{"id":6588385132643,"title":"IKA C 1 Package 3\/12","handle":"ika-c-1-package-3-12","description":"\u003csection class=\"content-main container block-group is--fullscreen\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"content-main--inner\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"content--wrapper\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"ika-product-details\" data-mce-fragment=\"1\" itemscope=\"itemscope\" itemtype=\"http:\/\/schema.org\/Product\"\u003e\n\u003cdiv class=\"ika-product-detail-content\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"product-detail-page-section ika-content-container-832\" style=\"min-height: 26.625rem;\" data-mce-fragment=\"1\" data-mce-style=\"min-height: 26.625rem;\"\u003e\n\u003cdiv class=\"product_text\" data-mce-fragment=\"1\" itemprop=\"description\"\u003eThe C 1 static jacket oxygen bomb calorimeter provides a high degree of automation and has the smallest calorimeter footprint available. It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eWith the package 3\/12 including C 1.20 water heater it is possible to operate the C 1 with drinking-quality tap water in a temperature range of 5 °C to 25 °C (water temperature \u0026lt; 21°C: measuring mode 22°C\/ water temperature \u0026gt; 21 °C: measuring mode 30°C). A chiller is no longer required. The C 1.20 heater serves to maintain the correct temperature of the tap water, which must be connected to the heater at a maximum pressure of 6 bar\/0.6 MPa. C 25 pressure regulating gauge is recommended as an accessory if the pressure is higher or cannot be maintained. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eScope of delivery\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1 calorimeter\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1.12 combustion chamber\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1.20 water heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr data-mce-fragment=\"1\"\u003eThe scope of delivery includes all parts necessary to set up the unit. Additionally it includes wear parts and consumables for the first approximately 500 experiments including 25 calibrations. The catalytic activated, halogen resistant combustion chamber C 1.12 is specifically designed for the combustion of samples that contain halogens and sulfur ( \u0026gt; 3 % ). It is equipped with the C 5010.5 large crucible holder and C 6 large quartz crucible. \u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cb data-mce-fragment=\"1\"\u003eScope of delivery\u003c\/b\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1 S000\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1.12 Combustion chamber, halogen resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1.20 Heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"clear-footer\" style=\"margin-top: 50px;\" data-mce-fragment=\"1\" data-mce-style=\"margin-top: 50px;\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cfooter class=\"footer-main\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"container\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"footer--columns block-group\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"footer-menu\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/footer\u003e","published_at":"2021-06-08T16:27:49+12:00","created_at":"2021-06-08T16:27:48+12:00","vendor":"IKA","type":"Calorimeters","tags":["Category_Calorimetry","Manufacturer_IKA","Type_Calorimeters"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39416451399779,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"IKA C 1 Package 3\/12","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/C1Package3-12_1.jpg?v=1623126470"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C1Package3-12_1.jpg?v=1623126470","options":["Title"],"media":[{"alt":null,"id":20600240898147,"position":1,"preview_image":{"aspect_ratio":1.152,"height":868,"width":1000,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C1Package3-12_1.jpg?v=1623126470"},"aspect_ratio":1.152,"height":868,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/C1Package3-12_1.jpg?v=1623126470","width":1000}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003csection class=\"content-main container block-group is--fullscreen\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"content-main--inner\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"content--wrapper\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"ika-product-details\" data-mce-fragment=\"1\" itemscope=\"itemscope\" itemtype=\"http:\/\/schema.org\/Product\"\u003e\n\u003cdiv class=\"ika-product-detail-content\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"product-detail-page-section ika-content-container-832\" style=\"min-height: 26.625rem;\" data-mce-fragment=\"1\" data-mce-style=\"min-height: 26.625rem;\"\u003e\n\u003cdiv class=\"product_text\" data-mce-fragment=\"1\" itemprop=\"description\"\u003eThe C 1 static jacket oxygen bomb calorimeter provides a high degree of automation and has the smallest calorimeter footprint available. It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eWith the package 3\/12 including C 1.20 water heater it is possible to operate the C 1 with drinking-quality tap water in a temperature range of 5 °C to 25 °C (water temperature \u0026lt; 21°C: measuring mode 22°C\/ water temperature \u0026gt; 21 °C: measuring mode 30°C). A chiller is no longer required. The C 1.20 heater serves to maintain the correct temperature of the tap water, which must be connected to the heater at a maximum pressure of 6 bar\/0.6 MPa. C 25 pressure regulating gauge is recommended as an accessory if the pressure is higher or cannot be maintained. \u003cbr data-mce-fragment=\"1\"\u003e \u003cbr data-mce-fragment=\"1\"\u003eScope of delivery\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1 calorimeter\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1.12 combustion chamber\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1.20 water heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr data-mce-fragment=\"1\"\u003eThe scope of delivery includes all parts necessary to set up the unit. Additionally it includes wear parts and consumables for the first approximately 500 experiments including 25 calibrations. The catalytic activated, halogen resistant combustion chamber C 1.12 is specifically designed for the combustion of samples that contain halogens and sulfur ( \u0026gt; 3 % ). It is equipped with the C 5010.5 large crucible holder and C 6 large quartz crucible. \u003cbr data-mce-fragment=\"1\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e \u003cb data-mce-fragment=\"1\"\u003eScope of delivery\u003c\/b\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1 S000\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1.12 Combustion chamber, halogen resistant\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eC 1.20 Heater\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cbr data-mce-fragment=\"1\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv class=\"clear-footer\" style=\"margin-top: 50px;\" data-mce-fragment=\"1\" data-mce-style=\"margin-top: 50px;\"\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003cfooter class=\"footer-main\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"container\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"footer--columns block-group\" data-mce-fragment=\"1\"\u003e\n\u003cdiv class=\"footer-menu\" data-mce-fragment=\"1\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/footer\u003e"}

IKA C 1 Package 3/12

Product Description
The C 1 static jacket oxygen bomb calorimeter provides a high degree of automation and has the smallest calorimeter footprint available. It operates according to DIN 51900 and ISO 1928. The temperature readings are analyzed according to the classical isoperibol method of Regnault Pfaundler.

With the package 3/12 including C 1.20 water heater it is possible to operate the C 1 with drinking-quality tap water in a temperature range of 5 °C to 25 °C (water temperature < 21°C: measuring mode 22°C/ water temperature > 21 °C: measuring mode 30°C). A chiller is no longer required. The C 1.20 heater serves to maintain the correct temperature of the tap water, which must be connected to the heater at a maximum pressure of 6 bar/0.6 MPa. C 25 pressure regulating gauge is recommended as an accessory if the pressure is higher or cannot be maintained.

Scope of delivery
  • C 1 calorimeter
  • C 1.12 combustion chamber
  • C 1.20 water heater

The scope of delivery includes all parts necessary to set up the unit. Additionally it includes wear parts and consumables for the first approximately 500 experiments including 25 calibrations. The catalytic activated, halogen resistant combustion chamber C 1.12 is specifically designed for the combustion of samples that contain halogens and sulfur ( > 3 % ). It is equipped with the C 5010.5 large crucible holder and C 6 large quartz crucible.

Scope of delivery
  • C 1 S000
  • C 1.12 Combustion chamber, halogen resistant
  • C 1.20 Heater

This product is available upon request. Contact us for more information.

Liquid error (layout/theme line 139): Could not find asset snippets/beae_footer.liquid