Email info@acornsci.com for orders and inquiries.

{"id":1582093893,"title":"HANNA HI 8731 Portable EC. TDS and Temperature Meter with extended ranges","handle":"hi8731","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eWatertight\u003c\/li\u003e\n\u003cli\u003eOn-screen operation guide\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eThese EC\/TDS meters are lightweight. water-tight and easy to maintain. Each desired measurement mode features its own key for quick selection.\u003c\/p\u003e\n\u003cp\u003eHI 8731 measures EC and TDS with extended ranges (from 0 to 6000 µS\/cm and from 0 to 3000 ppm. respectively).\u003c\/p\u003e\n\u003cp\u003eThe HI 761285 probe features a built-in temperature sensor and has been designed to require little maintenance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 8731 is supplied with HI 761285 conductivity probe. HI 70032 1382 mg\/L (ppm) calibration solution sachet. HI 70039 5000 µS\/cm calibration solution sachet. battery. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 6000 µS\/cm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 3000 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 70°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e10 µS\/cm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e10 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @ 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2% F.S.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2% F.S.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.5°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.5\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\/TDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eManual. one point. through front knob\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003efactory calibrated\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 761285 conductivity probe with internal temperature sensor. DIN connector and 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAutomatic. 0 to 50°C (32 to 122°F) with ß=2%\/°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.9V \/ approximately 200 hours of continuous use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e230 g (8.1 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070032P\"\u003eHI 70032P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1382 mg\/L (ppm) TDS Solution. (25) 20 mL Sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207032M\"\u003eHI 7032M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1382 mg\/L (ppm) TDS Solution. 230 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207032L\"\u003eHI 7032L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1382 mg\/L (ppm) TDS Bottle. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070039P\"\u003eHI 70039P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution (25) 20 mL Sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207039M\"\u003eHI 7039M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution. 230 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207039L\"\u003eHI 7039L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070031P\"\u003eHI 70031P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1413 µS\/cm EC Solution. (25) 20 mL Sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207031M\"\u003eHI 7031M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1413 µS\/cm EC Solution. 230 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207031L\"\u003eHI 7031L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1413 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070442P\"\u003eHI 70442P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 mg\/L (ppm) TDS Solution. (25) 20 mL Sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070442M\"\u003eHI 70442M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 mg\/L (ppm) TDS Solution. 230 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070442L\"\u003eHI 70442L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 mg\/L (ppm) TDS Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T16:29:21+12:00","created_at":"2015-09-01T15:06:21+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters"],"price":29550,"price_min":29550,"price_max":29550,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857141189,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI8731","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 8731 Portable EC. TDS and Temperature Meter with extended ranges","public_title":null,"options":["Default Title"],"price":29550,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/einfaches-ectds-handmessgerat-bis-6000-s-1060_1-1_2015.jpeg?v=1443494795"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/einfaches-ectds-handmessgerat-bis-6000-s-1060_1-1_2015.jpeg?v=1443494795","options":["Title"],"media":[{"alt":null,"id":21274984547,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/einfaches-ectds-handmessgerat-bis-6000-s-1060_1-1_2015.jpeg?v=1443494795"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/einfaches-ectds-handmessgerat-bis-6000-s-1060_1-1_2015.jpeg?v=1443494795","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e \u003c\/p\u003e\n\u003cdiv id=\"Product-Body\"\u003e\n\u003cul\u003e\n\u003cli\u003eWatertight\u003c\/li\u003e\n\u003cli\u003eOn-screen operation guide\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003eThese EC\/TDS meters are lightweight. water-tight and easy to maintain. Each desired measurement mode features its own key for quick selection.\u003c\/p\u003e\n\u003cp\u003eHI 8731 measures EC and TDS with extended ranges (from 0 to 6000 µS\/cm and from 0 to 3000 ppm. respectively).\u003c\/p\u003e\n\u003cp\u003eThe HI 761285 probe features a built-in temperature sensor and has been designed to require little maintenance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 8731 is supplied with HI 761285 conductivity probe. HI 70032 1382 mg\/L (ppm) calibration solution sachet. HI 70039 5000 µS\/cm calibration solution sachet. battery. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSPECIFICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\n\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 6000 µS\/cm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 3000 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 70°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e10 µS\/cm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e10 ppm\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @ 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2% F.S.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2% F.S.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.5°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.5\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eEC\/TDS\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eManual. one point. through front knob\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003efactory calibrated\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 761285 conductivity probe with internal temperature sensor. DIN connector and 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature\u003cbr\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eAutomatic. 0 to 50°C (32 to 122°F) with ß=2%\/°C\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.9V \/ approximately 200 hours of continuous use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e230 g (8.1 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\u003cth\u003eSolutions\u003c\/th\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070032P\"\u003eHI 70032P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1382 mg\/L (ppm) TDS Solution. (25) 20 mL Sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207032M\"\u003eHI 7032M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1382 mg\/L (ppm) TDS Solution. 230 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207032L\"\u003eHI 7032L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1382 mg\/L (ppm) TDS Bottle. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070039P\"\u003eHI 70039P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution (25) 20 mL Sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207039M\"\u003eHI 7039M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution. 230 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207039L\"\u003eHI 7039L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5000 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070031P\"\u003eHI 70031P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1413 µS\/cm EC Solution. (25) 20 mL Sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207031M\"\u003eHI 7031M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1413 µS\/cm EC Solution. 230 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%207031L\"\u003eHI 7031L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1413 µS\/cm EC Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070442P\"\u003eHI 70442P\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 mg\/L (ppm) TDS Solution. (25) 20 mL Sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070442M\"\u003eHI 70442M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 mg\/L (ppm) TDS Solution. 230 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.hannainst.com\/usa\/prods2.cfm?id=044009\u0026amp;ProdCode=HI%2070442L\"\u003eHI 70442L\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 mg\/L (ppm) TDS Solution. 500 mL Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e"}

HANNA HI 8731 Portable EC. TDS and Temperature Meter with extended ranges

Product Description

 

  • Watertight
  • On-screen operation guide
  • Automatic Temperature Compensation


These EC/TDS meters are lightweight. water-tight and easy to maintain. Each desired measurement mode features its own key for quick selection.

HI 8731 measures EC and TDS with extended ranges (from 0 to 6000 µS/cm and from 0 to 3000 ppm. respectively).

The HI 761285 probe features a built-in temperature sensor and has been designed to require little maintenance.

 

Order Information:
HI 8731 is supplied with HI 761285 conductivity probe. HI 70032 1382 mg/L (ppm) calibration solution sachet. HI 70039 5000 µS/cm calibration solution sachet. battery. instructions and rugged carrying case.

SPECIFICATIONS:

Range EC 0 to 6000 µS/cm
  TDS 0 to 3000 ppm
  Temperature 0 to 70°C
Resolution EC 10 µS/cm
  TDS 10 ppm
  Temperature 0.1°C
Accuracy @ 20°C EC ±2% F.S.
  TDS ±2% F.S.
  Temperature ±0.5°C
TDS Factor   0.5
Calibration EC/TDS Manual. one point. through front knob
  Temperature factory calibrated
Probe   HI 761285 conductivity probe with internal temperature sensor. DIN connector and 1 m (3.3’) cable (included)
Temperature
Compensation
  Automatic. 0 to 50°C (32 to 122°F) with ß=2%/°C
Environment   0 to 50°C (32 to 122°F); RH max 100%
Battery Type / Life   1.9V / approximately 200 hours of continuous use
Dimensions   145 x 80 x 36 mm (5.7 x 3.1 x 1.4’’)
Weight   230 g (8.1 oz.)
Solutions
HI 70032P 1382 mg/L (ppm) TDS Solution. (25) 20 mL Sachets
HI 7032M 1382 mg/L (ppm) TDS Solution. 230 mL Bottle
HI 7032L 1382 mg/L (ppm) TDS Bottle. 500 mL Bottle
HI 70039P 5000 µS/cm EC Solution (25) 20 mL Sachets
HI 7039M 5000 µS/cm EC Solution. 230 mL Bottle
HI 7039L 5000 µS/cm EC Solution. 500 mL Bottle
HI 70031P 1413 µS/cm EC Solution. (25) 20 mL Sachets
HI 7031M 1413 µS/cm EC Solution. 230 mL Bottle
HI 7031L 1413 µS/cm EC Solution. 500 mL Bottle
HI 70442P 1500 mg/L (ppm) TDS Solution. (25) 20 mL Sachets
HI 70442M 1500 mg/L (ppm) TDS Solution. 230 mL Bottle
HI 70442L 1500 mg/L (ppm) TDS Solution. 500 mL Bottle

This product is available upon request. Contact us for more information.