Email info@acornsci.com for orders and inquiries.

{"id":1582170501,"title":"HANNA HI 3850 Ascorbic Acid Test Kit","handle":"hi3850","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003e\u003cspan id=\"s7y714_3\" class=\"s7y714\"\u003eAscorbic acid\u003c\/span\u003e (C\u003csub\u003e6\u003c\/sub\u003eH\u003csub\u003e8\u003c\/sub\u003eO\u003csub\u003e6\u003c\/sub\u003e) undergoes an oxidation reaction with potassium iodate in acidic condition.\u003c\/p\u003e\n\u003cp\u003eThe endpoint is indicated by the reaction of iodine with starch suspension. which produces a blue-black product. As long as ascorbic acid is present. the triiodide is quickly converted to iodide ion. and no blue-black iodine-starch product is observed. However. when all the ascorbic acid has been oxidized. the excess triiodide (in equilibrium with iodine) reacts with starch to form the expected blue-black color.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 3850 test kit comes with 100 mL ascorbic acid reagent A. 25 mL starch indicator. 100 mL ascorbic acid reagent C. 50 mL calibrated plastic vessels (2). 3 mL plastic pipette. 1 mL plastic pipette (2) and graduated \u003cspan id=\"s7y714_1\" class=\"s7y714\"\u003eplastic test tube\u003c\/span\u003e with cap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10-200 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest Increment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Tests\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eapprox. 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e519 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:09:51+12:00","created_at":"2015-09-01T15:16:19+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Chemical Test Kits"],"price":15750,"price_min":15750,"price_max":15750,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857303621,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI3850","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 3850 Ascorbic Acid Test Kit","public_title":null,"options":["Default Title"],"price":15750,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/HI3850_200_2015.jpeg?v=1465536747"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI3850_200_2015.jpeg?v=1465536747","options":["Title"],"media":[{"alt":"HI 3850 Ascorbic Acid Test Kit - Acorn Scientific","id":21301395555,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI3850_200_2015.jpeg?v=1465536747"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI3850_200_2015.jpeg?v=1465536747","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003e\u003cspan id=\"s7y714_3\" class=\"s7y714\"\u003eAscorbic acid\u003c\/span\u003e (C\u003csub\u003e6\u003c\/sub\u003eH\u003csub\u003e8\u003c\/sub\u003eO\u003csub\u003e6\u003c\/sub\u003e) undergoes an oxidation reaction with potassium iodate in acidic condition.\u003c\/p\u003e\n\u003cp\u003eThe endpoint is indicated by the reaction of iodine with starch suspension. which produces a blue-black product. As long as ascorbic acid is present. the triiodide is quickly converted to iodide ion. and no blue-black iodine-starch product is observed. However. when all the ascorbic acid has been oxidized. the excess triiodide (in equilibrium with iodine) reacts with starch to form the expected blue-black color.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 3850 test kit comes with 100 mL ascorbic acid reagent A. 25 mL starch indicator. 100 mL ascorbic acid reagent C. 50 mL calibrated plastic vessels (2). 3 mL plastic pipette. 1 mL plastic pipette (2) and graduated \u003cspan id=\"s7y714_1\" class=\"s7y714\"\u003eplastic test tube\u003c\/span\u003e with cap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10-200 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSmallest Increment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e10 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eIodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Tests\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eapprox. 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e519 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 3850 Ascorbic Acid Test Kit

Product Description

 

Ascorbic acid (C6H8O6) undergoes an oxidation reaction with potassium iodate in acidic condition.

The endpoint is indicated by the reaction of iodine with starch suspension. which produces a blue-black product. As long as ascorbic acid is present. the triiodide is quickly converted to iodide ion. and no blue-black iodine-starch product is observed. However. when all the ascorbic acid has been oxidized. the excess triiodide (in equilibrium with iodine) reacts with starch to form the expected blue-black color.

 

Order Information:
HI 3850 test kit comes with 100 mL ascorbic acid reagent A. 25 mL starch indicator. 100 mL ascorbic acid reagent C. 50 mL calibrated plastic vessels (2). 3 mL plastic pipette. 1 mL plastic pipette (2) and graduated plastic test tube with cap.

SPECIFICATIONS:

Method   Titration
Range   10-200 mg/L
Smallest Increment   10 mg/L
Chemical Method   Iodometric
Number of Tests   approx. 100
Weight   519 g

This product is available upon request. Contact us for more information.