{"id":2031630405,"title":"HANNA HI 93414-02 Turbidity and Free\/Total Cl2 Portable Meter with CAL CHECK™ and Fast Tracker™. EPA Comp","handle":"hi93414-02","description":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eHigh accuracy at low ranges \u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eExclusive chlorine CAL CHECK™ calibration validation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eExclusive Fast Tracker™ system\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eUser replaceable light source\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eTwo. three or four point turbidity calibration\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eUSB and RS232 PC connectivity\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eGLP features\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eLogging for up to 200 readings\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eUser friendly. backlit display with guidance codes\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eAuto-off\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eBattery % on startup\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eContinuous current time on display\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003e \u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eThe HI 93414 measures the most important parameters of drinking water: turbidity and free\/total chlorine. Designed for water quality measurements. HI 93414 provides reliable and accurate readings on low turbidity and chlorine values. The HI 93414 meets and exceeds the requirements of USEPA and Standard Methods both for turbidity and colorimetric measurements.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eThis instrument incorporates an optical system which guarantees accurate results. The optical system. consisting of a tungsten filament lamp. three detectors (scattered. transmitted for turbidimeter range and one for colorimeter range). and a narrow band interference filter @ 525 nm assures long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the lamp. making no need for frequent calibration. The 25 mm round cuvettes made from special optical glass guarantee repeatability and consistency of measurements.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eTurbidity measurements can be made in the 0.00 to 1000 NTU (Nephelometric Turbidity Units) range. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Depending on the measured sample and needed accuracy. normal measurement. continuous measurement or signal averaging measurement can be selected. Free or total chlorine measurements can be made in the 0.00 to 5.00 mg\/L (ppm) range.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eAt startup. the meter displays the percentage of remaining battery life and. if too low. a 'low battery' warning message is displayed.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eWith the powerful CAL CHECK™ function. performance of the instrument can be validated at any time by using the exclusive HANNA ready-made NIST traceable standards. Calibration can be performed at any time for turbidity and colorimetric range. For turbidity. a two. three or four-point calibration is available using supplied (\u0026lt;0.1. 15. 100 and 750 NTU adjustable calibration points) or user prepared standards. For colorimeter measurements. a one-point calibration can be performed.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eHI 93414 has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points. time and date can be checked at the touch of a button. HI 93414 has a user-friendly interface with an easy to read. large (LCD). Displayed codes guide the user step by step with routine operation and through calibration. Confirmation and error acoustic signals aid the user during instrument operation.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eFor advanced field applications. the HI 93414 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eWith it’s logging function. up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003e \u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e HI 93414-02 (230V) is supplied with sample cuvettes and caps (5). calibration cuvettes for turbidimeter. calibration cuvettes for colorimeter. silicone oil. cuvette wiping tissue. scissors. batteries. AC adapter. instructions and rugged carrying case.\u003c\/p\u003e\u003cp\u003e\u003cimg width=\"364\" height=\"299\" class=\"tinymce-editor-image\" alt=\"93414\" src=\"media\/image\/93414.png\" data-mce-src=\"media\/image\/93414.png\"\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_93414.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/manHI_93414.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr data-mce-bogus=\"1\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 5.00 mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 mg\/L from 0.00 to 3.50 mg\/L; 0.10 above 3.50 mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @25°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2% of reading plus 0.02 NTU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.03 mg\/L ±3% of reading (whichever is greater)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eRatio Nephelometric Method (90°). ratio of scattered and transmitted light; adaptation of the USEPA Method 180.1 and Standard Method 2130 B\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eadaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u0026lt;0.1. 15. 100 and 750 NTU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1 mg\/L free chlorine. 1 mg\/L total chlorine\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003etwo. three or four-point calibration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eone-point calibration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esilicon photocell\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esilicon photocell with 525 nm narrow band interference filter\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurbidity Range Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStray Light\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u0026lt; 0.02 NTU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003enormal. average. continuous\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003etungsten filament lamp\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLamp Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003egreater than 100.000 readings\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLog Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e200 records\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eUSB or RS 232\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0°C (32°F) to 50°C (122°F); max 95% RH non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) \/ 512 g (18 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e","published_at":"2026-06-25T15:15:22+12:00","created_at":"2015-09-07T15:06:27+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Turbidity"],"price":210000,"price_min":210000,"price_max":210000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5832153797,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI93414-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 93414-02 Turbidity and Free\/Total Cl2 Portable Meter with CAL CHECK™ and Fast Tracker™. EPA Comp","public_title":null,"options":["Default Title"],"price":210000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/handmessgerat-fur-trubung-und-chlor-usepa-1101_1-1_2015.jpeg?v=1443494873","\/\/acornsci.co.nz\/cdn\/shop\/products\/1101_2-1_2015.jpeg?v=1443494873","\/\/acornsci.co.nz\/cdn\/shop\/products\/hi93414-1_2015.jpeg?v=1443494873"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/handmessgerat-fur-trubung-und-chlor-usepa-1101_1-1_2015.jpeg?v=1443494873","options":["Title"],"media":[{"alt":"HANNA HI 93414-02 Turbidity and Free\/Total Cl2 Portable Meter with CAL CHECK™ and Fast Tracker™. EPA Comp - Acorn Scientific","id":25251086435,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/handmessgerat-fur-trubung-und-chlor-usepa-1101_1-1_2015.jpeg?v=1443494873"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/handmessgerat-fur-trubung-und-chlor-usepa-1101_1-1_2015.jpeg?v=1443494873","width":800},{"alt":"HANNA HI 93414-02 Turbidity and Free\/Total Cl2 Portable Meter with CAL CHECK™ and Fast Tracker™. EPA Comp - Acorn Scientific","id":25251119203,"position":2,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/1101_2-1_2015.jpeg?v=1443494873"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/1101_2-1_2015.jpeg?v=1443494873","width":800},{"alt":"HANNA HI 93414-02 Turbidity and Free\/Total Cl2 Portable Meter with CAL CHECK™ and Fast Tracker™. EPA Comp - Acorn Scientific","id":25251151971,"position":3,"preview_image":{"aspect_ratio":1.0,"height":600,"width":600,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi93414-1_2015.jpeg?v=1443494873"},"aspect_ratio":1.0,"height":600,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/hi93414-1_2015.jpeg?v=1443494873","width":600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eHigh accuracy at low ranges \u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eExclusive chlorine CAL CHECK™ calibration validation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eExclusive Fast Tracker™ system\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eUser replaceable light source\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eTwo. three or four point turbidity calibration\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eUSB and RS232 PC connectivity\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eGLP features\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eLogging for up to 200 readings\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eUser friendly. backlit display with guidance codes\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eAuto-off\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eBattery % on startup\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eContinuous current time on display\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003e \u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eThe HI 93414 measures the most important parameters of drinking water: turbidity and free\/total chlorine. Designed for water quality measurements. HI 93414 provides reliable and accurate readings on low turbidity and chlorine values. The HI 93414 meets and exceeds the requirements of USEPA and Standard Methods both for turbidity and colorimetric measurements.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eThis instrument incorporates an optical system which guarantees accurate results. The optical system. consisting of a tungsten filament lamp. three detectors (scattered. transmitted for turbidimeter range and one for colorimeter range). and a narrow band interference filter @ 525 nm assures long term stability and minimizes stray light and color interferences. It also compensates for variations in intensity of the lamp. making no need for frequent calibration. The 25 mm round cuvettes made from special optical glass guarantee repeatability and consistency of measurements.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eTurbidity measurements can be made in the 0.00 to 1000 NTU (Nephelometric Turbidity Units) range. The instrument has an EPA compliance reading mode which rounds readings to meet EPA reporting requirements. Depending on the measured sample and needed accuracy. normal measurement. continuous measurement or signal averaging measurement can be selected. Free or total chlorine measurements can be made in the 0.00 to 5.00 mg\/L (ppm) range.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eAt startup. the meter displays the percentage of remaining battery life and. if too low. a 'low battery' warning message is displayed.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eWith the powerful CAL CHECK™ function. performance of the instrument can be validated at any time by using the exclusive HANNA ready-made NIST traceable standards. Calibration can be performed at any time for turbidity and colorimetric range. For turbidity. a two. three or four-point calibration is available using supplied (\u0026lt;0.1. 15. 100 and 750 NTU adjustable calibration points) or user prepared standards. For colorimeter measurements. a one-point calibration can be performed.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eHI 93414 has complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. The last calibration points. time and date can be checked at the touch of a button. HI 93414 has a user-friendly interface with an easy to read. large (LCD). Displayed codes guide the user step by step with routine operation and through calibration. Confirmation and error acoustic signals aid the user during instrument operation.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eFor advanced field applications. the HI 93414 is equipped with Fast Tracker™—Tag Identification System (T.I.S.) that makes data collecting and management simpler than ever. Fast Tracker™ allows users to record the time and location of a specific measurement or series of measurements.\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003eWith it’s logging function. up to 200 measurements along with it’s tagged locations can be stored in internal memory and consulted at any time. Data can be later transferred to a PC via RS232 or USB interface and HANNA HI 92000 software (optional).\u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003e \u003c\/p\u003e\u003cp style=\"text-align: justify;\" data-mce-style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e HI 93414-02 (230V) is supplied with sample cuvettes and caps (5). calibration cuvettes for turbidimeter. calibration cuvettes for colorimeter. silicone oil. cuvette wiping tissue. scissors. batteries. AC adapter. instructions and rugged carrying case.\u003c\/p\u003e\u003cp\u003e\u003cimg width=\"364\" height=\"299\" class=\"tinymce-editor-image\" alt=\"93414\" src=\"media\/image\/93414.png\" data-mce-src=\"media\/image\/93414.png\"\u003e\u003c\/p\u003e\u003cp\u003e \u003c\/p\u003e\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\u003cp\u003e\u003cimg width=\"20\" height=\"22\" align=\"absmiddle\" alt=\"\" src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" border=\"0\" data-mce-src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_93414.pdf\" target=\"_blank\" data-mce-href=\"http:\/\/www.hannainst.com\/manuals\/manHI_93414.pdf\"\u003eDownload\u003c\/a\u003e\u003cbr data-mce-bogus=\"1\"\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 5.00 mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU; 1 NTU from 100 to 1000 NTU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 mg\/L from 0.00 to 3.50 mg\/L; 0.10 above 3.50 mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy @25°C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±2% of reading plus 0.02 NTU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.03 mg\/L ±3% of reading (whichever is greater)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMethod\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eRatio Nephelometric Method (90°). ratio of scattered and transmitted light; adaptation of the USEPA Method 180.1 and Standard Method 2130 B\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eadaptation of the USEPA Method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and DPD reagent causes a pink tint in the sample.\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u0026lt;0.1. 15. 100 and 750 NTU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1 mg\/L free chlorine. 1 mg\/L total chlorine\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003etwo. three or four-point calibration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eone-point calibration\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Detector\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTurbidity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esilicon photocell\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eFree and Total Cl\u003csub\u003e2\u003c\/sub\u003e\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003esilicon photocell with 525 nm narrow band interference filter\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTurbidity Range Selection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStray Light\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e\u0026lt; 0.02 NTU\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasuring Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003enormal. average. continuous\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLight Source\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003etungsten filament lamp\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLamp Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003egreater than 100.000 readings\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLog Memory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e200 records\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eUSB or RS 232\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0°C (32°F) to 50°C (122°F); max 95% RH non-condensing\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.5V AA alkaline batteries (4) or AC adapter; auto-off after 15 minutes of non-use\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \/ Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e224 x 87 x 77 mm (8.8 x 3.4 x 3.0”) \/ 512 g (18 oz.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003cp\u003e\u003cbr mce_bogus=\"1\"\u003e\u003c\/p\u003e"}
HANNA HI 93414-02 Turbidity and Free/Total Cl2 Portable Meter with CAL CHECK™ and Fast Tracker™. EPA Comp
Related Products
HANNA BL983320-1 Conductivity Mini Controller @ 199.9 µS/cm
$350.00 $465.00














