{"id":1582195653,"title":"HANNA HII 98184-02 pH\/ORP\/ISE Waterproof Portable Meters","handle":"hi-98184-02","description":"\u003cp\u003eFeature Highlights\u003c\/p\u003e\n\u003cp\u003e• pH Calibration Check™\u003c\/p\u003e\n\u003cp\u003e• Electrode condition on display\u003c\/p\u003e\n\u003cp\u003e• Five point pH calibration with seven standard buffers\u003c\/p\u003e\n\u003cp\u003eand five custom buffers\u003c\/p\u003e\n\u003cp\u003e• Automatic logging and log on demand\u003c\/p\u003e\n\u003cp\u003e• Menu driven for ease of use\u003c\/p\u003e\n\u003cp\u003e• Soft-key extended functionality\u003c\/p\u003e\n\u003cp\u003e• Multiple language selection\u003c\/p\u003e\n\u003cp\u003e• Contextual help at the touch of a button\u003c\/p\u003e\n\u003cp\u003e• GLP features\u003c\/p\u003e\n\u003cp\u003e• USB\u003c\/p\u003e\n\u003cp\u003e• Backlit. graphic LCD and battery life on display\u003c\/p\u003e\n\u003cp\u003e• Waterproof and rugged casing\u003c\/p\u003e\n\u003cp\u003epH PORTABLE\u003c\/p\u003e\n\u003cp\u003eHI 98183 • HI 98184 • HI 98185\u003c\/p\u003e\n\u003cp\u003epH\/ORP\/ISE Waterproof Portable\u003c\/p\u003e\n\u003cp\u003eMeters\u003c\/p\u003e\n\u003cp\u003eHI 98183. HI 98184 and HI 98185 are waterproof. portable meters\u003c\/p\u003e\n\u003cp\u003edesigned for demanding applications. HI 98183 measures pH\/ORP\u003c\/p\u003e\n\u003cp\u003eand temperatuare while HI 98184 and HI 98185 also include\u003c\/p\u003e\n\u003cp\u003eISE measurement.\u003c\/p\u003e\n\u003cp\u003eChoose from 7 standard pH buffers and 5 custom pH buffers to\u003c\/p\u003e\n\u003cp\u003eobtain up to five point calibration and achieve high precision\u003c\/p\u003e\n\u003cp\u003ereadings with a pH accuracy of ±0.002 and up to ±0.001\u003c\/p\u003e\n\u003cp\u003epH resolution.\u003c\/p\u003e\n\u003cp\u003eHANNA's Calibration Check® maintains a history of past calibrations\u003c\/p\u003e\n\u003cp\u003eand monitors the pH electrode and buffers during subsequent\u003c\/p\u003e\n\u003cp\u003ecalibrations for any signs of wide calibration variances due to a dirty\u003c\/p\u003e\n\u003cp\u003eor broken electrode or contaminated pH buffers. In measurement\u003c\/p\u003e\n\u003cp\u003emode. the electrode's percent condition is continuously displayed.\u003c\/p\u003e\n\u003cp\u003eExchange out the pH probe for an ORP probe to obtain mV readings\u003c\/p\u003e\n\u003cp\u003ein the ±2000 mV range. HI 98184 and HI 98185 adds direct ion\u003c\/p\u003e\n\u003cp\u003econcentration readings for ISE's and the results are displayed in ppm.\u003c\/p\u003e\n\u003cp\u003eThe ion charge or nominal slope can be entered manually.\u003c\/p\u003e\n\u003cp\u003eHI 98185 adds auto recognition of 15 different ISE sensors and can\u003c\/p\u003e\n\u003cp\u003ebe calibrated in up to five points and 6 standard buffers (choice of\u003c\/p\u003e\n\u003cp\u003eunits). This meter allows an extensive choice of measurement units\u003c\/p\u003e\n\u003cp\u003e(ppm. ppt. g\/L. ppb. ug\/L. mg\/mL. M. mol\/L. mmol\/L. % w\/v. user)\u003c\/p\u003e\n\u003cp\u003eand has an expanded measuring range of 1.00 x 10-7 to 9.99 x 10-10.\u003c\/p\u003e\n\u003cp\u003ePress Auto-Hold while measuring and once stabilized. the current\u003c\/p\u003e\n\u003cp\u003ereading will remain displayed for your convenience in documenting.\u003c\/p\u003e\n\u003cp\u003eSwitching to log-on-demand mode allows users to record and save\u003c\/p\u003e\n\u003cp\u003eup to 200 samples (HI 98183) or 300 samples (HI 98184 and\u003c\/p\u003e\n\u003cp\u003eHI 98185). This data can later be transferred to a PC with the USB\u003c\/p\u003e\n\u003cp\u003econnection and HANNA's HI 92000 software. “Out Of Calibration\u003c\/p\u003e\n\u003cp\u003eRange Warning” can be engaged to keep the user informed of the\u003c\/p\u003e\n\u003cp\u003ecurrent calibration and helps to avoid taking measurements that are\u003c\/p\u003e\n\u003cp\u003eout of range.\u003c\/p\u003e\n\u003cp\u003eA backlit. graphic LCD provides easy to read resolution even in lowlit\u003c\/p\u003e\n\u003cp\u003eareas. A combination of dedicated and soft keys allows easy.\u003c\/p\u003e\n\u003cp\u003eintuitive operation in a choice of languages. Comprehensive GLP\u003c\/p\u003e\n\u003cp\u003edata are directly accessible by pressing the GLP key. Access the\u003c\/p\u003e\n\u003cp\u003econtextual Help Menu to obtain on-screen information and\u003c\/p\u003e\n\u003cp\u003eassistance about each feature at the touch of a button. Designed\u003c\/p\u003e\n\u003cp\u003efor field use. these instruments can be operated with one hand and\u003c\/p\u003e\n\u003cp\u003eare supplied in a rugged carrying case. With an extended battery\u003c\/p\u003e\n\u003cp\u003elife of up to 200 hours. users are assured long operation. The\u003c\/p\u003e\n\u003cp\u003einductive charger can either be plugged into a standard 115V\u003c\/p\u003e\n\u003cp\u003esocket with the included adapter or a 12 VDC source. such as a car's\u003c\/p\u003e\n\u003cp\u003e12 V accessory outlet.\u003c\/p\u003e\n\u003cp\u003eThese meters come equipped with the HI 72911B pH\/ temperature\u003c\/p\u003e\n\u003cp\u003eelectrode with rugged. titanium casing.\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS HI 98183 HI 98184 HI 98185\u003c\/p\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003cp\u003epH -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH\u003c\/p\u003e\n\u003cp\u003emV ±2000 mV\u003c\/p\u003e\n\u003cp\u003eISE — from 1.00 e-3 to 1.00 e5\u003c\/p\u003e\n\u003cp\u003econcentration\u003c\/p\u003e\n\u003cp\u003efrom 1.00 e-7 to 9.99 e10\u003c\/p\u003e\n\u003cp\u003econcentration\u003c\/p\u003e\n\u003cp\u003eTemperature -20.0 to 120.0 °C (-4.0 to 248.0°F)\u003c\/p\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003cp\u003epH 0.1; 0.01; 0.001 pH\u003c\/p\u003e\n\u003cp\u003emV 0.1 mV\u003c\/p\u003e\n\u003cp\u003eISE — 3 digits 0.01; 0.1; 1; 10 concentration\u003c\/p\u003e\n\u003cp\u003eTemperature 0.1°C (0.1°F)\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003cp\u003epH ±0.01; ±0.002 pH\u003c\/p\u003e\n\u003cp\u003emV ±0.2 mV\u003c\/p\u003e\n\u003cp\u003eISE — ±0.5% of reading (monovalent ions).\u003c\/p\u003e\n\u003cp\u003e±1% of reading (divalent ions)\u003c\/p\u003e\n\u003cp\u003eTemperature ±0.4°C (±0.8°F) (excluding probe error)\u003c\/p\u003e\n\u003cp\u003eCalibration\u003c\/p\u003e\n\u003cp\u003epH up to five point calibration. seven standard buffers available\u003c\/p\u003e\n\u003cp\u003e(1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45) + five custom buffers\u003c\/p\u003e\n\u003cp\u003eISE —\u003c\/p\u003e\n\u003cp\u003eup to two point calibration.\u003c\/p\u003e\n\u003cp\u003esix standard solutions\u003c\/p\u003e\n\u003cp\u003e(0.1. 1. 10. 100. 1000.\u003c\/p\u003e\n\u003cp\u003e10000 ppm)\u003c\/p\u003e\n\u003cp\u003eup to five point calibration.\u003c\/p\u003e\n\u003cp\u003esix standard solutions\u003c\/p\u003e\n\u003cp\u003e(0.1. 1. 10. 100. 1000.\u003c\/p\u003e\n\u003cp\u003e10000 ppm)\u003c\/p\u003e\n\u003cp\u003eSlope From 80 to 110%\u003c\/p\u003e\n\u003cp\u003eTemperature Compensation\u003c\/p\u003e\n\u003cp\u003e(pH) manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/p\u003e\n\u003cp\u003eProbe Hi 72911B titanium body. pH electrode with internal temperature sensor.\u003c\/p\u003e\n\u003cp\u003eBnC connector and 1 m (3.3’ cable)\u003c\/p\u003e\n\u003cp\u003eLogging log on demand 200\u003c\/p\u003e\n\u003cp\u003esamples (100 ea. range) log on demand 300 samples (100 each range)\u003c\/p\u003e\n\u003cp\u003ePC Connectivity opto-isolated UsB with optional Hi 92000 software\u003c\/p\u003e\n\u003cp\u003eInput Impedance 1012 ohms\u003c\/p\u003e\n\u003cp\u003eBattery Type \/ Life 1.2V AA rechargeable batteries (4) \/ approximately 200 hours\u003c\/p\u003e\n\u003cp\u003eof continuous use without backlight (50 hours with backlight)\u003c\/p\u003e\n\u003cp\u003eAuto-off user selectable: 5. 10. 30. 60 min or can be disabled\u003c\/p\u003e\n\u003cp\u003eEnvironment 0 to 50°C (32 to 122°F); RH 100%\u003c\/p\u003e\n\u003cp\u003eDimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)\u003c\/p\u003e\n\u003cp\u003eWeight 525 g (18.5 oz.)\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eORDERING INFORMATION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHI 98183-01 (115V). HI 98183-02 (230V).\u003c\/p\u003e\n\u003cp\u003eHI 98184-01 (115V). HI 98184-02 (230V) and\u003c\/p\u003e\n\u003cp\u003eHI 98185-01 (115V) and HI 98185-02 (230V) are\u003c\/p\u003e\n\u003cp\u003esupplied with HI 72911B pH electrode. HI 70004\u003c\/p\u003e\n\u003cp\u003epH 4.01 buffer solution sachet. HI 70007 pH 7.01\u003c\/p\u003e\n\u003cp\u003ebuffer solution sachet. rechargeable batteries.\u003c\/p\u003e\n\u003cp\u003eHI 710042 inductive battery charger with power\u003c\/p\u003e\n\u003cp\u003eadapter. instructions and hard carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRODES AND PROBES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombination pH electrodes with BNC connector\u003c\/p\u003e\n\u003cp\u003eand 1 m (3.3’) cable:\u003c\/p\u003e\n\u003cp\u003eHI 1043B Use: strong acids and bases.\u003c\/p\u003e\n\u003cp\u003eglass-body. double junction. refillable\u003c\/p\u003e\n\u003cp\u003eHI 1230B Use: general purpose. PEI body.\u003c\/p\u003e\n\u003cp\u003edouble junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 72911B Use: general purpose. titanium\u003c\/p\u003e\n\u003cp\u003ebody. double junction. gel-filled\u003c\/p\u003e\n\u003cp\u003ewith internal temperature sensor\u003c\/p\u003e\n\u003cp\u003eHI 3230B Use: For oxidizing reactions.\u003c\/p\u003e\n\u003cp\u003eplatinum tipped ORP probe. PEI\u003c\/p\u003e\n\u003cp\u003ebody. single junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 4430B Use: Strong oxidizing solutions\u003c\/p\u003e\n\u003cp\u003egold tipped ORP probe. PEI\u003c\/p\u003e\n\u003cp\u003ebody. single junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 7662 Temperature probe with\u003c\/p\u003e\n\u003cp\u003e1 m (3.3’) screened cable\u003c\/p\u003e\n\u003cp\u003eSOLUTIONS\u003c\/p\u003e\n\u003cp\u003eHI 5004L pH 4.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 5007L pH 7.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 5010L pH 10.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7061L Electrode cleaning solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 70300L Electrode storage solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7091L ORP reducing pretreatment solution.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7092L ORP oxidizing pretreatment solution.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7020L ORP test solution @200-275 mV.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7021L ORP test solution @240 mV. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7022L ORP test solution @470 mV. 500 mL\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eACCESSORIES\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHI 920013 USB cable for PC connection\u003c\/p\u003e\n\u003cp\u003eHI 92000 Windows® compatible software\u003c\/p\u003e","published_at":"2026-06-25T15:48:33+12:00","created_at":"2015-09-01T15:20:19+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Conductivity\/TDS Meters","Type_pH \u0026 ORP Meters"],"price":197220,"price_min":197220,"price_max":197220,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857347141,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI 98184-02","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HII 98184-02 pH\/ORP\/ISE Waterproof Portable Meters","public_title":null,"options":["Default Title"],"price":197220,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/HI98185_200_2015.jpeg?v=1443495998"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI98185_200_2015.jpeg?v=1443495998","options":["Title"],"media":[{"alt":"HANNA HII 98184-02 pH\/ORP\/ISE Waterproof Portable Meters - Acorn Scientific","id":21312274531,"position":1,"preview_image":{"aspect_ratio":1.0,"height":200,"width":200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI98185_200_2015.jpeg?v=1443495998"},"aspect_ratio":1.0,"height":200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/HI98185_200_2015.jpeg?v=1443495998","width":200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003eFeature Highlights\u003c\/p\u003e\n\u003cp\u003e• pH Calibration Check™\u003c\/p\u003e\n\u003cp\u003e• Electrode condition on display\u003c\/p\u003e\n\u003cp\u003e• Five point pH calibration with seven standard buffers\u003c\/p\u003e\n\u003cp\u003eand five custom buffers\u003c\/p\u003e\n\u003cp\u003e• Automatic logging and log on demand\u003c\/p\u003e\n\u003cp\u003e• Menu driven for ease of use\u003c\/p\u003e\n\u003cp\u003e• Soft-key extended functionality\u003c\/p\u003e\n\u003cp\u003e• Multiple language selection\u003c\/p\u003e\n\u003cp\u003e• Contextual help at the touch of a button\u003c\/p\u003e\n\u003cp\u003e• GLP features\u003c\/p\u003e\n\u003cp\u003e• USB\u003c\/p\u003e\n\u003cp\u003e• Backlit. graphic LCD and battery life on display\u003c\/p\u003e\n\u003cp\u003e• Waterproof and rugged casing\u003c\/p\u003e\n\u003cp\u003epH PORTABLE\u003c\/p\u003e\n\u003cp\u003eHI 98183 • HI 98184 • HI 98185\u003c\/p\u003e\n\u003cp\u003epH\/ORP\/ISE Waterproof Portable\u003c\/p\u003e\n\u003cp\u003eMeters\u003c\/p\u003e\n\u003cp\u003eHI 98183. HI 98184 and HI 98185 are waterproof. portable meters\u003c\/p\u003e\n\u003cp\u003edesigned for demanding applications. HI 98183 measures pH\/ORP\u003c\/p\u003e\n\u003cp\u003eand temperatuare while HI 98184 and HI 98185 also include\u003c\/p\u003e\n\u003cp\u003eISE measurement.\u003c\/p\u003e\n\u003cp\u003eChoose from 7 standard pH buffers and 5 custom pH buffers to\u003c\/p\u003e\n\u003cp\u003eobtain up to five point calibration and achieve high precision\u003c\/p\u003e\n\u003cp\u003ereadings with a pH accuracy of ±0.002 and up to ±0.001\u003c\/p\u003e\n\u003cp\u003epH resolution.\u003c\/p\u003e\n\u003cp\u003eHANNA's Calibration Check® maintains a history of past calibrations\u003c\/p\u003e\n\u003cp\u003eand monitors the pH electrode and buffers during subsequent\u003c\/p\u003e\n\u003cp\u003ecalibrations for any signs of wide calibration variances due to a dirty\u003c\/p\u003e\n\u003cp\u003eor broken electrode or contaminated pH buffers. In measurement\u003c\/p\u003e\n\u003cp\u003emode. the electrode's percent condition is continuously displayed.\u003c\/p\u003e\n\u003cp\u003eExchange out the pH probe for an ORP probe to obtain mV readings\u003c\/p\u003e\n\u003cp\u003ein the ±2000 mV range. HI 98184 and HI 98185 adds direct ion\u003c\/p\u003e\n\u003cp\u003econcentration readings for ISE's and the results are displayed in ppm.\u003c\/p\u003e\n\u003cp\u003eThe ion charge or nominal slope can be entered manually.\u003c\/p\u003e\n\u003cp\u003eHI 98185 adds auto recognition of 15 different ISE sensors and can\u003c\/p\u003e\n\u003cp\u003ebe calibrated in up to five points and 6 standard buffers (choice of\u003c\/p\u003e\n\u003cp\u003eunits). This meter allows an extensive choice of measurement units\u003c\/p\u003e\n\u003cp\u003e(ppm. ppt. g\/L. ppb. ug\/L. mg\/mL. M. mol\/L. mmol\/L. % w\/v. user)\u003c\/p\u003e\n\u003cp\u003eand has an expanded measuring range of 1.00 x 10-7 to 9.99 x 10-10.\u003c\/p\u003e\n\u003cp\u003ePress Auto-Hold while measuring and once stabilized. the current\u003c\/p\u003e\n\u003cp\u003ereading will remain displayed for your convenience in documenting.\u003c\/p\u003e\n\u003cp\u003eSwitching to log-on-demand mode allows users to record and save\u003c\/p\u003e\n\u003cp\u003eup to 200 samples (HI 98183) or 300 samples (HI 98184 and\u003c\/p\u003e\n\u003cp\u003eHI 98185). This data can later be transferred to a PC with the USB\u003c\/p\u003e\n\u003cp\u003econnection and HANNA's HI 92000 software. “Out Of Calibration\u003c\/p\u003e\n\u003cp\u003eRange Warning” can be engaged to keep the user informed of the\u003c\/p\u003e\n\u003cp\u003ecurrent calibration and helps to avoid taking measurements that are\u003c\/p\u003e\n\u003cp\u003eout of range.\u003c\/p\u003e\n\u003cp\u003eA backlit. graphic LCD provides easy to read resolution even in lowlit\u003c\/p\u003e\n\u003cp\u003eareas. A combination of dedicated and soft keys allows easy.\u003c\/p\u003e\n\u003cp\u003eintuitive operation in a choice of languages. Comprehensive GLP\u003c\/p\u003e\n\u003cp\u003edata are directly accessible by pressing the GLP key. Access the\u003c\/p\u003e\n\u003cp\u003econtextual Help Menu to obtain on-screen information and\u003c\/p\u003e\n\u003cp\u003eassistance about each feature at the touch of a button. Designed\u003c\/p\u003e\n\u003cp\u003efor field use. these instruments can be operated with one hand and\u003c\/p\u003e\n\u003cp\u003eare supplied in a rugged carrying case. With an extended battery\u003c\/p\u003e\n\u003cp\u003elife of up to 200 hours. users are assured long operation. The\u003c\/p\u003e\n\u003cp\u003einductive charger can either be plugged into a standard 115V\u003c\/p\u003e\n\u003cp\u003esocket with the included adapter or a 12 VDC source. such as a car's\u003c\/p\u003e\n\u003cp\u003e12 V accessory outlet.\u003c\/p\u003e\n\u003cp\u003eThese meters come equipped with the HI 72911B pH\/ temperature\u003c\/p\u003e\n\u003cp\u003eelectrode with rugged. titanium casing.\u003c\/p\u003e\n\u003cp\u003eSPECIFICATIONS HI 98183 HI 98184 HI 98185\u003c\/p\u003e\n\u003cp\u003eRange\u003c\/p\u003e\n\u003cp\u003epH -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH\u003c\/p\u003e\n\u003cp\u003emV ±2000 mV\u003c\/p\u003e\n\u003cp\u003eISE — from 1.00 e-3 to 1.00 e5\u003c\/p\u003e\n\u003cp\u003econcentration\u003c\/p\u003e\n\u003cp\u003efrom 1.00 e-7 to 9.99 e10\u003c\/p\u003e\n\u003cp\u003econcentration\u003c\/p\u003e\n\u003cp\u003eTemperature -20.0 to 120.0 °C (-4.0 to 248.0°F)\u003c\/p\u003e\n\u003cp\u003eResolution\u003c\/p\u003e\n\u003cp\u003epH 0.1; 0.01; 0.001 pH\u003c\/p\u003e\n\u003cp\u003emV 0.1 mV\u003c\/p\u003e\n\u003cp\u003eISE — 3 digits 0.01; 0.1; 1; 10 concentration\u003c\/p\u003e\n\u003cp\u003eTemperature 0.1°C (0.1°F)\u003c\/p\u003e\n\u003cp\u003eAccuracy\u003c\/p\u003e\n\u003cp\u003epH ±0.01; ±0.002 pH\u003c\/p\u003e\n\u003cp\u003emV ±0.2 mV\u003c\/p\u003e\n\u003cp\u003eISE — ±0.5% of reading (monovalent ions).\u003c\/p\u003e\n\u003cp\u003e±1% of reading (divalent ions)\u003c\/p\u003e\n\u003cp\u003eTemperature ±0.4°C (±0.8°F) (excluding probe error)\u003c\/p\u003e\n\u003cp\u003eCalibration\u003c\/p\u003e\n\u003cp\u003epH up to five point calibration. seven standard buffers available\u003c\/p\u003e\n\u003cp\u003e(1.68. 4.01. 6.86. 7.01. 9.18. 10.01. 12.45) + five custom buffers\u003c\/p\u003e\n\u003cp\u003eISE —\u003c\/p\u003e\n\u003cp\u003eup to two point calibration.\u003c\/p\u003e\n\u003cp\u003esix standard solutions\u003c\/p\u003e\n\u003cp\u003e(0.1. 1. 10. 100. 1000.\u003c\/p\u003e\n\u003cp\u003e10000 ppm)\u003c\/p\u003e\n\u003cp\u003eup to five point calibration.\u003c\/p\u003e\n\u003cp\u003esix standard solutions\u003c\/p\u003e\n\u003cp\u003e(0.1. 1. 10. 100. 1000.\u003c\/p\u003e\n\u003cp\u003e10000 ppm)\u003c\/p\u003e\n\u003cp\u003eSlope From 80 to 110%\u003c\/p\u003e\n\u003cp\u003eTemperature Compensation\u003c\/p\u003e\n\u003cp\u003e(pH) manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/p\u003e\n\u003cp\u003eProbe Hi 72911B titanium body. pH electrode with internal temperature sensor.\u003c\/p\u003e\n\u003cp\u003eBnC connector and 1 m (3.3’ cable)\u003c\/p\u003e\n\u003cp\u003eLogging log on demand 200\u003c\/p\u003e\n\u003cp\u003esamples (100 ea. range) log on demand 300 samples (100 each range)\u003c\/p\u003e\n\u003cp\u003ePC Connectivity opto-isolated UsB with optional Hi 92000 software\u003c\/p\u003e\n\u003cp\u003eInput Impedance 1012 ohms\u003c\/p\u003e\n\u003cp\u003eBattery Type \/ Life 1.2V AA rechargeable batteries (4) \/ approximately 200 hours\u003c\/p\u003e\n\u003cp\u003eof continuous use without backlight (50 hours with backlight)\u003c\/p\u003e\n\u003cp\u003eAuto-off user selectable: 5. 10. 30. 60 min or can be disabled\u003c\/p\u003e\n\u003cp\u003eEnvironment 0 to 50°C (32 to 122°F); RH 100%\u003c\/p\u003e\n\u003cp\u003eDimensions 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)\u003c\/p\u003e\n\u003cp\u003eWeight 525 g (18.5 oz.)\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eORDERING INFORMATION\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHI 98183-01 (115V). HI 98183-02 (230V).\u003c\/p\u003e\n\u003cp\u003eHI 98184-01 (115V). HI 98184-02 (230V) and\u003c\/p\u003e\n\u003cp\u003eHI 98185-01 (115V) and HI 98185-02 (230V) are\u003c\/p\u003e\n\u003cp\u003esupplied with HI 72911B pH electrode. HI 70004\u003c\/p\u003e\n\u003cp\u003epH 4.01 buffer solution sachet. HI 70007 pH 7.01\u003c\/p\u003e\n\u003cp\u003ebuffer solution sachet. rechargeable batteries.\u003c\/p\u003e\n\u003cp\u003eHI 710042 inductive battery charger with power\u003c\/p\u003e\n\u003cp\u003eadapter. instructions and hard carrying case.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eELECTRODES AND PROBES\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCombination pH electrodes with BNC connector\u003c\/p\u003e\n\u003cp\u003eand 1 m (3.3’) cable:\u003c\/p\u003e\n\u003cp\u003eHI 1043B Use: strong acids and bases.\u003c\/p\u003e\n\u003cp\u003eglass-body. double junction. refillable\u003c\/p\u003e\n\u003cp\u003eHI 1230B Use: general purpose. PEI body.\u003c\/p\u003e\n\u003cp\u003edouble junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 72911B Use: general purpose. titanium\u003c\/p\u003e\n\u003cp\u003ebody. double junction. gel-filled\u003c\/p\u003e\n\u003cp\u003ewith internal temperature sensor\u003c\/p\u003e\n\u003cp\u003eHI 3230B Use: For oxidizing reactions.\u003c\/p\u003e\n\u003cp\u003eplatinum tipped ORP probe. PEI\u003c\/p\u003e\n\u003cp\u003ebody. single junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 4430B Use: Strong oxidizing solutions\u003c\/p\u003e\n\u003cp\u003egold tipped ORP probe. PEI\u003c\/p\u003e\n\u003cp\u003ebody. single junction. gel-filled\u003c\/p\u003e\n\u003cp\u003eHI 7662 Temperature probe with\u003c\/p\u003e\n\u003cp\u003e1 m (3.3’) screened cable\u003c\/p\u003e\n\u003cp\u003eSOLUTIONS\u003c\/p\u003e\n\u003cp\u003eHI 5004L pH 4.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 5007L pH 7.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 5010L pH 10.01 buffer solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7061L Electrode cleaning solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 70300L Electrode storage solution. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7091L ORP reducing pretreatment solution.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7092L ORP oxidizing pretreatment solution.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7020L ORP test solution @200-275 mV.\u003c\/p\u003e\n\u003cp\u003e500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7021L ORP test solution @240 mV. 500 mL\u003c\/p\u003e\n\u003cp\u003eHI 7022L ORP test solution @470 mV. 500 mL\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eACCESSORIES\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eHI 920013 USB cable for PC connection\u003c\/p\u003e\n\u003cp\u003eHI 92000 Windows® compatible software\u003c\/p\u003e"}










