{"id":1582148229,"title":"HANNA HI 96701 Chlorine Free 0.00 - 5.00 mg\/l - Photometer","handle":"hi96701","description":"\u003cp\u003eChlorine is widely used in making many everyday products. but most notably. it is used for producing safe drinking water the world over. Even the smallest water supplies are now usually chlorinated. It is also extensively used in the production of paper products. dyestuffs. textiles. petroleum products. medicines. antiseptics. insecticides. food. solvents. paints. plastics. and many other consumer products. Most of the chlorine produced is used in the manufacture of chlorinated compounds for sanitation. pulp bleaching. disinfectants. and textile processing.\u003c\/p\u003e\n\u003cp\u003eOrganic chemistry demands much from chlorine. both as an oxidizing agent and in substitution. since it often brings many desired properties in an organic compound when substituted for hydrogen. as in one form of synthetic rubber.\u003c\/p\u003e\n\u003cp\u003eThe HI 96701 meter measures the free chlorine (Cl\u003csub\u003e2\u003c\/sub\u003e) content in water samples in the 0.00 to 5.00 mg\/L (ppm) range.\u003c\/p\u003e\n\u003cp\u003eThis meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCAL CHECK™\u003c\/li\u003e\n\u003cli\u003eUser calibration\u003c\/li\u003e\n\u003cli\u003eCertified calibration and verification standards\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System)\u003c\/li\u003e\n\u003cli\u003eTIMER function\u003c\/li\u003e\n\u003cli\u003eAuto shut-off\u003c\/li\u003e\n\u003cli\u003eGLP Features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96701\u003c\/strong\u003e is supplied with sample cuvettes with caps (2). 9V battery and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96701_24_01_11.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L from 0.00 to 3.50 mg\/L;0.10 mg\/L above 3.50 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ± 3% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003etungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 525nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 minutes of non-use in measurement mode; After 1 hour of non-use in calibration mode; with last reading reminder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the USEPA method 330.5 and Standard Method 4500-Cl G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","published_at":"2026-06-25T16:19:19+12:00","created_at":"2015-09-01T15:13:47+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":40660,"price_min":40660,"price_max":40660,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857265605,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96701","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 96701 Chlorine Free 0.00 - 5.00 mg\/l - Photometer","public_title":null,"options":["Default Title"],"price":40660,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e52aae30b7a_2015.jpeg?v=1443495418"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e52aae30b7a_2015.jpeg?v=1443495418","options":["Title"],"media":[{"alt":"HANNA HI 96701 Chlorine Free 0.00 - 5.00 mg\/l - Photometer - Acorn Scientific","id":21294252131,"position":1,"preview_image":{"aspect_ratio":1.028,"height":800,"width":822,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e52aae30b7a_2015.jpeg?v=1443495418"},"aspect_ratio":1.028,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e52aae30b7a_2015.jpeg?v=1443495418","width":822}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eChlorine is widely used in making many everyday products. but most notably. it is used for producing safe drinking water the world over. Even the smallest water supplies are now usually chlorinated. It is also extensively used in the production of paper products. dyestuffs. textiles. petroleum products. medicines. antiseptics. insecticides. food. solvents. paints. plastics. and many other consumer products. Most of the chlorine produced is used in the manufacture of chlorinated compounds for sanitation. pulp bleaching. disinfectants. and textile processing.\u003c\/p\u003e\n\u003cp\u003eOrganic chemistry demands much from chlorine. both as an oxidizing agent and in substitution. since it often brings many desired properties in an organic compound when substituted for hydrogen. as in one form of synthetic rubber.\u003c\/p\u003e\n\u003cp\u003eThe HI 96701 meter measures the free chlorine (Cl\u003csub\u003e2\u003c\/sub\u003e) content in water samples in the 0.00 to 5.00 mg\/L (ppm) range.\u003c\/p\u003e\n\u003cp\u003eThis meter uses an exclusive positive-locking system to ensure that the cuvette is in the same place every time it is placed into the measurement cell.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCAL CHECK™\u003c\/li\u003e\n\u003cli\u003eUser calibration\u003c\/li\u003e\n\u003cli\u003eCertified calibration and verification standards\u003c\/li\u003e\n\u003cli\u003eBEPS (Battery Error Prevention System)\u003c\/li\u003e\n\u003cli\u003eTIMER function\u003c\/li\u003e\n\u003cli\u003eAuto shut-off\u003c\/li\u003e\n\u003cli\u003eGLP Features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96701\u003c\/strong\u003e is supplied with sample cuvettes with caps (2). 9V battery and instruction manual.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96701_24_01_11.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L from 0.00 to 3.50 mg\/L;0.10 mg\/L above 3.50 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ± 3% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003etungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 525nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 minutes of non-use in measurement mode; After 1 hour of non-use in calibration mode; with last reading reminder.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the USEPA method 330.5 and Standard Method 4500-Cl G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e"}
HANNA HI 96701 Chlorine Free 0.00 - 5.00 mg/l - Photometer
Related Products
HANNA BL983320-1 Conductivity Mini Controller @ 199.9 µS/cm
$350.00 $465.00














