Email info@acornsci.com for orders and inquiries.

{"id":1582158789,"title":"HANNA HI 83203-02 Photometer for Aquaculture (13 Parameters)","handle":"hi83203-02","description":"\u003cp\u003eWith the ever increasing depletion of fish stocks in the open seas. aquaculture has gained prominence and can prove essential to our future dietary needs. Monitoring and controlling parameters such as the oxygen level as well as pH and nitrate content in water is vital in ensuring profitable fish production.\u003c\/p\u003e\n\u003cp\u003eAccurate control can prevent disease. increase production and even reduce the premiums on crop insurance. Research personnel. fish farm operators and wildlife specialists now have one compact and easy to use meter to keep a close tab on the most important parameters in aquaculture.\u003c\/p\u003e\n\u003cp\u003eHI 83203 is a multiparameter bench meter that measures thirteen methods essential for aquaculture analysis. It has four channels allowing for a wide range of tests.\u003c\/p\u003e\n\u003cp\u003eThe optical system of HI 83203 is based on special subminiature tungsten lamps and narrow-band interference filters to guarantee both high performance and reliable results.\u003c\/p\u003e\n\u003cp\u003eHI  83203 has a powerful interactive user support that assists the user during the analysis process. A full tutorial is available in the Setup Menu. and the Help Menu provides assistance for every step in the measurement process.This meter can be connected to a PC via a USB cable. where the data can be managed with optional HI 92000 Windows® compatible software.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 83203-02 (230V) are supplied with sample cuvettes and caps (2 ea.). cloth for wiping cuvettes. 60 mL glass bottle for dissolved oxygen analysis. scissors. AC\/DC power adapter. and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man83203_23_04_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eup to 5 tungsten lamps with different narrow band interference filters\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esilicon photocell\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); max 90% RH non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eexternal 12 VDC power adapter or built-in rechargeable battery\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e235 x 200 x 110 mm (9.2 x 7.87 x 4.33\")\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.9 Kg (2 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMulti Parameter Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eMethod\u003c\/th\u003e\n\u003cth\u003eReagent Code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 3.00 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93700-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 10.00 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChlorine. Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 2.50 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eDPD\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93701-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChlorine. Total\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 3.50 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eDPD\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93711-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCopper HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 5.00 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eBicinchoninate\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93702-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCopper LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 1000 µg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eBicinchoninate\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 95747-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 30.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrite HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 150 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eFerrous Sulfate\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93708-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrite LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 1.15 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eDiazotization\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93707-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOxygen. Dissolved (DO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 10.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eWinkler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93732-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e6.5 to 8.5 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003ePhenol Red\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93710-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphate HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 30.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93717-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphate LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 2.50 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAscorbic Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93713-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2026-06-25T16:18:57+12:00","created_at":"2015-09-01T15:14:49+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":92150,"price_min":92150,"price_max":92150,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857284677,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI83203-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 83203-02 Photometer for Aquaculture (13 Parameters)","public_title":null,"options":["Default Title"],"price":92150,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometre-multiparametre-pour-laquaculture-1016_1-1_2015.jpeg?v=1443495552"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometre-multiparametre-pour-laquaculture-1016_1-1_2015.jpeg?v=1443495552","options":["Title"],"media":[{"alt":"HANNA HI 83203-02 Photometer for Aquaculture (13 Parameters) - Acorn Scientific","id":21296775267,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometre-multiparametre-pour-laquaculture-1016_1-1_2015.jpeg?v=1443495552"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometre-multiparametre-pour-laquaculture-1016_1-1_2015.jpeg?v=1443495552","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eWith the ever increasing depletion of fish stocks in the open seas. aquaculture has gained prominence and can prove essential to our future dietary needs. Monitoring and controlling parameters such as the oxygen level as well as pH and nitrate content in water is vital in ensuring profitable fish production.\u003c\/p\u003e\n\u003cp\u003eAccurate control can prevent disease. increase production and even reduce the premiums on crop insurance. Research personnel. fish farm operators and wildlife specialists now have one compact and easy to use meter to keep a close tab on the most important parameters in aquaculture.\u003c\/p\u003e\n\u003cp\u003eHI 83203 is a multiparameter bench meter that measures thirteen methods essential for aquaculture analysis. It has four channels allowing for a wide range of tests.\u003c\/p\u003e\n\u003cp\u003eThe optical system of HI 83203 is based on special subminiature tungsten lamps and narrow-band interference filters to guarantee both high performance and reliable results.\u003c\/p\u003e\n\u003cp\u003eHI  83203 has a powerful interactive user support that assists the user during the analysis process. A full tutorial is available in the Setup Menu. and the Help Menu provides assistance for every step in the measurement process.This meter can be connected to a PC via a USB cable. where the data can be managed with optional HI 92000 Windows® compatible software.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 83203-02 (230V) are supplied with sample cuvettes and caps (2 ea.). cloth for wiping cuvettes. 60 mL glass bottle for dissolved oxygen analysis. scissors. AC\/DC power adapter. and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/man83203_23_04_10.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eup to 5 tungsten lamps with different narrow band interference filters\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esilicon photocell\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); max 90% RH non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eexternal 12 VDC power adapter or built-in rechargeable battery\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e235 x 200 x 110 mm (9.2 x 7.87 x 4.33\")\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.9 Kg (2 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eMulti Parameter Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eRange\u003c\/th\u003e\n\u003cth\u003eMethod\u003c\/th\u003e\n\u003cth\u003eReagent Code\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 3.00 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93700-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAmmonia MR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 10.00 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eNessler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93715-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChlorine. Free\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 2.50 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eDPD\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93701-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eChlorine. Total\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 3.50 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eDPD\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93711-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCopper HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 5.00 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eBicinchoninate\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93702-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCopper LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 1000 µg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eBicinchoninate\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 95747-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 30.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eCadmium Reduction\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93728-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrite HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 150 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eFerrous Sulfate\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93708-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNitrite LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 1.15 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eDiazotization\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93707-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOxygen. Dissolved (DO)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 10.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eWinkler\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93732-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e6.5 to 8.5 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003ePhenol Red\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93710-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphate HR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.0 to 30.0 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAmino Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93717-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePhosphate LR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 2.50 mg\/L (ppm)\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAscorbic Acid\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 93713-01\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}

HANNA HI 83203-02 Photometer for Aquaculture (13 Parameters)

Product Description

With the ever increasing depletion of fish stocks in the open seas. aquaculture has gained prominence and can prove essential to our future dietary needs. Monitoring and controlling parameters such as the oxygen level as well as pH and nitrate content in water is vital in ensuring profitable fish production.

Accurate control can prevent disease. increase production and even reduce the premiums on crop insurance. Research personnel. fish farm operators and wildlife specialists now have one compact and easy to use meter to keep a close tab on the most important parameters in aquaculture.

HI 83203 is a multiparameter bench meter that measures thirteen methods essential for aquaculture analysis. It has four channels allowing for a wide range of tests.

The optical system of HI 83203 is based on special subminiature tungsten lamps and narrow-band interference filters to guarantee both high performance and reliable results.

HI  83203 has a powerful interactive user support that assists the user during the analysis process. A full tutorial is available in the Setup Menu. and the Help Menu provides assistance for every step in the measurement process.This meter can be connected to a PC via a USB cable. where the data can be managed with optional HI 92000 Windows® compatible software.

 

Order Information:   HI 83203-02 (230V) are supplied with sample cuvettes and caps (2 ea.). cloth for wiping cuvettes. 60 mL glass bottle for dissolved oxygen analysis. scissors. AC/DC power adapter. and instruction manual.

Product Manuals

  Manual: Download

Specification :

Light Source   up to 5 tungsten lamps with different narrow band interference filters
Light Detector   silicon photocell
Environment   0 to 50°C (32 to 122°F); max 90% RH non-condensing
Power Supply   external 12 VDC power adapter or built-in rechargeable battery
Dimensions   235 x 200 x 110 mm (9.2 x 7.87 x 4.33")
Weight   0.9 Kg (2 lbs.)

Multi Parameter Specifications

Parameter Range Method Reagent Code
Ammonia LR 0.00 to 3.00 mg/L (ppm) Nessler HI 93700-01
Ammonia MR 0.00 to 10.00 mg/L (ppm) Nessler HI 93715-01
Chlorine. Free 0.00 to 2.50 mg/L (ppm) DPD HI 93701-01
Chlorine. Total 0.00 to 3.50 mg/L (ppm) DPD HI 93711-01
Copper HR 0.00 to 5.00 mg/L (ppm) Bicinchoninate HI 93702-01
Copper LR 0 to 1000 µg/L Bicinchoninate HI 95747-01
Nitrate 0.0 to 30.0 mg/L (ppm) Cadmium Reduction HI 93728-01
Nitrite HR 0 to 150 mg/L (ppm) Ferrous Sulfate HI 93708-01
Nitrite LR 0.00 to 1.15 mg/L (ppm) Diazotization HI 93707-01
Oxygen. Dissolved (DO) 0.0 to 10.0 mg/L (ppm) Winkler HI 93732-01
pH 6.5 to 8.5 pH Phenol Red HI 93710-01
Phosphate HR 0.0 to 30.0 mg/L (ppm) Amino Acid HI 93717-01
Phosphate LR 0.00 to 2.50 mg/L (ppm) Ascorbic Acid HI 93713-01

 