Email info@acornsci.com for orders and inquiries.

{"id":2012186821,"title":"HANNA HI1005 pH Electrode. Flow-thru Monitoring for PCA","handle":"hi1005","description":"\u003cp\u003eFlow-thru monitoring pH electrode with DIN connection and 0.5 m cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e ½\" NPT external thread for in-line installation\u003c\/li\u003e\n\u003cli\u003epH electrode with exclusive PTFE non-clogging membrane\u003c\/li\u003e\n\u003cli\u003eDouble-junction technology\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003eModels with built-in matching pin and amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).\u003c\/p\u003e\n\u003cp\u003eBoth pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.\u003c\/p\u003e\n\u003cp\u003eHI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH\/ORP meter quick and easy.\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003edouble. PTFE\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epolymer\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e-5 to 80°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e6 bar (87 psi)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eBNC\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e3 m\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2021-08-24T12:02:06+12:00","created_at":"2015-09-04T15:21:03+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Category_pH","Manufacturer_Hanna Instruments","Type_Probes"],"price":19900,"price_min":19900,"price_max":19900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5764411717,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI1005","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI1005 pH Electrode. Flow-thru Monitoring for PCA","public_title":null,"options":["Default Title"],"price":19900,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hi1005_400-1_2015.jpeg?v=1465536295","\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e58d2a3d462_2015.jpeg?v=1465536296"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi1005_400-1_2015.jpeg?v=1465536295","options":["Title"],"media":[{"alt":"HI 1005 - pH Electrode. Flow-thru Monitoring for PCA - Acorn Scientific","id":25184731235,"position":1,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi1005_400-1_2015.jpeg?v=1465536295"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi1005_400-1_2015.jpeg?v=1465536295","width":400},{"alt":"HI 1005 - pH Electrode. Flow-thru Monitoring for PCA - Acorn Scientific","id":25184764003,"position":2,"preview_image":{"aspect_ratio":1.0,"height":400,"width":400,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e58d2a3d462_2015.jpeg?v=1465536296"},"aspect_ratio":1.0,"height":400,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e58d2a3d462_2015.jpeg?v=1465536296","width":400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eFlow-thru monitoring pH electrode with DIN connection and 0.5 m cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e ½\" NPT external thread for in-line installation\u003c\/li\u003e\n\u003cli\u003epH electrode with exclusive PTFE non-clogging membrane\u003c\/li\u003e\n\u003cli\u003eDouble-junction technology\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003eModels with built-in matching pin and amplifier\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eIn order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).\u003c\/p\u003e\n\u003cp\u003eBoth pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.\u003c\/p\u003e\n\u003cp\u003eHI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH\/ORP meter quick and easy.\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eJunction\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003edouble. PTFE\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eElectrolyte\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003epolymer\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e-5 to 80°C\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e6 bar (87 psi)\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003eBNC\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cspan style=\"font-size: small;\"\u003e3 m\u003c\/span\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}

HANNA HI1005 pH Electrode. Flow-thru Monitoring for PCA

Product Description

Flow-thru monitoring pH electrode with DIN connection and 0.5 m cable.

  •  ½" NPT external thread for in-line installation
  • pH electrode with exclusive PTFE non-clogging membrane
  • Double-junction technology
  • PVDF body
  • Models with built-in matching pin and amplifier

 

In order to reduce normal contamination coming from industrial use. these electrodes combine a polymer reference and double-junction technology. With this technology. no refilling is required and the electrode can be used in samples such as organic compounds. proteins and heavy metals. In addition. the pH electrodes use a unique annular PTFE junction that minimizes clogging. These industrial probes have a glass body electrode for use in aggressive chemicals and are easy to clean. A PEI protective sleeve gives the electrodes resistance against mechanical stress. Operating limits are -5 to 80°C (23 to 176°F) and pressure up to 6 bar (87 psi).

Both pH and ORP models are available. many of which include a built-in matching pin. Some models also feature a built-in amplifier. which allows for measurements to be taken far from the location of the instrument without requiring a transmitter.

HI 1000 and HI 2000 series incorporate a BNC connector that enables connection to any pH/ORP meter quick and easy.

Junction   double. PTFE
Electrolyte   polymer
Temperature   -5 to 80°C
Max Pressure   6 bar (87 psi)
Connection   BNC
Cable   3 m

 

This product is available upon request. Contact us for more information.