Email info@acornsci.com for orders and inquiries.

{"id":1582142917,"title":"HANNA HI 96735C Hardness Total - Photometer with Cal kit \u0026 Casing","handle":"hi96735c","description":"\u003cp\u003eTotal hardness. that is the presence of magnesium and calcium. is due mainly to the runoff water dissolving these salts as it flows or filters through different strata. Hardness can also cause scaling of pipes in cooling and heating systems.\u003c\/p\u003e\n\u003cp\u003eThe HI 93735 measures the total hardness in drinking. surface and wastewater.\u003c\/p\u003e\n\u003cp\u003eThis meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96735C\u003c\/strong\u003e is supplied with sample cuvettes with caps (2). 9V battery. cuvette cleaning cloth. quality certificate. instruction manual and rigid carrying case\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLR 0 to 250 mg\/L; MR 200 to 500 mg\/L; HR 400 to 750 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.0 mg\/L from 1 to 100 mg\/L; 5.0 mg\/Lfrom 100 to 750 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLR ±5mg\/L ±4% of reading@ 25°C; MR ±7 mg\/L ±3% of reading@ 25°C; HR ±10 mg\/L ±2% of reading@ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003elight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 466 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA recommended method 130.1. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Shut off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour  of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e.\u003c\/p\u003e","published_at":"2026-06-25T16:19:30+12:00","created_at":"2015-09-01T15:13:16+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Photometer"],"price":65550,"price_min":65550,"price_max":65550,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857253445,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI96735C","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 96735C Hardness Total - Photometer with Cal kit \u0026 Casing","public_title":null,"options":["Default Title"],"price":65550,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e5057205d53_2015_5a6a1a9c-1836-404f-ab0d-f2486c832fa1.jpeg?v=1443495384"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e5057205d53_2015_5a6a1a9c-1836-404f-ab0d-f2486c832fa1.jpeg?v=1443495384","options":["Title"],"media":[{"alt":"HANNA HI 96735C Hardness Total - Photometer with Cal kit \u0026 Casing - Acorn Scientific","id":21293072483,"position":1,"preview_image":{"aspect_ratio":1.028,"height":800,"width":822,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e5057205d53_2015_5a6a1a9c-1836-404f-ab0d-f2486c832fa1.jpeg?v=1443495384"},"aspect_ratio":1.028,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/photometer-farbe-von-honig-bis-150-mm-pfund-1433_151e5057205d53_2015_5a6a1a9c-1836-404f-ab0d-f2486c832fa1.jpeg?v=1443495384","width":822}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eTotal hardness. that is the presence of magnesium and calcium. is due mainly to the runoff water dissolving these salts as it flows or filters through different strata. Hardness can also cause scaling of pipes in cooling and heating systems.\u003c\/p\u003e\n\u003cp\u003eThe HI 93735 measures the total hardness in drinking. surface and wastewater.\u003c\/p\u003e\n\u003cp\u003eThis meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e \u003cstrong\u003eHI 96735C\u003c\/strong\u003e is supplied with sample cuvettes with caps (2). 9V battery. cuvette cleaning cloth. quality certificate. instruction manual and rigid carrying case\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLR 0 to 250 mg\/L; MR 200 to 500 mg\/L; HR 400 to 750 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.0 mg\/L from 1 to 100 mg\/L; 5.0 mg\/Lfrom 100 to 750 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eLR ±5mg\/L ±4% of reading@ 25°C; MR ±7 mg\/L ±3% of reading@ 25°C; HR ±10 mg\/L ±2% of reading@ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003elight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell with narrow band interference filter @ 466 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA recommended method 130.1. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e9V battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto-Shut off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use in measurement mode; after one hour  of non-use in calibration mode; with last reading reminder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e192 x 104 x 69 mm (7.6 x 4.1 x 2.7\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e360 g (12.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e.\u003c\/p\u003e"}

HANNA HI 96735C Hardness Total - Photometer with Cal kit & Casing

Product Description

Total hardness. that is the presence of magnesium and calcium. is due mainly to the runoff water dissolving these salts as it flows or filters through different strata. Hardness can also cause scaling of pipes in cooling and heating systems.

The HI 93735 measures the total hardness in drinking. surface and wastewater.

This meter uses an exclusive positive-locking system to ensure that the cuvette is in the same position every time it is placed into the measurement cell. It is designed to fit cuvettes with a larger neck making it easier to add both sample and reagents. The cuvettes are made from special optical glass to obtain best results.

 

Order Information: HI 96735C is supplied with sample cuvettes with caps (2). 9V battery. cuvette cleaning cloth. quality certificate. instruction manual and rigid carrying case

Specification :

Range   LR 0 to 250 mg/L; MR 200 to 500 mg/L; HR 400 to 750 mg/L
Resolution   1.0 mg/L from 1 to 100 mg/L; 5.0 mg/Lfrom 100 to 750 mg/L
Accuracy   LR ±5mg/L ±4% of reading@ 25°C; MR ±7 mg/L ±3% of reading@ 25°C; HR ±10 mg/L ±2% of reading@ 25°C
Light Source   light emitting diode
Light Detector   Silicon photocell with narrow band interference filter @ 466 nm
Method   Adaptation of the EPA recommended method 130.1. 
Environment   0 to 50°C (32 to 122°F); max 95% RH non-condensing
Power Supply   9V battery
Auto-Shut off   after ten minutes of non-use in measurement mode; after one hour  of non-use in calibration mode; with last reading reminder
Dimensions   192 x 104 x 69 mm (7.6 x 4.1 x 2.7")
Weight   360 g (12.7 oz.)

.

This product is available upon request. Contact us for more information.