Email info@acornsci.com for orders and inquiries.

{"id":1582113221,"title":"HANNA HI 98186-02 Dissolved Oxygen \u0026 BOD Meter \/ °C - Meter. polarograpHANNA HIc DO probe","handle":"hi98186-02","description":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eExtended DO range up to 50 ppm and 600% saturation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBuilt-in barometer\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eSalinity. pressure and temperature compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBacklit. graphic LCD display\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eCalibration reminder\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eLog on demand (400 samples)\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAuto HOLD\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eGLP features\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003ePC connectivity via USB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 98186 portable Dissolved Oxygen Meter has extended ranges of up to 50 ppm or 600% saturation. This instrument includes barometric pressure measurement and calibration with a user selectable unit (mmHg. atm. mbar. psi. kPa) as well as a 1 or 2 point temperature calibration. Salinity. pressure and temperature compensations enhance the precision of your readings.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eWith its internal barometer. the instrument is able to automatically compensate for changes in barometric pressure so there is no need for charts. altitude information or external barometric pressure information. Salinity compensation in water allows direct determination of dissolved oxygen in saline waters.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eOther features include measurement and methods for BOD (biochemical oxygen demand). OUR (oxygen uptake rate). and SOUR (specific oxygen uptake rate).\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 98186’s log on-demand features allows users to store up to 400 samples that can be later transferred to a PC with the HI?920013 USB cable and HI 92000 software.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eAn “Out Of Calibration Range Warning” can be activated to alert the user in the event that a reading is taken too far from the calibration's periphery. A combination of dedicated and soft keys allows easy. intuitive operation in a choice of languages. Comprehensive GLP data is directly accessible by pressing the GLP key and a contextual Help menu can be access to obtain on-screen information and assistance about each feature at the touch of a button.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eDesigned for field use. this instrument can be easily operated with one hand and is housed in a rugged carrying case. The inductive charger can either be plugged into a standard 115V socket with the adapter included or a 12 VDC source. such as a car's 12 V accessory outlet.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 98186-02 (230V) is supplied with HI 76407\/4F DO probe. spare membranes (2). HI 7041S electrolyte solution (30 mL). rechargeable batteries. HI 710042 inductive battery charger with power adapter. 12 VDC adapter. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_98186.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 50.00 mg\/L (ppm); 0.0 to 600.0 % saturation\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 to 850 mmHg\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 mg\/L (ppm); 0.1% saturation\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1 mm Hg\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C\/°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1.5% of reading ±1 digit\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e± 3 mmHg within ±15% from the calibration point\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C\/±0.4°F (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edirect DO; BOD (biochemical oxygen demand);  OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e automatic one or two point at 100 % (8.26 mg\/L) and 0 %  (0 mg\/L).; manual one point using a value entered  by the user in % saturation or mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eone point at any in range pressure value\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eone or two point at any in range temperature value\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from 450 to 850 mmHg\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSalinity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from 0 to 70 g\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from 0.0 to 50.0 ºC (32.0 to 122.0 ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 76407\/4F polarographic DO probe with protective sleeve. internal  temperature sensor. DIN connector and 4m (13’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003elog on demand. 400 samples\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eopto-isolated USB (with HI?92000 software)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.2V (4) AA rechargeable batteries\/approximately 200 hours  of continuous use without backlight\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003euser selectable: 5. 10. 30. 60 min or can be disabled\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 – 50 ºC (32 – 122 ºF) RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e 525 g (1.1 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e","published_at":"2026-06-25T16:23:20+12:00","created_at":"2015-09-01T15:09:22+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Dissolved Oxygen"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857195973,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI98186-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 98186-02 Dissolved Oxygen \u0026 BOD Meter \/ °C - Meter. polarograpHANNA HIc DO probe","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/sauerstoff-handmessgerat-mit-pc-interface-1476_1-1_2015.jpeg?v=1443495080"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/sauerstoff-handmessgerat-mit-pc-interface-1476_1-1_2015.jpeg?v=1443495080","options":["Title"],"media":[{"alt":null,"id":21282324579,"position":1,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/sauerstoff-handmessgerat-mit-pc-interface-1476_1-1_2015.jpeg?v=1443495080"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/sauerstoff-handmessgerat-mit-pc-interface-1476_1-1_2015.jpeg?v=1443495080","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cul\u003e\n\u003cli style=\"text-align: justify;\"\u003eExtended DO range up to 50 ppm and 600% saturation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBuilt-in barometer\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eSalinity. pressure and temperature compensation\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eBacklit. graphic LCD display\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eCalibration reminder\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eLog on demand (400 samples)\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eAuto HOLD\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003eGLP features\u003c\/li\u003e\n\u003cli style=\"text-align: justify;\"\u003ePC connectivity via USB\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eHI 98186 portable Dissolved Oxygen Meter has extended ranges of up to 50 ppm or 600% saturation. This instrument includes barometric pressure measurement and calibration with a user selectable unit (mmHg. atm. mbar. psi. kPa) as well as a 1 or 2 point temperature calibration. Salinity. pressure and temperature compensations enhance the precision of your readings.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eWith its internal barometer. the instrument is able to automatically compensate for changes in barometric pressure so there is no need for charts. altitude information or external barometric pressure information. Salinity compensation in water allows direct determination of dissolved oxygen in saline waters.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eOther features include measurement and methods for BOD (biochemical oxygen demand). OUR (oxygen uptake rate). and SOUR (specific oxygen uptake rate).\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 98186’s log on-demand features allows users to store up to 400 samples that can be later transferred to a PC with the HI?920013 USB cable and HI 92000 software.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eAn “Out Of Calibration Range Warning” can be activated to alert the user in the event that a reading is taken too far from the calibration's periphery. A combination of dedicated and soft keys allows easy. intuitive operation in a choice of languages. Comprehensive GLP data is directly accessible by pressing the GLP key and a contextual Help menu can be access to obtain on-screen information and assistance about each feature at the touch of a button.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eDesigned for field use. this instrument can be easily operated with one hand and is housed in a rugged carrying case. The inductive charger can either be plugged into a standard 115V socket with the adapter included or a 12 VDC source. such as a car's 12 V accessory outlet.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   HI 98186-02 (230V) is supplied with HI 76407\/4F DO probe. spare membranes (2). HI 7041S electrolyte solution (30 mL). rechargeable batteries. HI 710042 inductive battery charger with power adapter. 12 VDC adapter. instructions and rugged carrying case.\u003c\/p\u003e\n\u003cdiv\u003e\u003cstrong\u003eProduct Manuals\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cimg src=\"http:\/\/www.hannainst.com\/usa\/images\/icon-pdf.gif\" alt=\"\" width=\"20\" height=\"22\" align=\"absmiddle\" border=\"0\"\u003e  Manual: \u003ca title=\"Download Product Manual\" href=\"http:\/\/www.hannainst.com\/manuals\/manHI_98186.pdf\" target=\"_blank\"\u003eDownload\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.00 to 50.00 mg\/L (ppm); 0.0 to 600.0 % saturation\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e450 to 850 mmHg\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.01 mg\/L (ppm); 0.1% saturation\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1 mm Hg\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0.1°C\/°F\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAccuracy (@20°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±1.5% of reading ±1 digit\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e± 3 mmHg within ±15% from the calibration point\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e±0.2°C\/±0.4°F (excluding probe error)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMeasurement Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003edirect DO; BOD (biochemical oxygen demand);  OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eDO\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e automatic one or two point at 100 % (8.26 mg\/L) and 0 %  (0 mg\/L).; manual one point using a value entered  by the user in % saturation or mg\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric Pressure\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eone point at any in range pressure value\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eone or two point at any in range temperature value\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCompensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eBarometric\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from 450 to 850 mmHg\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eSalinity\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from 0 to 70 g\/L\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003csmall\u003eTemperature\u003c\/small\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eautomatic from 0.0 to 50.0 ºC (32.0 to 122.0 ºF)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProbe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eHI 76407\/4F polarographic DO probe with protective sleeve. internal  temperature sensor. DIN connector and 4m (13’) cable (included)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003elog on demand. 400 samples\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC Connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003eopto-isolated USB (with HI?92000 software)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery Type \/ Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e1.2V (4) AA rechargeable batteries\/approximately 200 hours  of continuous use without backlight\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003euser selectable: 5. 10. 30. 60 min or can be disabled\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e0 – 50 ºC (32 – 122 ºF) RH max 100%\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e\u003csmall\u003e 525 g (1.1 lbs.)\u003c\/small\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/p\u003e"}

HANNA HI 98186-02 Dissolved Oxygen & BOD Meter / °C - Meter. polarograpHANNA HIc DO probe

Product Description
  • Extended DO range up to 50 ppm and 600% saturation
  • Built-in barometer
  • Salinity. pressure and temperature compensation
  • Backlit. graphic LCD display
  • Calibration reminder
  • Log on demand (400 samples)
  • Auto HOLD
  • GLP features
  • PC connectivity via USB

 

HI 98186 portable Dissolved Oxygen Meter has extended ranges of up to 50 ppm or 600% saturation. This instrument includes barometric pressure measurement and calibration with a user selectable unit (mmHg. atm. mbar. psi. kPa) as well as a 1 or 2 point temperature calibration. Salinity. pressure and temperature compensations enhance the precision of your readings.

With its internal barometer. the instrument is able to automatically compensate for changes in barometric pressure so there is no need for charts. altitude information or external barometric pressure information. Salinity compensation in water allows direct determination of dissolved oxygen in saline waters.

Other features include measurement and methods for BOD (biochemical oxygen demand). OUR (oxygen uptake rate). and SOUR (specific oxygen uptake rate).

The HI 98186’s log on-demand features allows users to store up to 400 samples that can be later transferred to a PC with the HI?920013 USB cable and HI 92000 software.

An “Out Of Calibration Range Warning” can be activated to alert the user in the event that a reading is taken too far from the calibration's periphery. A combination of dedicated and soft keys allows easy. intuitive operation in a choice of languages. Comprehensive GLP data is directly accessible by pressing the GLP key and a contextual Help menu can be access to obtain on-screen information and assistance about each feature at the touch of a button.

Designed for field use. this instrument can be easily operated with one hand and is housed in a rugged carrying case. The inductive charger can either be plugged into a standard 115V socket with the adapter included or a 12 VDC source. such as a car's 12 V accessory outlet.

 

 

Order Information:   HI 98186-02 (230V) is supplied with HI 76407/4F DO probe. spare membranes (2). HI 7041S electrolyte solution (30 mL). rechargeable batteries. HI 710042 inductive battery charger with power adapter. 12 VDC adapter. instructions and rugged carrying case.

Product Manuals

  Manual: Download

Specification :

Range DO 0.00 to 50.00 mg/L (ppm); 0.0 to 600.0 % saturation
  Barometric Pressure 450 to 850 mmHg
  Temperature -20.0 to 120.0°C (-4.0 to 248.0°F)
Resolution DO 0.01 mg/L (ppm); 0.1% saturation
  Barometric Pressure 1 mm Hg
  Temperature 0.1°C/°F
Accuracy (@20°C) DO ±1.5% of reading ±1 digit
  Barometric Pressure ± 3 mmHg within ±15% from the calibration point
  Temperature ±0.2°C/±0.4°F (excluding probe error)
Measurement Modes   direct DO; BOD (biochemical oxygen demand);  OUR (oxygen uptake rate); SOUR (specific oxygen uptake rate)
Calibration DO automatic one or two point at 100 % (8.26 mg/L) and 0 %  (0 mg/L).; manual one point using a value entered  by the user in % saturation or mg/L
  Barometric Pressure one point at any in range pressure value
  Temperature one or two point at any in range temperature value
Compensation Barometric automatic from 450 to 850 mmHg
  Salinity automatic from 0 to 70 g/L
  Temperature automatic from 0.0 to 50.0 ºC (32.0 to 122.0 ºF)
Probe   HI 76407/4F polarographic DO probe with protective sleeve. internal  temperature sensor. DIN connector and 4m (13’) cable (included)
Logging   log on demand. 400 samples
PC Connection   opto-isolated USB (with HI?92000 software)
Battery Type / Life   1.2V (4) AA rechargeable batteries/approximately 200 hours  of continuous use without backlight
Auto-off   user selectable: 5. 10. 30. 60 min or can be disabled
Environment   0 – 50 ºC (32 – 122 ºF) RH max 100%
Dimensions   226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)
Weight   525 g (1.1 lbs.)

 