equally at home in your hand. on a lab bench or mounted on a wall. It simplifies measurement. configuration. calibration. diagnostics. logging and transferring data to a computer or a USB drive.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cbr\u003e edge features Hanna’s exclusive CAL-CHECK® to warn you if the pH electrode you are using is not clean or if your buffers are contaminated during calibration. Indicators are also displayed for response time and probe condition that is based on the offset and slope of the electrode. We have also added to SENSOR-CHECK for sensors with matching pin: now it warns you if the pH bulb is cracked or if the junction of the electrode is clogged.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cbr\u003e edge is the culmination of Hanna’s vision. design capabilities. integrated production facilities. and world class R\u0026amp;D teams. With edge. Hanna has set the new standard!\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eFEATURES:\u003c\/p\u003e\n\u003cul style=\"text-align: justify;\"\u003e\n\u003cli\u003eThin. Lightweight Design\u003c\/li\u003e\n\u003cli\u003eMultiparameter (ability to measure pH. EC or DO)\u003c\/li\u003e\n\u003cli\u003epH Electrode Monitoring Technology (Sensor Check and Cal Check)\u003c\/li\u003e\n\u003cli\u003eMultiple Calibration Points\u003c\/li\u003e\n\u003cli\u003eBuilt-in Temperature Sensor on all Electrodes\u003c\/li\u003e\n\u003cli\u003eLog on Demand\u003c\/li\u003e\n\u003cli\u003eLarge. easy to read LCD\u003c\/li\u003e\n\u003cli\u003eCapacitive Touch\u003c\/li\u003e\n\u003cli\u003eDual USB ports\u003c\/li\u003e\n\u003cli\u003eGLP feature\u003c\/li\u003e\n\u003cli\u003eRechargeable Battery\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   edge HI2020-02 (230V) includes benchtop docking station with electrode holder. wall mount cradle. USB cable. HI11310 glass body refillable pH electrode with temperature sensor. 2 each sachets of pH 4. 7. 10. cleaning and storage solution. 5 VDC power adapter. and instruction manual.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH (Basic Mode) -2.000 to 16.000 pH (Standard Mode) +\/-1000.0 mV for pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 pH. 0.001 pH 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy @ 25°C\/77°F\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.01 pH. ±0.002 pH ±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Points\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 – Extended mode 3 – Basic mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic: -20.0 to 120.0°C; -4.0 to 248.0°F**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Condition\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES– Standard mode (pH only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Response\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES– Standard mode (pH only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOut of Calibration Range\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES– Standard mode (pH only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Buffers\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.68. 4.01 (3.00***). 6.86. 7.01. 9.18. 10.01. 12.45. and two custom buffers – Standard mode 4.01; 6.86; 7.01; 9.18; 10.01 - Basic mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range [°C\/°F]\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C; -4.0 to 248.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy @ 25°C\/77°F\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.5°C; ±1.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e°C\/°F\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eYES\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyboard\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9 Keys (on\/off. 8 dedicated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLog Feature\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUp to 1000 records organized in Manual Log on demand  (Max. 200 logs). Manual log on Stability (Max. 200 logs). Interval logging with up to 100 lots (Max. 600 logs\/lot)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Interface\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Interface\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eMicro USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e202 x 140 x 12.7 mm (8” x 5.5” x .05”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e250 grams (8.82 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ewith temperature compensation function disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e**\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003etemperature limits will be reduced to actual probe\/sensor limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e***\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003epH 3.00 is only visible when using specific pH electrodes and will replace pH 4.01 buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HI 2020-02 edge™ - pH Meter

Product Description

Hanna Instruments is proud to introduce the world’s most innovative pH. EC. and DO meter... edge™.

edge is thin and lightweight. measuring just 1⁄2” thick and weighing less than 9 ounces. edge has an incredibly wide viewing angle. 5.5” LCD and a sensitive capacitive touch keypad.

edge measures pH. conductivity and dissolved oxygen through its unique digital electrodes. These digital electrodes are auto-recognized. Providing sensor type. calibration data and serial number when connected to edge with an easy to plug-in 3.5mm connector. edge’s versatile design is equally at home in your hand. on a lab bench or mounted on a wall. It simplifies measurement. configuration. calibration. diagnostics. logging and transferring data to a computer or a USB drive.


edge features Hanna’s exclusive CAL-CHECK® to warn you if the pH electrode you are using is not clean or if your buffers are contaminated during calibration. Indicators are also displayed for response time and probe condition that is based on the offset and slope of the electrode. We have also added to SENSOR-CHECK for sensors with matching pin: now it warns you if the pH bulb is cracked or if the junction of the electrode is clogged.


edge is the culmination of Hanna’s vision. design capabilities. integrated production facilities. and world class R&D teams. With edge. Hanna has set the new standard!

FEATURES:

  • Thin. Lightweight Design
  • Multiparameter (ability to measure pH. EC or DO)
  • pH Electrode Monitoring Technology (Sensor Check and Cal Check)
  • Multiple Calibration Points
  • Built-in Temperature Sensor on all Electrodes
  • Log on Demand
  • Large. easy to read LCD
  • Capacitive Touch
  • Dual USB ports
  • GLP feature
  • Rechargeable Battery

 

 

Order Information:   edge HI2020-02 (230V) includes benchtop docking station with electrode holder. wall mount cradle. USB cable. HI11310 glass body refillable pH electrode with temperature sensor. 2 each sachets of pH 4. 7. 10. cleaning and storage solution. 5 VDC power adapter. and instruction manual.

Specification :
pH Range   -2.00 to 16.00 pH (Basic Mode) -2.000 to 16.000 pH (Standard Mode) +/-1000.0 mV for pH
pH Resolution   0.01 pH. 0.001 pH 0.1 mV
pH Accuracy @ 25°C/77°F   ±0.01 pH. ±0.002 pH ±0.2 mV
pH Calibration Points   5 – Extended mode 3 – Basic mode
pH Temperature Compensation   Automatic: -20.0 to 120.0°C; -4.0 to 248.0°F**
Electrode Condition   YES– Standard mode (pH only)
Electrode Response   YES– Standard mode (pH only)
Out of Calibration Range   YES– Standard mode (pH only)
pH Buffers   1.68. 4.01 (3.00***). 6.86. 7.01. 9.18. 10.01. 12.45. and two custom buffers – Standard mode 4.01; 6.86; 7.01; 9.18; 10.01 - Basic mode
Temperature Range [°C/°F]   -20.0 to 120.0°C; -4.0 to 248.0°F
Temperature Resolution   0.1°C; 0.1°F
Temperature Accuracy @ 25°C/77°F   ±0.5°C; ±1.0°F
°C/°F   YES
GLP   YES
Keyboard   9 Keys (on/off. 8 dedicated)
Log Feature   Up to 1000 records organized in Manual Log on demand  (Max. 200 logs). Manual log on Stability (Max. 200 logs). Interval logging with up to 100 lots (Max. 600 logs/lot)
Storage Interface   USB
PC Interface   Micro USB
Power Supply   5 VDC
Dimensions   202 x 140 x 12.7 mm (8” x 5.5” x .05”)
Weight   250 grams (8.82 oz.)
*   with temperature compensation function disabled
**   temperature limits will be reduced to actual probe/sensor limits
***   pH 3.00 is only visible when using specific pH electrodes and will replace pH 4.01 buffer