{"id":1582099717,"title":"HANNA HI 93703C Turbidimeter ISO 7027 with Calibration Standard \u0026 Casing","handle":"hi93703c","description":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eGLP Features\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003e3 point calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHANNA instruments has chosen 10 FTU* as the calibration point because it is the value that best fits the water turbidity measurements in different applications. from drinking water to wastewater treatment. HANNA instruments uses the primary standard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a very toxic. unstable substance which requires particular care: its standards have to be prepared only a few minutes before performing the calibration. and cannot be reused because of their short life. HANNA AMCO-AEPA-1 standards are extremely stable. can be reused. and last up to six months if free from contamination. HI 93703 can be used with both standards.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eIt meets the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e*FTU is equivalent to the other internationally recognized unit NTU (Nephelometric Turbidity Unit. \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 93703C\u003c\/strong\u003e. kit including HI 93703 and HI 731313 maintenance kit.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_93703.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 50.00 FTU; 50 to 1000 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 FTU (0.00 to 50.00 FTU); 1 FTU (50 to 1000 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.5 FTU or ±5% of reading (whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e3 points (0 FTU. 10 FTU and 500 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003einfrared LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V AA (4) \/approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e220 x 82 x 66 mm (8.7 x 3.2 x 2.6\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e510 g (1.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","published_at":"2026-06-25T16:29:03+12:00","created_at":"2015-09-01T15:07:20+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Turbidity"],"price":159000,"price_min":159000,"price_max":159000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857161029,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI93703C","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 93703C Turbidimeter ISO 7027 with Calibration Standard \u0026 Casing","public_title":null,"options":["Default Title"],"price":159000,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/einfaches-trubungs-handmessgerat-iso-7027-1135_1-1_2015_1ee1498c-fe46-4a14-afc7-6cb3042bfa21.jpeg?v=1443494879"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/einfaches-trubungs-handmessgerat-iso-7027-1135_1-1_2015_1ee1498c-fe46-4a14-afc7-6cb3042bfa21.jpeg?v=1443494879","options":["Title"],"media":[{"alt":"HANNA HI 93703C Turbidimeter ISO 7027 with Calibration Standard \u0026 Casing - Acorn Scientific","id":21277016163,"position":1,"preview_image":{"aspect_ratio":0.808,"height":800,"width":646,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/einfaches-trubungs-handmessgerat-iso-7027-1135_1-1_2015_1ee1498c-fe46-4a14-afc7-6cb3042bfa21.jpeg?v=1443494879"},"aspect_ratio":0.808,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/einfaches-trubungs-handmessgerat-iso-7027-1135_1-1_2015_1ee1498c-fe46-4a14-afc7-6cb3042bfa21.jpeg?v=1443494879","width":646}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eGLP Features\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003e3 point calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 93703 series are microprocessor based turbidity meters that provide laboratory accuracy for field turbidity measurements.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 93703 is easy to calibrate (with 3 point calibration) using AMCO-EPA standards and is ISO 7027 compliant.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHANNA instruments has chosen 10 FTU* as the calibration point because it is the value that best fits the water turbidity measurements in different applications. from drinking water to wastewater treatment. HANNA instruments uses the primary standard AMCO-AEPA-1 to avoid all formazine-related problems. Formazine is a very toxic. unstable substance which requires particular care: its standards have to be prepared only a few minutes before performing the calibration. and cannot be reused because of their short life. HANNA AMCO-AEPA-1 standards are extremely stable. can be reused. and last up to six months if free from contamination. HI 93703 can be used with both standards.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eIt meets the requirements of GLP (Good Laboratory Practice) protocols for last calibration data storage.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e*FTU is equivalent to the other internationally recognized unit NTU (Nephelometric Turbidity Unit. \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 93703C\u003c\/strong\u003e. kit including HI 93703 and HI 731313 maintenance kit.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_93703.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 50.00 FTU; 50 to 1000 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 FTU (0.00 to 50.00 FTU); 1 FTU (50 to 1000 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.5 FTU or ±5% of reading (whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e3 points (0 FTU. 10 FTU and 500 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003einfrared LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detection\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon Photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V AA (4) \/approximately 60 hours of continuous use or 900 measurements; auto-off after 5 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e220 x 82 x 66 mm (8.7 x 3.2 x 2.6\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e510 g (1.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e"}
HANNA HI 93703C Turbidimeter ISO 7027 with Calibration Standard & Casing
Related Products
HANNA BL983320-1 Conductivity Mini Controller @ 199.9 µS/cm
$350.00 $465.00














