Email info@acornsci.com for orders and inquiries.

{"id":1582195653,"title":"HANNA HII 98184-02 pH\/ORP\/ISE Waterproof Portable Meters","handle":"hi-98184-02","description":"\u003cp\u003eFeature Highlights\u003c\/p\u003e\n\u003cp\u003e• pH Calibration Check™\u003c\/p\u003e\n\u003cp\u003e• Electrode condition on display\u003c\/p\u003e\n\u003cp\u003e• Five point pH calibration with seven standard buffers\u003c\/p\u003e\n\u003cp\u003eand five custom buffers\u003c\/p\u003e\n\u003cp\u003e• Automatic logging and log on demand\u003c\/p\u003e\n\u003cp\u003e• Menu driven for ease of use\u003c\/p\u003e\n\u003cp\u003e• Soft-key extended functionality\u003c\/p\u003e\n\u003cp\u003e• Multiple language selection\u003c\/p\u003e\n\u003cp\u003e• Contextual help at the touch of a button\u003c\/p\u003e\n\u003cp\u003e• GLP features\u003c\/p\u003e\n\u003cp\u003e• USB\u003c\/p\u003e\n\u003cp\u003e• Backlit. graphic LCD and battery life on display\u003c\/p\u003e\n\u003cp\u003e• Waterproof and rugged casing\u003c\/p\u003e\n\u003cp\u003epH PORTABLE\u003c\/p\u003e\n\u003cp\u003eHI 98183 • HI 98184 • HI 98185\u003c\/p\u003e\n\u003cp\u003epH\/ORP\/ISE Waterproof Portable\u003c\/p\u003e\n\u003cp\u003eMeters\u003c\/p\u003e\n\u003cp\u003eHI 98183. HI 98184 and HI 98185 are waterproof. portable meters\u003c\/p\u003e\n\u003cp\u003edesigned for demanding applications. HI 98183 measures pH\/ORP\u003c\/p\u003e\n\u003cp\u003eand temperatuare while HI 98184 and HI 98185 also include\u003c\/p\u003e\n\u003cp\u003eISE measurement.\u003c\/p\u003e\n\u003cp\u003eChoose from 7 standard pH buffers and 5 custom pH buffers to\u003c\/p\u003e\n\u003cp\u003eobtain up to five point calibration and achieve high precision\u003c\/p\u003e\n\u003cp\u003ereadings with a pH accuracy of ±0.002 and up to ±0.001\u003c\/p\u003e\n\u003cp\u003epH resolution.\u003c\/p\u003e\n\u003cp\u003eHANNA's Calibration Check® maintains a history of past calibrations\u003c\/p\u003e\n\u003cp\u003eand monitors the pH electrode and buffers during subsequent\u003c\/p\u003e\n\u003cp\u003ecalibrations for any signs of wide calibration variances due to a dirty\u003c\/p\u003e\n\u003cp\u003eor broken electrode or contaminated pH buffers. In measurement\u003c\/p\u003e\n\u003cp\u003emode. the electrode's percent condition is continuously displayed.\u003c\/p\u003e\n\u003cp\u003eExchange out the pH probe for an ORP probe to obtain mV readings\u003c\/p\u003e\n\u003cp\u003ein the ±2000 mV range. HI 98184 and HI 98185 adds direct ion\u003c\/p\u003e\n\u003cp\u003econcentration readings for ISE's and the results are displayed in ppm.\u003c\/p\u003e\n\u003cp\u003eThe ion charge or nominal slope can be entered manually.\u003c\/p\u003e\n\u003cp\u003eHI 98185 adds auto recognition of 15 different ISE sensors and can\u003c\/p\u003e\n\u003cp\u003ebe calibrated in up to five points and 6 standard buffers (choice of\u003c\/p\u003e\n\u003cp\u003eunits). This meter allows an extensive choice of measurement units\u003c\/p\u003e\n\u003cp\u003e(ppm. ppt. g\/L. ppb. ug\/L. mg\/mL. M. mol\/L. mmol\/L. % w\/v. user)\u003c\/p\u003e\n\u003cp\u003eand has an expanded measuring range of 1.00 x 10-7 to 9.99 x 10-10.\u003c\/p\u003e\n\u003cp\u003ePress Auto-Hold while measuring and once stabilized. the current\u003c\/p\u003e\n\u003cp\u003ereading will remain displayed for your convenience in documenting.\u003c\/p\u003e\n\u003cp\u003eSwitching to log-on-demand mode allows users to record and save\u003c\/p\u003e\n\u003cp\u003eup to 200 samples (HI 98183) or 300 samples (HI 98184 and\u003c\/p\u003e\n\u003cp\u003eHI 98185). This data can later be transferred to a PC with the USB\u003c\/p\u003e\n\u003cp\u003econnection and HANNA's HI 92000 software. “Out Of Calibration\u003c\/p\u003e\n\u003cp\u003eRange Warning” can be engaged to keep the user informed of the\u003c\/p\u003e\n\u003cp\u003ecurrent calibration and helps to avoid taking measurements that are\u003c\/p\u003e\n\u003cp\u003eout of range.\u003c\/p\u003e\n\u003cp\u003eA backlit. graphic LCD provides easy to read resolution even in lowlit\u003c\/p\u003e\n\u003cp\u003eareas. A combination of dedicated and soft keys allows easy.\u003c\/p\u003e\n\u003cp\u003eintuitive operation in a choice of languages. Comprehensive GLP\u003c\/p\u003e\n\u003cp\u003edata are directly accessible by pressing the GLP key. Access the\u003c\/p\u003e\n\u003cp\u003econtextual Help Menu to obtain on-screen information and\u003c\/p\u003e\n\u003cp\u003eassistance about each feature at the touch of a button. Designed\u003c\/p\u003e\n\u003cp\u003efor field use. these instruments can be operated with one hand and\u003c\/p\u003e\n\u003cp\u003eare supplied in a rugged carrying case. With an extended battery\u003c\/p\u003e\n\u003cp\u003elife of up to 200 hours. users are assured long operation. The\u003c\/p\u003e\n\u003cp\u003einductive charger can either be plugged into a standard 115V\u003c\/p\u003e\n\u003cp\u003esocket with the included adapter or a 12 VDC source. such as a car's\u003c\/p\u003e\n\u003cp\u003e12 V accessory outlet.\u003c\/p\u003e\n\u003cp\u003eThese meters come equipped with the HI 72911B pH\/ temperature\u003c\/p\u003e\n\u003cp\u003eelectrode with rugged. titanium casing.\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS HI 98183 HI 98184 HI 98185\u003c\/p\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003cp\u003epH -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH\u003c\/p\u003e\n\u003cp\u003emV ±2000 mV\u003c\/p\u003e\n\u003cp\u003eISE — from 1.00 e-3 to 1.00 e5\u003c\/p\u003e\n\u003cp\u003econcentration\u003c\/p\u003e\n\u003cp\u003efrom 1.00 e-7 to 9.99 e10\u003c\/p\u003e\n\u003cp\u003econcentration\u003c\/p\u003e\n\u003cp\u003eTemperature -20.0 to 120.0 °C (-4.0 to 248.0°F)\u003c\/p\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003cp\u003epH 0.1; 0.01; 0.001 pH\u003c\/p\u003e\n\u003cp\u003emV 0.1 mV\u003c\/p\u003e\n\u003cp\u003eISE — 3 digits 0.01; 0.1; 1; 10 concentration\u003c\/p\u003e\n\u003cp\u003eTemperature 0.1°C (0.1°F)\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003cp\u003epH ±0.01; ±0.002 pH\u003c\/p\u003e\n\u003cp\u003emV ±0.2 mV\u003c\/p\u003e\n\u003cp\u003eISE — ±0.5% of reading (monovalent ions).\u003c\/p\u003e\n\u003cp\u003e±1% of reading (divalent ions)\u003c\/p\u003e\n\u003cp\u003eTemperature ±0.4°C (±0.8°F) (excluding probe error)\u003c\/p\u003e\n\u003cp\u003eCalibration\u003c\/p\u003e\n\u003cp\u003epH up to five point calibration. seven standard buffers available\u003c\/p\u003e\n\u003cp\u003e(1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45) + five custom buffers\u003c\/p\u003e\n\u003cp\u003eISE —\u003c\/p\u003e\n\u003cp\u003eup to two point calibration.\u003c\/p\u003e\n\u003cp\u003esix standard solutions\u003c\/p\u003e\n\u003cp\u003e(0.1. 1. 10. 100. 1000.\u003c\/p\u003e\n\u003cp\u003e10000 ppm)\u003c\/p\u003e\n\u003cp\u003eup to five point calibration.\u003c\/p\u003e\n\u003cp\u003esix standard solutions\u003c\/p\u003e\n\u003cp\u003e(0.1. 1. 10. 100. 1000.\u003c\/p\u003e\n\u003cp\u003e10000 ppm)\u003c\/p\u003e\n\u003cp\u003eSlope From 80 to 110%\u003c\/p\u003e\n\u003cp\u003eTemperature Compensation\u003c\/p\u003e\n\u003cp\u003e(pH) manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/p\u003e\n\u003cp\u003eProbe Hi 72911B titanium body. pH electrode with internal temperature sensor.\u003c\/p\u003e\n\u003cp\u003eBnC connector and 1 m (3.3’ cable)\u003c\/p\u003e\n\u003cp\u003eLogging log on demand 200\u003c\/p\u003e\n\u003cp\u003esamples (100 ea. range) log on demand 300 samples (100 each range)\u003c\/p\u003e\n\u003cp\u003ePC Connectivity opto-isolated UsB with optional Hi 92000 software\u003c\/p\u003e\n\u003cp\u003eInput Impedance 1012 ohms\u003c\/p\u003e\n\u003cp\u003eBattery Type \/ Life 1.2V AA rechargeable batteries (4) \/ approximately 200 hours\u003c\/p\u003e\n\u003cp\u003eof continuous use without backlight (50 hours with backlight)\u003c\/p\u003e\n\u003cp\u003eAuto-off user selectable: 5. 10. 30. 60 min or can be disabled\u003c\/p\u003e\n\u003cp\u003eEnvironment 0 to 50°C (32 to 122°F); RH 100%\u003c\/p\u003e\n\u003cp\u003eDimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)\u003c\/p\u003e\n\u003cp\u003eWeight 525 g (18.5 oz.)\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eORDERING INFORMATION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHI 98183-01 (115V). HI 98183-02 (230V).\u003c\/p\u003e\n\u003cp\u003eHI 98184-01 (115V). HI 98184-02 (230V) and\u003c\/p\u003e\n\u003cp\u003eHI 98185-01 (115V) and HI 98185-02 (230V) are\u003c\/p\u003e\n\u003cp\u003esupplied with HI 72911B pH electrode. HI 70004\u003c\/p\u003e\n\u003cp\u003epH 4.01 buffer solution sachet. HI 70007 pH 7.01\u003c\/p\u003e\n\u003cp\u003ebuffer solution sachet. rechargeable batteries.\u003c\/p\u003e\n\u003cp\u003eHI 710042 inductive battery charger with power\u003c\/p\u003e\n\u003cp\u003eadapter. instructions and hard carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRODES AND PROBES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombination pH electrodes with BNC connector\u003c\/p\u003e\n\u003cp\u003eand 1 m (3.3’) cable:\u003c\/p\u003e\n\u003cp\u003eHI 1043B Use: strong acids and bases.\u003c\/p\u003e\n\u003cp\u003eglass-body. double junction. refillable\u003c\/p\u003e\n\u003cp\u003eHI 1230B Use: general purpose. PEI body.\u003c\/p\u003e\n\u003cp\u003edouble junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 72911B Use: general purpose. titanium\u003c\/p\u003e\n\u003cp\u003ebody. double junction. gel-filled\u003c\/p\u003e\n\u003cp\u003ewith internal temperature sensor\u003c\/p\u003e\n\u003cp\u003eHI 3230B Use: For oxidizing reactions.\u003c\/p\u003e\n\u003cp\u003eplatinum tipped ORP probe. PEI\u003c\/p\u003e\n\u003cp\u003ebody. single junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 4430B Use: Strong oxidizing solutions\u003c\/p\u003e\n\u003cp\u003egold tipped ORP probe. PEI\u003c\/p\u003e\n\u003cp\u003ebody. single junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 7662 Temperature probe with\u003c\/p\u003e\n\u003cp\u003e1 m (3.3’) screened cable\u003c\/p\u003e\n\u003cp\u003eSOLUTIONS\u003c\/p\u003e\n\u003cp\u003eHI 5004L pH 4.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 5007L pH 7.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 5010L pH 10.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7061L Electrode cleaning solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 70300L Electrode storage solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7091L ORP reducing pretreatment solution.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7092L ORP oxidizing pretreatment solution.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7020L ORP test solution @200-275 mV.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7021L ORP test solution @240 mV. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7022L ORP test solution @470 mV. 500 mL\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eACCESSORIES\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHI 920013 USB cable for PC connection\u003c\/p\u003e\n\u003cp\u003eHI 92000 Windows® compatible software\u003c\/p\u003e","published_at":"2026-06-25T15:48:33+12:00","created_at":"2015-09-01T15:20:19+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters","Type_pH \u0026 ORP Meters"],"price":197220,"price_min":197220,"price_max":197220,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857347141,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI 98184-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HII 98184-02 pH\/ORP\/ISE Waterproof Portable Meters","public_title":null,"options":["Default Title"],"price":197220,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/HI98185_200_2015.jpeg?v=1443495998"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI98185_200_2015.jpeg?v=1443495998","options":["Title"],"media":[{"alt":"HANNA HII 98184-02 pH\/ORP\/ISE Waterproof Portable Meters - Acorn Scientific","id":21312274531,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI98185_200_2015.jpeg?v=1443495998"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI98185_200_2015.jpeg?v=1443495998","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eFeature Highlights\u003c\/p\u003e\n\u003cp\u003e• pH Calibration Check™\u003c\/p\u003e\n\u003cp\u003e• Electrode condition on display\u003c\/p\u003e\n\u003cp\u003e• Five point pH calibration with seven standard buffers\u003c\/p\u003e\n\u003cp\u003eand five custom buffers\u003c\/p\u003e\n\u003cp\u003e• Automatic logging and log on demand\u003c\/p\u003e\n\u003cp\u003e• Menu driven for ease of use\u003c\/p\u003e\n\u003cp\u003e• Soft-key extended functionality\u003c\/p\u003e\n\u003cp\u003e• Multiple language selection\u003c\/p\u003e\n\u003cp\u003e• Contextual help at the touch of a button\u003c\/p\u003e\n\u003cp\u003e• GLP features\u003c\/p\u003e\n\u003cp\u003e• USB\u003c\/p\u003e\n\u003cp\u003e• Backlit. graphic LCD and battery life on display\u003c\/p\u003e\n\u003cp\u003e• Waterproof and rugged casing\u003c\/p\u003e\n\u003cp\u003epH PORTABLE\u003c\/p\u003e\n\u003cp\u003eHI 98183 • HI 98184 • HI 98185\u003c\/p\u003e\n\u003cp\u003epH\/ORP\/ISE Waterproof Portable\u003c\/p\u003e\n\u003cp\u003eMeters\u003c\/p\u003e\n\u003cp\u003eHI 98183. HI 98184 and HI 98185 are waterproof. portable meters\u003c\/p\u003e\n\u003cp\u003edesigned for demanding applications. HI 98183 measures pH\/ORP\u003c\/p\u003e\n\u003cp\u003eand temperatuare while HI 98184 and HI 98185 also include\u003c\/p\u003e\n\u003cp\u003eISE measurement.\u003c\/p\u003e\n\u003cp\u003eChoose from 7 standard pH buffers and 5 custom pH buffers to\u003c\/p\u003e\n\u003cp\u003eobtain up to five point calibration and achieve high precision\u003c\/p\u003e\n\u003cp\u003ereadings with a pH accuracy of ±0.002 and up to ±0.001\u003c\/p\u003e\n\u003cp\u003epH resolution.\u003c\/p\u003e\n\u003cp\u003eHANNA's Calibration Check® maintains a history of past calibrations\u003c\/p\u003e\n\u003cp\u003eand monitors the pH electrode and buffers during subsequent\u003c\/p\u003e\n\u003cp\u003ecalibrations for any signs of wide calibration variances due to a dirty\u003c\/p\u003e\n\u003cp\u003eor broken electrode or contaminated pH buffers. In measurement\u003c\/p\u003e\n\u003cp\u003emode. the electrode's percent condition is continuously displayed.\u003c\/p\u003e\n\u003cp\u003eExchange out the pH probe for an ORP probe to obtain mV readings\u003c\/p\u003e\n\u003cp\u003ein the ±2000 mV range. HI 98184 and HI 98185 adds direct ion\u003c\/p\u003e\n\u003cp\u003econcentration readings for ISE's and the results are displayed in ppm.\u003c\/p\u003e\n\u003cp\u003eThe ion charge or nominal slope can be entered manually.\u003c\/p\u003e\n\u003cp\u003eHI 98185 adds auto recognition of 15 different ISE sensors and can\u003c\/p\u003e\n\u003cp\u003ebe calibrated in up to five points and 6 standard buffers (choice of\u003c\/p\u003e\n\u003cp\u003eunits). This meter allows an extensive choice of measurement units\u003c\/p\u003e\n\u003cp\u003e(ppm. ppt. g\/L. ppb. ug\/L. mg\/mL. M. mol\/L. mmol\/L. % w\/v. user)\u003c\/p\u003e\n\u003cp\u003eand has an expanded measuring range of 1.00 x 10-7 to 9.99 x 10-10.\u003c\/p\u003e\n\u003cp\u003ePress Auto-Hold while measuring and once stabilized. the current\u003c\/p\u003e\n\u003cp\u003ereading will remain displayed for your convenience in documenting.\u003c\/p\u003e\n\u003cp\u003eSwitching to log-on-demand mode allows users to record and save\u003c\/p\u003e\n\u003cp\u003eup to 200 samples (HI 98183) or 300 samples (HI 98184 and\u003c\/p\u003e\n\u003cp\u003eHI 98185). This data can later be transferred to a PC with the USB\u003c\/p\u003e\n\u003cp\u003econnection and HANNA's HI 92000 software. “Out Of Calibration\u003c\/p\u003e\n\u003cp\u003eRange Warning” can be engaged to keep the user informed of the\u003c\/p\u003e\n\u003cp\u003ecurrent calibration and helps to avoid taking measurements that are\u003c\/p\u003e\n\u003cp\u003eout of range.\u003c\/p\u003e\n\u003cp\u003eA backlit. graphic LCD provides easy to read resolution even in lowlit\u003c\/p\u003e\n\u003cp\u003eareas. A combination of dedicated and soft keys allows easy.\u003c\/p\u003e\n\u003cp\u003eintuitive operation in a choice of languages. Comprehensive GLP\u003c\/p\u003e\n\u003cp\u003edata are directly accessible by pressing the GLP key. Access the\u003c\/p\u003e\n\u003cp\u003econtextual Help Menu to obtain on-screen information and\u003c\/p\u003e\n\u003cp\u003eassistance about each feature at the touch of a button. Designed\u003c\/p\u003e\n\u003cp\u003efor field use. these instruments can be operated with one hand and\u003c\/p\u003e\n\u003cp\u003eare supplied in a rugged carrying case. With an extended battery\u003c\/p\u003e\n\u003cp\u003elife of up to 200 hours. users are assured long operation. The\u003c\/p\u003e\n\u003cp\u003einductive charger can either be plugged into a standard 115V\u003c\/p\u003e\n\u003cp\u003esocket with the included adapter or a 12 VDC source. such as a car's\u003c\/p\u003e\n\u003cp\u003e12 V accessory outlet.\u003c\/p\u003e\n\u003cp\u003eThese meters come equipped with the HI 72911B pH\/ temperature\u003c\/p\u003e\n\u003cp\u003eelectrode with rugged. titanium casing.\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS HI 98183 HI 98184 HI 98185\u003c\/p\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003cp\u003epH -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH\u003c\/p\u003e\n\u003cp\u003emV ±2000 mV\u003c\/p\u003e\n\u003cp\u003eISE — from 1.00 e-3 to 1.00 e5\u003c\/p\u003e\n\u003cp\u003econcentration\u003c\/p\u003e\n\u003cp\u003efrom 1.00 e-7 to 9.99 e10\u003c\/p\u003e\n\u003cp\u003econcentration\u003c\/p\u003e\n\u003cp\u003eTemperature -20.0 to 120.0 °C (-4.0 to 248.0°F)\u003c\/p\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003cp\u003epH 0.1; 0.01; 0.001 pH\u003c\/p\u003e\n\u003cp\u003emV 0.1 mV\u003c\/p\u003e\n\u003cp\u003eISE — 3 digits 0.01; 0.1; 1; 10 concentration\u003c\/p\u003e\n\u003cp\u003eTemperature 0.1°C (0.1°F)\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003cp\u003epH ±0.01; ±0.002 pH\u003c\/p\u003e\n\u003cp\u003emV ±0.2 mV\u003c\/p\u003e\n\u003cp\u003eISE — ±0.5% of reading (monovalent ions).\u003c\/p\u003e\n\u003cp\u003e±1% of reading (divalent ions)\u003c\/p\u003e\n\u003cp\u003eTemperature ±0.4°C (±0.8°F) (excluding probe error)\u003c\/p\u003e\n\u003cp\u003eCalibration\u003c\/p\u003e\n\u003cp\u003epH up to five point calibration. seven standard buffers available\u003c\/p\u003e\n\u003cp\u003e(1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45) + five custom buffers\u003c\/p\u003e\n\u003cp\u003eISE —\u003c\/p\u003e\n\u003cp\u003eup to two point calibration.\u003c\/p\u003e\n\u003cp\u003esix standard solutions\u003c\/p\u003e\n\u003cp\u003e(0.1. 1. 10. 100. 1000.\u003c\/p\u003e\n\u003cp\u003e10000 ppm)\u003c\/p\u003e\n\u003cp\u003eup to five point calibration.\u003c\/p\u003e\n\u003cp\u003esix standard solutions\u003c\/p\u003e\n\u003cp\u003e(0.1. 1. 10. 100. 1000.\u003c\/p\u003e\n\u003cp\u003e10000 ppm)\u003c\/p\u003e\n\u003cp\u003eSlope From 80 to 110%\u003c\/p\u003e\n\u003cp\u003eTemperature Compensation\u003c\/p\u003e\n\u003cp\u003e(pH) manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/p\u003e\n\u003cp\u003eProbe Hi 72911B titanium body. pH electrode with internal temperature sensor.\u003c\/p\u003e\n\u003cp\u003eBnC connector and 1 m (3.3’ cable)\u003c\/p\u003e\n\u003cp\u003eLogging log on demand 200\u003c\/p\u003e\n\u003cp\u003esamples (100 ea. range) log on demand 300 samples (100 each range)\u003c\/p\u003e\n\u003cp\u003ePC Connectivity opto-isolated UsB with optional Hi 92000 software\u003c\/p\u003e\n\u003cp\u003eInput Impedance 1012 ohms\u003c\/p\u003e\n\u003cp\u003eBattery Type \/ Life 1.2V AA rechargeable batteries (4) \/ approximately 200 hours\u003c\/p\u003e\n\u003cp\u003eof continuous use without backlight (50 hours with backlight)\u003c\/p\u003e\n\u003cp\u003eAuto-off user selectable: 5. 10. 30. 60 min or can be disabled\u003c\/p\u003e\n\u003cp\u003eEnvironment 0 to 50°C (32 to 122°F); RH 100%\u003c\/p\u003e\n\u003cp\u003eDimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)\u003c\/p\u003e\n\u003cp\u003eWeight 525 g (18.5 oz.)\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eORDERING INFORMATION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHI 98183-01 (115V). HI 98183-02 (230V).\u003c\/p\u003e\n\u003cp\u003eHI 98184-01 (115V). HI 98184-02 (230V) and\u003c\/p\u003e\n\u003cp\u003eHI 98185-01 (115V) and HI 98185-02 (230V) are\u003c\/p\u003e\n\u003cp\u003esupplied with HI 72911B pH electrode. HI 70004\u003c\/p\u003e\n\u003cp\u003epH 4.01 buffer solution sachet. HI 70007 pH 7.01\u003c\/p\u003e\n\u003cp\u003ebuffer solution sachet. rechargeable batteries.\u003c\/p\u003e\n\u003cp\u003eHI 710042 inductive battery charger with power\u003c\/p\u003e\n\u003cp\u003eadapter. instructions and hard carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRODES AND PROBES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombination pH electrodes with BNC connector\u003c\/p\u003e\n\u003cp\u003eand 1 m (3.3’) cable:\u003c\/p\u003e\n\u003cp\u003eHI 1043B Use: strong acids and bases.\u003c\/p\u003e\n\u003cp\u003eglass-body. double junction. refillable\u003c\/p\u003e\n\u003cp\u003eHI 1230B Use: general purpose. PEI body.\u003c\/p\u003e\n\u003cp\u003edouble junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 72911B Use: general purpose. titanium\u003c\/p\u003e\n\u003cp\u003ebody. double junction. gel-filled\u003c\/p\u003e\n\u003cp\u003ewith internal temperature sensor\u003c\/p\u003e\n\u003cp\u003eHI 3230B Use: For oxidizing reactions.\u003c\/p\u003e\n\u003cp\u003eplatinum tipped ORP probe. PEI\u003c\/p\u003e\n\u003cp\u003ebody. single junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 4430B Use: Strong oxidizing solutions\u003c\/p\u003e\n\u003cp\u003egold tipped ORP probe. PEI\u003c\/p\u003e\n\u003cp\u003ebody. single junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 7662 Temperature probe with\u003c\/p\u003e\n\u003cp\u003e1 m (3.3’) screened cable\u003c\/p\u003e\n\u003cp\u003eSOLUTIONS\u003c\/p\u003e\n\u003cp\u003eHI 5004L pH 4.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 5007L pH 7.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 5010L pH 10.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7061L Electrode cleaning solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 70300L Electrode storage solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7091L ORP reducing pretreatment solution.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7092L ORP oxidizing pretreatment solution.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7020L ORP test solution @200-275 mV.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7021L ORP test solution @240 mV. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7022L ORP test solution @470 mV. 500 mL\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eACCESSORIES\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHI 920013 USB cable for PC connection\u003c\/p\u003e\n\u003cp\u003eHI 92000 Windows® compatible software\u003c\/p\u003e"}

HANNA HII 98184-02 pH/ORP/ISE Waterproof Portable Meters

Product Description

Feature Highlights

• pH Calibration Check™

• Electrode condition on display

• Five point pH calibration with seven standard buffers

and five custom buffers

• Automatic logging and log on demand

• Menu driven for ease of use

• Soft-key extended functionality

• Multiple language selection

• Contextual help at the touch of a button

• GLP features

• USB

• Backlit. graphic LCD and battery life on display

• Waterproof and rugged casing

pH PORTABLE

HI 98183 • HI 98184 • HI 98185

pH/ORP/ISE Waterproof Portable

Meters

HI 98183. HI 98184 and HI 98185 are waterproof. portable meters

designed for demanding applications. HI 98183 measures pH/ORP

and temperatuare while HI 98184 and HI 98185 also include

ISE measurement.

Choose from 7 standard pH buffers and 5 custom pH buffers to

obtain up to five point calibration and achieve high precision

readings with a pH accuracy of ±0.002 and up to ±0.001

pH resolution.

HANNA's Calibration Check® maintains a history of past calibrations

and monitors the pH electrode and buffers during subsequent

calibrations for any signs of wide calibration variances due to a dirty

or broken electrode or contaminated pH buffers. In measurement

mode. the electrode's percent condition is continuously displayed.

Exchange out the pH probe for an ORP probe to obtain mV readings

in the ±2000 mV range. HI 98184 and HI 98185 adds direct ion

concentration readings for ISE's and the results are displayed in ppm.

The ion charge or nominal slope can be entered manually.

HI 98185 adds auto recognition of 15 different ISE sensors and can

be calibrated in up to five points and 6 standard buffers (choice of

units). This meter allows an extensive choice of measurement units

(ppm. ppt. g/L. ppb. ug/L. mg/mL. M. mol/L. mmol/L. % w/v. user)

and has an expanded measuring range of 1.00 x 10-7 to 9.99 x 10-10.

Press Auto-Hold while measuring and once stabilized. the current

reading will remain displayed for your convenience in documenting.

Switching to log-on-demand mode allows users to record and save

up to 200 samples (HI 98183) or 300 samples (HI 98184 and

HI 98185). This data can later be transferred to a PC with the USB

connection and HANNA's HI 92000 software. “Out Of Calibration

Range Warning” can be engaged to keep the user informed of the

current calibration and helps to avoid taking measurements that are

out of range.

A backlit. graphic LCD provides easy to read resolution even in lowlit

areas. A combination of dedicated and soft keys allows easy.

intuitive operation in a choice of languages. Comprehensive GLP

data are directly accessible by pressing the GLP key. Access the

contextual Help Menu to obtain on-screen information and

assistance about each feature at the touch of a button. Designed

for field use. these instruments can be operated with one hand and

are supplied in a rugged carrying case. With an extended battery

life of up to 200 hours. users are assured long operation. The

inductive charger can either be plugged into a standard 115V

socket with the included adapter or a 12 VDC source. such as a car's

12 V accessory outlet.

These meters come equipped with the HI 72911B pH/ temperature

electrode with rugged. titanium casing.

SPECIFICATIONS HI 98183 HI 98184 HI 98185

Range

pH -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH

mV ±2000 mV

ISE — from 1.00 e-3 to 1.00 e5

concentration

from 1.00 e-7 to 9.99 e10

concentration

Temperature -20.0 to 120.0 °C (-4.0 to 248.0°F)

Resolution

pH 0.1; 0.01; 0.001 pH

mV 0.1 mV

ISE — 3 digits 0.01; 0.1; 1; 10 concentration

Temperature 0.1°C (0.1°F)

Accuracy

pH ±0.01; ±0.002 pH

mV ±0.2 mV

ISE — ±0.5% of reading (monovalent ions).

±1% of reading (divalent ions)

Temperature ±0.4°C (±0.8°F) (excluding probe error)

Calibration

pH up to five point calibration. seven standard buffers available

(1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45) + five custom buffers

ISE —

up to two point calibration.

six standard solutions

(0.1. 1. 10. 100. 1000.

10000 ppm)

up to five point calibration.

six standard solutions

(0.1. 1. 10. 100. 1000.

10000 ppm)

Slope From 80 to 110%

Temperature Compensation

(pH) manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)

Probe Hi 72911B titanium body. pH electrode with internal temperature sensor.

BnC connector and 1 m (3.3’ cable)

Logging log on demand 200

samples (100 ea. range) log on demand 300 samples (100 each range)

PC Connectivity opto-isolated UsB with optional Hi 92000 software

Input Impedance 1012 ohms

Battery Type / Life 1.2V AA rechargeable batteries (4) / approximately 200 hours

of continuous use without backlight (50 hours with backlight)

Auto-off user selectable: 5. 10. 30. 60 min or can be disabled

Environment 0 to 50°C (32 to 122°F); RH 100%

Dimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)

Weight 525 g (18.5 oz.)

ORDERING INFORMATION

HI 98183-01 (115V). HI 98183-02 (230V).

HI 98184-01 (115V). HI 98184-02 (230V) and

HI 98185-01 (115V) and HI 98185-02 (230V) are

supplied with HI 72911B pH electrode. HI 70004

pH 4.01 buffer solution sachet. HI 70007 pH 7.01

buffer solution sachet. rechargeable batteries.

HI 710042 inductive battery charger with power

adapter. instructions and hard carrying case.

ELECTRODES AND PROBES

Combination pH electrodes with BNC connector

and 1 m (3.3’) cable:

HI 1043B Use: strong acids and bases.

glass-body. double junction. refillable

HI 1230B Use: general purpose. PEI body.

double junction. gel-filled

HI 72911B Use: general purpose. titanium

body. double junction. gel-filled

with internal temperature sensor

HI 3230B Use: For oxidizing reactions.

platinum tipped ORP probe. PEI

body. single junction. gel-filled

HI 4430B Use: Strong oxidizing solutions

gold tipped ORP probe. PEI

body. single junction. gel-filled

HI 7662 Temperature probe with

1 m (3.3’) screened cable

SOLUTIONS

HI 5004L pH 4.01 buffer solution. 500 mL

HI 5007L pH 7.01 buffer solution. 500 mL

HI 5010L pH 10.01 buffer solution. 500 mL

HI 7061L Electrode cleaning solution. 500 mL

HI 70300L Electrode storage solution. 500 mL

HI 7091L ORP reducing pretreatment solution.

500 mL

HI 7092L ORP oxidizing pretreatment solution.

500 mL

HI 7020L ORP test solution @200-275 mV.

500 mL

HI 7021L ORP test solution @240 mV. 500 mL

HI 7022L ORP test solution @470 mV. 500 mL

ACCESSORIES

HI 920013 USB cable for PC connection

HI 92000 Windows® compatible software

This product is available upon request. Contact us for more information.