{"id":1582071813,"title":"HANNA HI 98127 pH\/°C-Tester (0.1 pH resolution) - waterproof","handle":"hi98127","description":"\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eHI 98127\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cspan\u003e simultaneously measures pH and temperature with 0.1 resolution. \u003c\/span\u003e\u003cspan\u003eIt is easy to use. fast and accurate. and is therefore ideally suited for routine measurements. \u003c\/span\u003e\u003cspan\u003eWith replaceable electrode.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eDual display of pH and temperature\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eResolution of 0.1 pH\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eEasily replaceable electrode\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eAutomatic calibration and temperature compensation \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eStability indicator for safe values\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eHOLD function to freeze a reading in the display\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eBattery charge indicator and automatic shut-off\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrdering Information : \u003cspan\u003e\u003cspan class=\"goog-text-highlight\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"goog-text-highlight\"\u003eincl tester pH electrode. electrode replacement tool and batteries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003ca href=\"http:\/\/www.hannainst.com\/manuals\/IST98127_04_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-7_medium.png?11580704866198517246\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eSpecification: \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0°C \/ 23.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 20°C\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approximately 300 hours of continuous use; auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-5 to 50°C (23 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2016-07-12T14:35:00+12:00","created_at":"2015-09-01T15:03:00+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments"],"price":23300,"price_min":23300,"price_max":23300,"available":true,"price_varies":false,"compare_at_price":23300,"compare_at_price_min":23300,"compare_at_price_max":23300,"compare_at_price_varies":false,"variants":[{"id":4857056581,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI98127","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 98127 pH\/°C-Tester (0.1 pH resolution) - waterproof","public_title":null,"options":["Default Title"],"price":23300,"weight":0,"compare_at_price":23300,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/31nrgpdohcl_2015.jpeg?v=1443494490"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/31nrgpdohcl_2015.jpeg?v=1443494490","options":["Title"],"media":[{"alt":"HI 98127 pH\/°C-Tester (0.1 pH resolution) - waterproof - Acorn Scientific","id":21267939427,"position":1,"preview_image":{"aspect_ratio":1.0,"height":405,"width":405,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/31nrgpdohcl_2015.jpeg?v=1443494490"},"aspect_ratio":1.0,"height":405,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/31nrgpdohcl_2015.jpeg?v=1443494490","width":405}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eHI 98127\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cspan\u003e simultaneously measures pH and temperature with 0.1 resolution. \u003c\/span\u003e\u003cspan\u003eIt is easy to use. fast and accurate. and is therefore ideally suited for routine measurements. \u003c\/span\u003e\u003cspan\u003eWith replaceable electrode.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eDual display of pH and temperature\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eResolution of 0.1 pH\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eEasily replaceable electrode\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eAutomatic calibration and temperature compensation \u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eStability indicator for safe values\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eHOLD function to freeze a reading in the display\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003e\u003cspan\u003eBattery charge indicator and automatic shut-off\u003c\/span\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrdering Information : \u003cspan\u003e\u003cspan class=\"goog-text-highlight\"\u003e \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"goog-text-highlight\"\u003eincl tester pH electrode. electrode replacement tool and batteries.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003ca href=\"http:\/\/www.hannainst.com\/manuals\/IST98127_04_13.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-7_medium.png?11580704866198517246\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003cspan\u003eSpecification: \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0°C \/ 23.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy @ 20°C\u003c\/td\u003e\n\u003ctd\u003epH\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eTemperature\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eautomatic. at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type \/ Life\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approximately 300 hours of continuous use; auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e-5 to 50°C (23 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}