{"id":5614020101,"title":"Jenway Genova Nano Micro-volume, Life Science \u0026 Standard Spectrophotometer in one","handle":"jenway-model-genova-nanodrop","description":"\u003cdiv align=\"left\"\u003eThis highly anticipated micro-volume spectrophotometer is a fusion of the high calibre Genova Plus life science spectrophotometer and Jenway's innovative micro-volume measurement accessory. Unlike any other micro-volume spectrophotometer on the market the Genova Nano can not only be used for micro-volume measurements but also temperature sensitive reactions due to its flexibility to be used with any of the accessories of Jenway's 73 series including the standard volume electronic Peltier. \u003cbr\u003e\u003cbr\u003eThe Genova Nano micro-volume spectrophotometer measures small sample volumes as low as 0.5µl with a high degree of accuracy, reproducibility and speed. It has the ability to measure small sample volumes, conserves precious samples, reduces the need for dilutions and eliminates the requirement for cuvettes. Cleaning is quick and simple; wiping the read heads with a microfibre cloth removes all trace of the sample, allowing faster change over between samples and therefore increasing sample throughput. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"left\"\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv align=\"left\"\u003e• Micro-volume, life science and standard spectrophotometer in 1\u003cbr\u003e• Ideal for DNA, RNA and Protein measurements\u003cbr\u003e• Only 0.5µl sample volume required\u003cbr\u003e• Purity scan over entire wavelength range, 198 to 1000nm\u003cbr\u003e• Detects DNA concentrations as low as 2ng\/µl \u003cbr\u003e• Easy and quick to clean\u003cbr\u003e• Results are reproducible, accurate and easily obtained\u003cbr\u003e• Method and result saving to USB memory stick \u003cbr\u003e• 3 year warranty including Xenon lamp\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"left\"\u003e\u003cb\u003e\u003cbr\u003eTechnical Specification\u003c\/b\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003ctable align=\"left\" width=\"100%\" cellpadding=\"4\" cellspacing=\"0\" id=\"Table4\" class=\"productborder\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eParameter\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eGenova Nano\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e198 to 1000nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e± 2nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSpectral Bandwidth \u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003ePath Length\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.2 or 0.5mm (auto-ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e- 15 to 125A (10mm equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e± 2% at 260nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eAbsorbance Precision\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u0026lt; 0.005A between 0 and 1A (at 260nm and 0.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMaximum Concentration\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e6,000 ng\/µl (dsDNA) (at 0.2mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDetection Limit\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e2.0ng\/µl (dsDNA) (at 0.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMeasurement Time\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u0026lt; 6.5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMinimum sample Size\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.5µl (at 0.2mm),1.0µl (at 0.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMaximum sample size\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5.0µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDNA measurement modes\u003c\/td\u003e\n\u003ctd align=\"left\"\u003edsDNA, ssDNA, RNA, Oligonucleotides, 260\/ 280, 260\/ 230, Variable ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eProtein measurement modes\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePierce 660, BCA, Bradford, Lowry, Biuret, Direct UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSample Pedestal Material \u003c\/td\u003e\n\u003ctd align=\"left\"\u003eQuartz stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eLight Source\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePress to read Xenon lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSize (w x d x h), mm\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e275 x 400 x 220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWeight, kg\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"left\"\u003eWhen the 10x10mm cuvette accessory is fitted the spectrophotometer conforms to the Genova Plus technical specification\u003c\/div\u003e","published_at":"2016-05-15T13:08:00+12:00","created_at":"2016-05-15T13:08:41+12:00","vendor":"Jenway","type":"Spectrophotometers","tags":["brand_Jenway","Category_Spectrophotometers","Manufacturer_Jenway","Type_Devices"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":17760518981,"title":"Jenway Model Genova NANODROP","option1":"Jenway Model Genova NANODROP","option2":null,"option3":null,"sku":"737 501","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Jenway Genova Nano Micro-volume, Life Science \u0026 Standard Spectrophotometer in one - Jenway Model Genova NANODROP","public_title":"Jenway Model Genova NANODROP","options":["Jenway Model Genova NANODROP"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/Screen_Shot_2016-05-17_at_1.28.08_pm.png?v=1463448513"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/Screen_Shot_2016-05-17_at_1.28.08_pm.png?v=1463448513","options":["Title"],"media":[{"alt":null,"id":53812527203,"position":1,"preview_image":{"aspect_ratio":1.45,"height":209,"width":303,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/Screen_Shot_2016-05-17_at_1.28.08_pm.png?v=1463448513"},"aspect_ratio":1.45,"height":209,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/Screen_Shot_2016-05-17_at_1.28.08_pm.png?v=1463448513","width":303}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv align=\"left\"\u003eThis highly anticipated micro-volume spectrophotometer is a fusion of the high calibre Genova Plus life science spectrophotometer and Jenway's innovative micro-volume measurement accessory. Unlike any other micro-volume spectrophotometer on the market the Genova Nano can not only be used for micro-volume measurements but also temperature sensitive reactions due to its flexibility to be used with any of the accessories of Jenway's 73 series including the standard volume electronic Peltier. \u003cbr\u003e\u003cbr\u003eThe Genova Nano micro-volume spectrophotometer measures small sample volumes as low as 0.5µl with a high degree of accuracy, reproducibility and speed. It has the ability to measure small sample volumes, conserves precious samples, reduces the need for dilutions and eliminates the requirement for cuvettes. Cleaning is quick and simple; wiping the read heads with a microfibre cloth removes all trace of the sample, allowing faster change over between samples and therefore increasing sample throughput. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"left\"\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/div\u003e\n\u003cdiv align=\"left\"\u003e• Micro-volume, life science and standard spectrophotometer in 1\u003cbr\u003e• Ideal for DNA, RNA and Protein measurements\u003cbr\u003e• Only 0.5µl sample volume required\u003cbr\u003e• Purity scan over entire wavelength range, 198 to 1000nm\u003cbr\u003e• Detects DNA concentrations as low as 2ng\/µl \u003cbr\u003e• Easy and quick to clean\u003cbr\u003e• Results are reproducible, accurate and easily obtained\u003cbr\u003e• Method and result saving to USB memory stick \u003cbr\u003e• 3 year warranty including Xenon lamp\u003cbr\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"left\"\u003e\u003cb\u003e\u003cbr\u003eTechnical Specification\u003c\/b\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003ctable align=\"left\" width=\"100%\" cellpadding=\"4\" cellspacing=\"0\" id=\"Table4\" class=\"productborder\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eParameter\u003c\/td\u003e\n\u003ctd align=\"left\"\u003eGenova Nano\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWavelength Range\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e198 to 1000nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e± 2nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSpectral Bandwidth \u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003ePath Length\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.2 or 0.5mm (auto-ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e- 15 to 125A (10mm equivalent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e± 2% at 260nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eAbsorbance Precision\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u0026lt; 0.005A between 0 and 1A (at 260nm and 0.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMaximum Concentration\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e6,000 ng\/µl (dsDNA) (at 0.2mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDetection Limit\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e2.0ng\/µl (dsDNA) (at 0.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMeasurement Time\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e\u0026lt; 6.5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMinimum sample Size\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e0.5µl (at 0.2mm),1.0µl (at 0.5mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eMaximum sample size\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e5.0µl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eDNA measurement modes\u003c\/td\u003e\n\u003ctd align=\"left\"\u003edsDNA, ssDNA, RNA, Oligonucleotides, 260\/ 280, 260\/ 230, Variable ratio\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eProtein measurement modes\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePierce 660, BCA, Bradford, Lowry, Biuret, Direct UV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSample Pedestal Material \u003c\/td\u003e\n\u003ctd align=\"left\"\u003eQuartz stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eLight Source\u003c\/td\u003e\n\u003ctd align=\"left\"\u003ePress to read Xenon lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eSize (w x d x h), mm\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e275 x 400 x 220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd align=\"left\"\u003eWeight, kg\u003c\/td\u003e\n\u003ctd align=\"left\"\u003e7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"left\"\u003eWhen the 10x10mm cuvette accessory is fitted the spectrophotometer conforms to the Genova Plus technical specification\u003c\/div\u003e"}