Email info@acornsci.com for orders and inquiries.

{"id":1582065221,"title":"HANNA HI 749 Checker HC ® - Chromium VI. LR","handle":"hi749","description":"\u003cp style=\"text-align: justify;\"\u003eThe HI 749 Checker®HC is a simple. accurate. and cost effective way to measure low ranges of chromium VI in fresh water.  Designed as a more accurate alternative to chemical test kits. the HI 749 provides quick. accurate results in four easy steps.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 749 uses an adaptation of the ASTM Manual of Water and Environmental Technology. D1687-92. Diphenylcarbohydrazide method. The reaction between chromium VI and the reagent causes a purple tint in the sample.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   The HI 749 Checker®HC is supplied with 2 cuvettes and caps. reagent starter kit (6 packets of chromium VI LR reagent). 1 x 1.5V AAA battery. and an instruction manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 300 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C\/77°F)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±3 ppb ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eColorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePhotodiode @525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of ASTM Manual of Water \u0026amp; Environmental Technology. D1687-92. Diphenylcarbohydrazide method. The reaction between chromium VI and the reagent causes a purple tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBattery - 1 x 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Auto Off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 min. of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) Weight 64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","published_at":"2026-06-25T16:31:17+12:00","created_at":"2015-09-01T15:02:14+12:00","vendor":"Hanna Instruments","type":"Electrochemical","tags":["Manufacturer_Hanna Instruments","Type_Colorimeter"],"price":8900,"price_min":8900,"price_max":8900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":4857030597,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"HI749","requires_shipping":false,"taxable":true,"featured_image":null,"available":true,"name":"HANNA HI 749 Checker HC ® - Chromium VI. LR","public_title":null,"options":["Default Title"],"price":8900,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-chrom-vi-niedrig-2422_1-151cb140e2335c_2015.jpeg?v=1443494428"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-chrom-vi-niedrig-2422_1-151cb140e2335c_2015.jpeg?v=1443494428","options":["Title"],"media":[{"alt":"HI 749 Checker HC ® - Chromium VI. LR - Acorn Scientific","id":21265711203,"position":1,"preview_image":{"aspect_ratio":1.0,"height":800,"width":800,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-chrom-vi-niedrig-2422_1-151cb140e2335c_2015.jpeg?v=1443494428"},"aspect_ratio":1.0,"height":800,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/mini-photometer-fur-chrom-vi-niedrig-2422_1-151cb140e2335c_2015.jpeg?v=1443494428","width":800}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp style=\"text-align: justify;\"\u003eThe HI 749 Checker®HC is a simple. accurate. and cost effective way to measure low ranges of chromium VI in fresh water.  Designed as a more accurate alternative to chemical test kits. the HI 749 provides quick. accurate results in four easy steps.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003eThe HI 749 uses an adaptation of the ASTM Manual of Water and Environmental Technology. D1687-92. Diphenylcarbohydrazide method. The reaction between chromium VI and the reagent causes a purple tint in the sample.\u003c\/p\u003e\n\u003cp style=\"text-align: justify;\"\u003e\u003cstrong\u003eOrder Information:\u003c\/strong\u003e   The HI 749 Checker®HC is supplied with 2 cuvettes and caps. reagent starter kit (6 packets of chromium VI LR reagent). 1 x 1.5V AAA battery. and an instruction manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification :\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable class=\"spec_table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 300 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25°C\/77°F)\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e±3 ppb ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eColorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003ePhotodiode @525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Detector\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eSilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAdaptation of ASTM Manual of Water \u0026amp; Environmental Technology. D1687-92. Diphenylcarbohydrazide method. The reaction between chromium VI and the reagent causes a purple tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eBattery - 1 x 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Auto Off\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003eAfter 10 min. of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) Weight 64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e"}

HANNA HI 749 Checker HC ® - Chromium VI. LR

Product Description

The HI 749 Checker®HC is a simple. accurate. and cost effective way to measure low ranges of chromium VI in fresh water.  Designed as a more accurate alternative to chemical test kits. the HI 749 provides quick. accurate results in four easy steps.

The HI 749 uses an adaptation of the ASTM Manual of Water and Environmental Technology. D1687-92. Diphenylcarbohydrazide method. The reaction between chromium VI and the reagent causes a purple tint in the sample.

Order Information:   The HI 749 Checker®HC is supplied with 2 cuvettes and caps. reagent starter kit (6 packets of chromium VI LR reagent). 1 x 1.5V AAA battery. and an instruction manual.

Specification :

Range   0 to 300 ppb
Resolution   1 ppb
Accuracy (@25°C/77°F)   ±3 ppb ±5% of reading
Measurement Method   Colorimetric
Light Source   Photodiode @525 nm
Light Detector   Silicon photocell
Method   Adaptation of ASTM Manual of Water & Environmental Technology. D1687-92. Diphenylcarbohydrazide method. The reaction between chromium VI and the reagent causes a purple tint in the sample.
Power Supply   Battery - 1 x 1.5V AAA
Power Auto Off   After 10 min. of inactivity
Environment   0 to 50°C (32 to 122°F); RH max 95% non-condensing
Dimensions   81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) Weight 64 g (2.25 oz.)

This product is available upon request. Contact us for more information.