{"id":1582177413,"title":"HANNA HI983304-02 Conductivity Meter for Demineralized Water","handle":"hi-983304-02","description":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifically designed for demineralization and deionization applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan id=\"x5nq93_2\" class=\"x5nq93\"\u003eWater resistant\u003c\/span\u003e enclosure\u003c\/li\u003e\n\u003cli\u003eExternal 12 VDC power supply for continuous monitoring\u003c\/li\u003e\n\u003cli\u003eSelectable setpoint and LED alarm\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eMolded hook for easy installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 983304-01 is specifically designed for use in demineralized and \u003cspan id=\"x5nq93_1\" class=\"x5nq93\"\u003edeionized water\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eWhen placed at the output of any demineralization system. the visual alarm will be activated once the demineralizing equipment is exhausted. This exclusive feature will ensure maximum system efficiency with minimum investment. \u003c\/p\u003e\n\u003cp\u003eThis meter is supplied with an HI 7631\/2 direct 2-pin probe with 2 m (6.6') cable and a ½\" thread for flow-thru mounting. This probe is also equipped with a \u003cspan id=\"x5nq93_3\" class=\"x5nq93\"\u003etemperature sensor\u003c\/span\u003e to automatically compensate measurements against temperature changes from 5 to 50°C (41 to 122°F).\u003c\/p\u003e\n\u003cp\u003eWhen operating in the measurement mode. HI 983304-01’s red LED will alert the user as soon as the reading is 1 µS\/cm over the setpoint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 983304-01 (115V) and HI 983304-02 (230V) are supplied with HI 7631\/2 EC\/TDS probe. calibration screwdriver. 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 19.99 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. 1 point through trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 5 to 50°C (41 to 122°F) with ß=2.4%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.00 to 5.00 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ered LED (blinks when measurement differs from setpoint by:\u003cbr\u003e±1.00 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7631\/2 with 2 m (6.6') cable and ½\" thread\u003cbr\u003e(included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 Vdc power adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e86 x 110 x 43 mm (3.4 x 4.3 x 1.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e215 g (7.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2017-11-23T09:19:58+13:00","created_at":"2015-09-01T15:17:14+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments"],"price":26000,"price_min":26000,"price_max":26000,"available":true,"price_varies":false,"compare_at_price":26000,"compare_at_price_min":26000,"compare_at_price_max":26000,"compare_at_price_varies":false,"variants":[{"id":4857316165,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI 983304-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI983304-02 Conductivity Meter for Demineralized Water","public_title":null,"options":["Default Title"],"price":26000,"weight":0,"compare_at_price":26000,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/983304_01_200-1_2015.jpeg?v=1443495762"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/983304_01_200-1_2015.jpeg?v=1443495762","options":["Title"],"media":[{"alt":null,"id":21304246371,"position":1,"preview_image":{"aspect_ratio":0.98,"height":200,"width":196,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/983304_01_200-1_2015.jpeg?v=1443495762"},"aspect_ratio":0.98,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/983304_01_200-1_2015.jpeg?v=1443495762","width":196}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eSpecifically designed for demineralization and deionization applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan id=\"x5nq93_2\" class=\"x5nq93\"\u003eWater resistant\u003c\/span\u003e enclosure\u003c\/li\u003e\n\u003cli\u003eExternal 12 VDC power supply for continuous monitoring\u003c\/li\u003e\n\u003cli\u003eSelectable setpoint and LED alarm\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eMolded hook for easy installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHI 983304-01 is specifically designed for use in demineralized and \u003cspan id=\"x5nq93_1\" class=\"x5nq93\"\u003edeionized water\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003eWhen placed at the output of any demineralization system. the visual alarm will be activated once the demineralizing equipment is exhausted. This exclusive feature will ensure maximum system efficiency with minimum investment. \u003c\/p\u003e\n\u003cp\u003eThis meter is supplied with an HI 7631\/2 direct 2-pin probe with 2 m (6.6') cable and a ½\" thread for flow-thru mounting. This probe is also equipped with a \u003cspan id=\"x5nq93_3\" class=\"x5nq93\"\u003etemperature sensor\u003c\/span\u003e to automatically compensate measurements against temperature changes from 5 to 50°C (41 to 122°F).\u003c\/p\u003e\n\u003cp\u003eWhen operating in the measurement mode. HI 983304-01’s red LED will alert the user as soon as the reading is 1 µS\/cm over the setpoint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 983304-01 (115V) and HI 983304-02 (230V) are supplied with HI 7631\/2 EC\/TDS probe. calibration screwdriver. 12 VDC adapter and instructions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 19.99 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003emanual. 1 point through trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. 5 to 50°C (41 to 122°F) with ß=2.4%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.00 to 5.00 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ered LED (blinks when measurement differs from setpoint by:\u003cbr\u003e±1.00 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Probe\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eHI 7631\/2 with 2 m (6.6') cable and ½\" thread\u003cbr\u003e(included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e12 Vdc power adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e86 x 110 x 43 mm (3.4 x 4.3 x 1.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e215 g (7.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI983304-02 Conductivity Meter for Demineralized Water

Product Description
  • Specifically designed for demineralization and deionization applications
  • Water resistant enclosure
  • External 12 VDC power supply for continuous monitoring
  • Selectable setpoint and LED alarm
  • Automatic Temperature Compensation
  • Molded hook for easy installation

 

HI 983304-01 is specifically designed for use in demineralized and deionized water.

When placed at the output of any demineralization system. the visual alarm will be activated once the demineralizing equipment is exhausted. This exclusive feature will ensure maximum system efficiency with minimum investment. 

This meter is supplied with an HI 7631/2 direct 2-pin probe with 2 m (6.6') cable and a ½" thread for flow-thru mounting. This probe is also equipped with a temperature sensor to automatically compensate measurements against temperature changes from 5 to 50°C (41 to 122°F).

When operating in the measurement mode. HI 983304-01’s red LED will alert the user as soon as the reading is 1 µS/cm over the setpoint.

Order Information:
HI 983304-01 (115V) and HI 983304-02 (230V) are supplied with HI 7631/2 EC/TDS probe. calibration screwdriver. 12 VDC adapter and instructions.

SPECIFICATIONS:

Range   0.00 to 19.99 µS/cm
Resolution   0.01 µS/cm
Accuracy   ±2% F.S.
Calibration   manual. 1 point through trimmer
Temperature Compensation   automatic. 5 to 50°C (41 to 122°F) with ß=2.4%/°C
Setpoint   1.00 to 5.00 µS/cm
Alarm   red LED (blinks when measurement differs from setpoint by:
±1.00 µS/cm
EC Probe   HI 7631/2 with 2 m (6.6') cable and ½" thread
(included)
Power Supply   12 Vdc power adapter (included)
Environment   0 to 50°C (32 to 122°F); RH max 100%
Dimensions   86 x 110 x 43 mm (3.4 x 4.3 x 1.7")
Weight   215 g (7.6 oz.)

This product is available upon request. Contact us for more information.