{"id":1582090117,"title":"HANNA HI 9126 pH\/mV\/°C Meter - CalCheck. waterproof","handle":"hi9126","description":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003epH Calibration Check™ \u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eElectrode condition monitoring\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eMeasurement store and recall\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBacklit. multi-level LCD display\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eReal time clock\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eUser-selectable calibration reminder\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eTutorial messages displayed on LCD\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBEPS; (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBattery % displayed on startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 9126 includes HANNA‘s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH electrode. Calibration Check™ warns users that maintenance may be needed.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eCalibrated buffers are continuously displayed in measurement mode to remind users of the instrument’s calibration point. Users can easily determine if readings are taken too far outside the calibration range.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 9126 can store and recall readings at the touch of a button.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 9126 utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for consistently accurate results. The HI 9126 can also measure ORP using optional probes.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e HI 9126 is supplied with HI 1230B pH electrode. HI 7662 temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer sachet. HI 700661 electrode cleaning solution sachet. 100 mL plastic beaker. batteries. instructions and hard carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-2.00 to 16.00 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eORP\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±699.9 mV; ±1999 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-20.0 to 120.0°C \/ -4.0°F to 248.0°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eORP\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mV; 1 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C \/ 0.1 °F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @ 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.01 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eORP\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2 mV; ±1 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.4°C\/±0.8°F (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Calibration Check\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eyes. check of the electrode status during calibration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. one or two point with seven memorized buffer values (pH 1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45) + 2 custom buffers\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eOffset\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eSlope\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003efrom 80 to 108%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic or manual. -20 to 120°C (-4 to 248°F) without temperature probe\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohms\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V (3) AAA \/ approximately 200 hours of continuous use without backlight (50 hours with backlight). auto-off after 20 minutes of non-use (can be disabled)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e300 g (10.6 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2026-06-25T16:29:32+12:00","created_at":"2015-09-01T15:05:45+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_pH \u0026 ORP Meters"],"price":87000,"price_min":87000,"price_max":87000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857132357,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI9126","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 9126 pH\/mV\/°C Meter - CalCheck. waterproof","public_title":null,"options":["Default Title"],"price":87000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/hand-phmv-meter-mit-multifunktionsdisplay-und-cal-check-1077_1-1_2015.jpeg?v=1443494756"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hand-phmv-meter-mit-multifunktionsdisplay-und-cal-check-1077_1-1_2015.jpeg?v=1443494756","options":["Title"],"media":[{"alt":"HI 9126 pH\/mV\/°C Meter - CalCheck. waterproof - Acorn Scientific","id":21273641059,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hand-phmv-meter-mit-multifunktionsdisplay-und-cal-check-1077_1-1_2015.jpeg?v=1443494756"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hand-phmv-meter-mit-multifunktionsdisplay-und-cal-check-1077_1-1_2015.jpeg?v=1443494756","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003epH Calibration Check™ \u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eElectrode condition monitoring\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eMeasurement store and recall\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBacklit. multi-level LCD display\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eReal time clock\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eUser-selectable calibration reminder\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eTutorial messages displayed on LCD\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBEPS; (Battery Error Prevention System) alerts the user in the event that low battery power could adversely affect readings.\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBattery % displayed on startup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 9126 includes HANNA‘s exclusive Calibration Check™ technology. Calibration Check™ monitors the pH bulb and reference junction of the electrode every time the instrument is calibrated. In the event of a dirty pH electrode. Calibration Check™ warns users that maintenance may be needed.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eCalibrated buffers are continuously displayed in measurement mode to remind users of the instrument’s calibration point. Users can easily determine if readings are taken too far outside the calibration range.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 9126 can store and recall readings at the touch of a button.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 9126 utilizes the HI 1230B double junction pH electrode. The double junction helps to minimize junction contamination for consistently accurate results. The HI 9126 can also measure ORP using optional probes.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e HI 9126 is supplied with HI 1230B pH electrode. HI 7662 temperature probe. HI 70004 pH 4.01 buffer solution sachet. HI 70007 pH 7.01 buffer sachet. HI 700661 electrode cleaning solution sachet. 100 mL plastic beaker. batteries. instructions and hard carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-2.00 to 16.00 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eORP\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±699.9 mV; ±1999 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-20.0 to 120.0°C \/ -4.0°F to 248.0°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eORP\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1 mV; 1 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C \/ 0.1 °F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @ 20°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.01 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eORP\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2 mV; ±1 mV\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.4°C\/±0.8°F (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Calibration Check\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eyes. check of the electrode status during calibration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003epH\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic. one or two point with seven memorized buffer values (pH 1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45) + 2 custom buffers\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eOffset\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1 pH\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u003cstrong\u003eSlope\u003c\/strong\u003e\u003c\/small\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003efrom 80 to 108%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic or manual. -20 to 120°C (-4 to 248°F) without temperature probe\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 1230B PEI body pH electrode with BNC connector and 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 7662 stainless steel temperature probe with 1 m (3.3’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e10\u003csup\u003e12\u003c\/sup\u003e Ohms\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V (3) AAA \/ approximately 200 hours of continuous use without backlight (50 hours with backlight). auto-off after 20 minutes of non-use (can be disabled)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e185 x 72 x 36 mm (7.3 x 2.8 x 1.4”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e300 g (10.6 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}
HANNA HI 9126 pH/mV/°C Meter - CalCheck. waterproof
Related Products
HANNA BL983320-1 Conductivity Mini Controller @ 199.9 µS/cm
$350.00 $465.00














