{"id":2012148549,"title":"HANNA HI 96717C Phosphate HR 0.0-30.0 mg\/L - Photometer with Cal kits \u0026 Casing","handle":"hi96717c","description":"\u003cp\u003ePhosphates are particularly important for the growth and development of plant roots. and hence are one of the most common fertilizers used in agriculture.\u003c\/p\u003e\n\u003cp\u003ePhosphates are also utilized in detergents and are needed. in small quantities. for heating systems. However. high concentrations of phosphates can cause environmental pollution as they are a primary cause of eutrophication.\u003c\/p\u003e\n\u003cp\u003eFor these reasons. it is necessary to closely monitor the phosphate levels present in both municipal and industrial waste water.\u003c\/p\u003e\n\u003cp\u003eThe HI 96717 measures the phosphate (PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3–\u003c\/sup\u003e) content in water samples in the 0.0 to 30.0 mg\/L (ppm) range. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96717C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96717_19_01_11.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1.0 mg\/L ±4% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAmino Acid Method. adapted from Standard Method for the Examination of Water and Wastewater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Shut off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","published_at":"2026-06-25T15:26:25+12:00","created_at":"2015-09-04T15:10:50+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":65550,"price_min":65550,"price_max":65550,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":5764117381,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96717C","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 96717C Phosphate HR 0.0-30.0 mg\/L - Photometer with Cal kits \u0026 Casing","public_title":null,"options":["Default Title"],"price":65550,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_65ee0245-b109-42b4-9089-fb3fd271807f.jpeg?v=1443494621","\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-phosphat-bis-300-mgl-1329_1-151d01b505c043_2015.jpeg?v=1443494621"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_65ee0245-b109-42b4-9089-fb3fd271807f.jpeg?v=1443494621","options":["Title"],"media":[{"alt":"HANNA HI 96717C Phosphate HR 0.0-30.0 mg\/L - Photometer with Cal kits \u0026 Casing - Acorn Scientific","id":25182765155,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_65ee0245-b109-42b4-9089-fb3fd271807f.jpeg?v=1443494621"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-ammonium-bis-300-mgl-im-koffer-1285_1-151cfd0ca96a88_2015_65ee0245-b109-42b4-9089-fb3fd271807f.jpeg?v=1443494621","width":800},{"alt":"HANNA HI 96717C Phosphate HR 0.0-30.0 mg\/L - Photometer with Cal kits \u0026 Casing - Acorn Scientific","id":25182797923,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1000,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-phosphat-bis-300-mgl-1329_1-151d01b505c043_2015.jpeg?v=1443494621"},"aspect_ratio":1.0,"height":1000,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-phosphat-bis-300-mgl-1329_1-151d01b505c043_2015.jpeg?v=1443494621","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003ePhosphates are particularly important for the growth and development of plant roots. and hence are one of the most common fertilizers used in agriculture.\u003c\/p\u003e\n\u003cp\u003ePhosphates are also utilized in detergents and are needed. in small quantities. for heating systems. However. high concentrations of phosphates can cause environmental pollution as they are a primary cause of eutrophication.\u003c\/p\u003e\n\u003cp\u003eFor these reasons. it is necessary to closely monitor the phosphate levels present in both municipal and industrial waste water.\u003c\/p\u003e\n\u003cp\u003eThe HI 96717 measures the phosphate (PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3–\u003c\/sup\u003e) content in water samples in the 0.0 to 30.0 mg\/L (ppm) range. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96717C\u003c\/strong\u003e includes photometer. sample cuvettes with caps (2 ea.). 9V battery. scissors. cloth for wiping cuvettes. instrument quality certificate. instruction manual and rigid carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/ist96717_19_01_11.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±1.0 mg\/L ±4% of reading @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTungsten lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAmino Acid Method. adapted from Standard Method for the Examination of Water and Wastewater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Shut off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e"}
HANNA HI 96717C Phosphate HR 0.0-30.0 mg/L - Photometer with Cal kits & Casing
Related Products
HANNA BL983320-1 Conductivity Mini Controller @ 199.9 µS/cm
$350.00 $465.00














