Email info@acornsci.com for orders and inquiries.

{"id":8863677186344,"title":"OPSIS HydROC Hydrolysis","handle":"opsis-hydroc-hydrolysis","description":"\u003cp\u003e\u003cspan\u003eREDUCE COST AND ERRORS FOR TOTAL FAT DETERMINATIONS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHYDROC HYDROLYSIS UNIT\u003c\/h2\u003e\n\u003cp\u003eOPSIS LiquidLINE brings an innovative solution for acid hydrolysis, making total fat determinations more efficient and safe. The hazardous hydrolysis process can now safely be performed with up to six samples simultaneously. The unique HydROC filter brings additional cost and time savings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSave Costs with Clever Filter Technology\u003c\/strong\u003e\u003cbr\u003eThe HydROC filter can be used several times which makes it more cost efficient than any other solution on the market.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClever solution saves cost on other consumables.\u003c\/li\u003e\n\u003cli\u003eSystem compatible with several other extraction systems on the market.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReduce Errors in Total Fat Analysis\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe HydROC filter can be used in both hydrolysis and extraction steps, avoiding sample transfer errors and saving time.\u003c\/li\u003e\n\u003cli\u003eThe HydROC and SoxROC batch handling system saves time when moving samples between hydrolysis and extraction.\u003c\/li\u003e\n\u003cli\u003eComplete separation of samples removes the risk for contamination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafe Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe acid hydrolysis is performed in a closed system, reducing risks for the operator.\u003c\/li\u003e\n\u003cli\u003eSample rinsing without any contact with acid reduces safety hazards.\u003c\/li\u003e\n\u003cli\u003eComplies with standardized methods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFIBER EXPANSION\u003c\/h2\u003e\n\u003cp\u003eThe OPSIS LiquidLINE HydROC unit can be further expanded with a Fiber analysis kit.\u003c\/p\u003e\n\u003cp\u003eThe expansion kit consists of specific boiling cups and OPSIS LiquidLINE unique fiber bags for analysis according to the Weende method (Crude Fiber).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eTHE HYDROC PORTFOLIO\u003c\/h2\u003e\n\u003cp\u003eSX-110, HydROC 6 position Hydrolysis Unit\u003cbr\u003eFB-120-C, FiberROC Manual 6 position Fiber and Hydrolysis unit\u003cbr\u003eFB-010-C, Fiber Expansion Kit to HydROC\u003cbr\u003eAccessories and Consumables\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/OPSIS_HydROC_Hydrolysis_Brochure.pdf?v=1706149493\" target=\"_blank\" title=\"OPSIS HydROC Hydrolysis\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-5_medium.png?771451745318071210\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e","published_at":"2024-01-24T15:26:01+13:00","created_at":"2024-01-24T15:25:16+13:00","vendor":"Opsis","type":"","tags":["Category_Wet Chemistry","Manufacturer_Opsis","Type_Fat Determination","Type_Fiber Determination","Type_Hydrolysis"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":47513098322216,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":null,"requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"OPSIS HydROC Hydrolysis","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/files\/HydROCHydrolysis1.jpg?v=1706063750","\/\/acornsci.co.nz\/cdn\/shop\/files\/HydROCHydrolysis2.jpg?v=1706063752"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/files\/HydROCHydrolysis1.jpg?v=1706063750","options":["Title"],"media":[{"alt":null,"id":37548592070952,"position":1,"preview_image":{"aspect_ratio":1.0,"height":375,"width":375,"src":"\/\/acornsci.co.nz\/cdn\/shop\/files\/HydROCHydrolysis1.jpg?v=1706063750"},"aspect_ratio":1.0,"height":375,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/files\/HydROCHydrolysis1.jpg?v=1706063750","width":375},{"alt":null,"id":37548592529704,"position":2,"preview_image":{"aspect_ratio":1.0,"height":375,"width":375,"src":"\/\/acornsci.co.nz\/cdn\/shop\/files\/HydROCHydrolysis2.jpg?v=1706063752"},"aspect_ratio":1.0,"height":375,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/files\/HydROCHydrolysis2.jpg?v=1706063752","width":375}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cspan\u003eREDUCE COST AND ERRORS FOR TOTAL FAT DETERMINATIONS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHYDROC HYDROLYSIS UNIT\u003c\/h2\u003e\n\u003cp\u003eOPSIS LiquidLINE brings an innovative solution for acid hydrolysis, making total fat determinations more efficient and safe. The hazardous hydrolysis process can now safely be performed with up to six samples simultaneously. The unique HydROC filter brings additional cost and time savings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSave Costs with Clever Filter Technology\u003c\/strong\u003e\u003cbr\u003eThe HydROC filter can be used several times which makes it more cost efficient than any other solution on the market.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClever solution saves cost on other consumables.\u003c\/li\u003e\n\u003cli\u003eSystem compatible with several other extraction systems on the market.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReduce Errors in Total Fat Analysis\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe HydROC filter can be used in both hydrolysis and extraction steps, avoiding sample transfer errors and saving time.\u003c\/li\u003e\n\u003cli\u003eThe HydROC and SoxROC batch handling system saves time when moving samples between hydrolysis and extraction.\u003c\/li\u003e\n\u003cli\u003eComplete separation of samples removes the risk for contamination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafe Design\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe acid hydrolysis is performed in a closed system, reducing risks for the operator.\u003c\/li\u003e\n\u003cli\u003eSample rinsing without any contact with acid reduces safety hazards.\u003c\/li\u003e\n\u003cli\u003eComplies with standardized methods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eFIBER EXPANSION\u003c\/h2\u003e\n\u003cp\u003eThe OPSIS LiquidLINE HydROC unit can be further expanded with a Fiber analysis kit.\u003c\/p\u003e\n\u003cp\u003eThe expansion kit consists of specific boiling cups and OPSIS LiquidLINE unique fiber bags for analysis according to the Weende method (Crude Fiber).\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eTHE HYDROC PORTFOLIO\u003c\/h2\u003e\n\u003cp\u003eSX-110, HydROC 6 position Hydrolysis Unit\u003cbr\u003eFB-120-C, FiberROC Manual 6 position Fiber and Hydrolysis unit\u003cbr\u003eFB-010-C, Fiber Expansion Kit to HydROC\u003cbr\u003eAccessories and Consumables\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/OPSIS_HydROC_Hydrolysis_Brochure.pdf?v=1706149493\" target=\"_blank\" title=\"OPSIS HydROC Hydrolysis\" rel=\"noopener noreferrer\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-5_medium.png?771451745318071210\" alt=\"\"\u003e\u003c\/a\u003e\u003c\/p\u003e"}

OPSIS HydROC Hydrolysis

Product Description

REDUCE COST AND ERRORS FOR TOTAL FAT DETERMINATIONS

 

HYDROC HYDROLYSIS UNIT

OPSIS LiquidLINE brings an innovative solution for acid hydrolysis, making total fat determinations more efficient and safe. The hazardous hydrolysis process can now safely be performed with up to six samples simultaneously. The unique HydROC filter brings additional cost and time savings.

Save Costs with Clever Filter Technology
The HydROC filter can be used several times which makes it more cost efficient than any other solution on the market.

  • Clever solution saves cost on other consumables.
  • System compatible with several other extraction systems on the market.

Reduce Errors in Total Fat Analysis

  • The HydROC filter can be used in both hydrolysis and extraction steps, avoiding sample transfer errors and saving time.
  • The HydROC and SoxROC batch handling system saves time when moving samples between hydrolysis and extraction.
  • Complete separation of samples removes the risk for contamination.

Safe Design

  • The acid hydrolysis is performed in a closed system, reducing risks for the operator.
  • Sample rinsing without any contact with acid reduces safety hazards.
  • Complies with standardized methods.

 

FIBER EXPANSION

The OPSIS LiquidLINE HydROC unit can be further expanded with a Fiber analysis kit.

The expansion kit consists of specific boiling cups and OPSIS LiquidLINE unique fiber bags for analysis according to the Weende method (Crude Fiber).

 

THE HYDROC PORTFOLIO

SX-110, HydROC 6 position Hydrolysis Unit
FB-120-C, FiberROC Manual 6 position Fiber and Hydrolysis unit
FB-010-C, Fiber Expansion Kit to HydROC
Accessories and Consumables

 

This product is available upon request. Contact us for more information.