{"id":2012204549,"title":"HANNA HI 93703-11 Portable Logging Turbidity Meter (ISO 7027)","handle":"hi93703-11","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003eHI 93703 series are microprocessor based turbidity meters that provide laboratory precision for field turbidity measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"hanna\"\u003eHANNA®\u003c\/span\u003e' HI 93703 is designed to provide you with a simple yet accurate way to test turbidity on-site.\u003c\/p\u003e\n\u003cp\u003eThese meters have two operating ranges; 0.00 to 50.00 FTUs. and 50 to 1000 FTUs that can accommodate the most turbid condition you may encounter.\u003c\/p\u003e\n\u003cp\u003eThe HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.\u003c\/p\u003e\n\u003cp\u003eThe HI 93703-11 enhanced version features a real-time clock and internal logging for up to 199 measurements.\u003c\/p\u003e\n\u003cp\u003eCollected data can be downloaded to your management system using the Windows\u003csup\u003e®\u003c\/sup\u003ecompatible HI 92000 software.\u003c\/p\u003e\n\u003cp\u003eBoth versions meet the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 93703-11 is supplied with glass cuvet. batteries and instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eDownloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 50.00 FTU;\u003cbr\u003e50 to 1000 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 FTU (0.00 to 50.00 FTU);\u003cbr\u003e1 FTU (50 to 1000 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.5 FTU or ±5% of reading (whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e3 points (0 FTU. 10 FTU and 500 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003einfrared LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLife of the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e199 measurements. on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ethrough serial port and HI 92000 Windows\u003csup\u003e®\u003c\/sup\u003e compatible software (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal Time Clock\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e4 x 1.5V AA \/ approx. 60 hours of continuous use or 900 measurements;\u003cbr\u003eautomatic shut-off after 5 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e220 x 82 x 66 mm (8.7 x 3.2 x 2.6\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e510 g (1.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e","published_at":"2026-06-25T15:21:33+12:00","created_at":"2015-09-04T15:25:08+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Turbidity"],"price":144400,"price_min":144400,"price_max":144400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5764542597,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI93703-11","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 93703-11 Portable Logging Turbidity Meter (ISO 7027)","public_title":null,"options":["Default Title"],"price":144400,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":[],"featured_image":null,"options":["Title"],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\u003cdiv id=\"Product-Body\"\u003e\n\u003cp\u003eHI 93703 series are microprocessor based turbidity meters that provide laboratory precision for field turbidity measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cspan class=\"hanna\"\u003eHANNA®\u003c\/span\u003e' HI 93703 is designed to provide you with a simple yet accurate way to test turbidity on-site.\u003c\/p\u003e\n\u003cp\u003eThese meters have two operating ranges; 0.00 to 50.00 FTUs. and 50 to 1000 FTUs that can accommodate the most turbid condition you may encounter.\u003c\/p\u003e\n\u003cp\u003eThe HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.\u003c\/p\u003e\n\u003cp\u003eThe HI 93703-11 enhanced version features a real-time clock and internal logging for up to 199 measurements.\u003c\/p\u003e\n\u003cp\u003eCollected data can be downloaded to your management system using the Windows\u003csup\u003e®\u003c\/sup\u003ecompatible HI 92000 software.\u003c\/p\u003e\n\u003cp\u003eBoth versions meet the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e\u003cbr\u003eHI 93703-11 is supplied with glass cuvet. batteries and instructions.\u003c\/p\u003e\n\u003c\/div\u003e\u003cdiv id=\"TabbedPanels1\" class=\"TabbedPanels\"\u003e\n\u003cul class=\"TabbedPanelsTabGroup\"\u003e\n\u003cli class=\"TabbedPanelsTab TabbedPanelsTabSelected\"\u003eSpecifications\u003c\/li\u003e\n\u003cli class=\"TabbedPanelsTab\"\u003eDownloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"TabbedPanelsContentGroup\"\u003e\u003cdiv class=\"TabbedPanelsContent TabbedPanelsContentVisible\"\u003e\u003ctable class=\"spec_table mceItemTable\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 50.00 FTU;\u003cbr\u003e50 to 1000 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 FTU (0.00 to 50.00 FTU);\u003cbr\u003e1 FTU (50 to 1000 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.5 FTU or ±5% of reading (whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e3 points (0 FTU. 10 FTU and 500 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003einfrared LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLife of the instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e199 measurements. on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Connection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ethrough serial port and HI 92000 Windows\u003csup\u003e®\u003c\/sup\u003e compatible software (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReal Time Clock\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e4 x 1.5V AA \/ approx. 60 hours of continuous use or 900 measurements;\u003cbr\u003eautomatic shut-off after 5 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e220 x 82 x 66 mm (8.7 x 3.2 x 2.6\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e510 g (1.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e"}
HANNA HI 93703-11 Portable Logging Turbidity Meter (ISO 7027)
Related Products
HANNA BL983320-1 Conductivity Mini Controller @ 199.9 µS/cm
$350.00 $465.00














