Email info@acornsci.com for orders and inquiries.

{"id":4506162430051,"title":"K Lab: OPTIZEN™ Alpha Spectrophotometer","handle":"optizen-alpha","description":"\u003cdiv align=\"left\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv class=\"inner\"\u003e\n\u003cp class=\"desc col-xs-12 col-sm-6\"\u003eOPTIZEN Alpha can measure quantitative characteristics such as density or purity by measuring transmittance or optical density according to wavelength of sample in ultraviolet and visible ranges.\u003cbr\u003e\u003cbr\u003eOPTIZEN SERIES can be utilized for not only  general analysis but also for specialized research . Guarantee accurate measurement and excellent reproducibility, providing reliable results in various fields such as environmental , biotechnology, chemistry, etc.\u003c\/p\u003e\n\u003cp class=\"desc col-xs-12 col-sm-6\"\u003e\u003cstrong class=\"title\"\u003eProduct Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhotometrics System\u003c\/th\u003e\n\u003ctd\u003eDouble-beam type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpectral Bandwidth\u003c\/th\u003e\n\u003ctd\u003e1 nm (190 to 1100 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWavelength Range\u003c\/th\u003e\n\u003ctd\u003e190 to 1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWavelength Setting\u003c\/th\u003e\n\u003ctd\u003e0.05 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWavelength Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.3 nm (For entire range) \u003cbr\u003e±0.1 nm (656.1 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWavelength Repeatability\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;± 0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSlew Rate\u003c\/th\u003e\n\u003ctd\u003eAbout 8,800 nm\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScan Speed\u003c\/th\u003e\n\u003ctd\u003emax 6,000 nm\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhotometric Range\u003c\/th\u003e\n\u003ctd\u003eAbsorbance : -4 to 4 Abs\u003cbr\u003e Transmittance : 0 % to 400 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhotometric Accuracy\u003c\/th\u003e\n\u003ctd\u003eLess than ± 0.005 Abs at 1.0 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight Source\u003c\/th\u003e\n\u003ctd\u003eTungsten Halogen Lamp \u0026amp; Deuterium Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStray light\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.02 % Nal at 220 nm, NaNO₂ at 340 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhotometric repeatability\u003c\/th\u003e\n\u003ctd\u003e± 0.0002 at 0.5 Abs \u003cbr\u003e± 0.0006 at 1.0 Abs \u003cbr\u003e± 0.001 at 2.0 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBaseline stability\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.0003 Abs\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBaseline flatness\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;± 0.0005 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLamp interchange Wavelength\u003c\/th\u003e\n\u003ctd\u003e340~410 nm (Default 370 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Requirement\u003c\/th\u003e\n\u003ctd\u003e100~240 V; 50~60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating system(OS)\u003c\/th\u003e\n\u003ctd\u003eWindows 10 (Embedded PC);\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight(kg)\u003c\/th\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions(WxDxH)\u003c\/th\u003e\n\u003ctd\u003e520(W)x500(D)x200(H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard cell Holder\u003c\/th\u003e\n\u003ctd\u003eAutometic Rotary type 8-position Multi-Cell Holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e","published_at":"2020-03-13T15:30:51+13:00","created_at":"2020-03-13T15:30:51+13:00","vendor":"K Lab","type":"Spectrophotometers","tags":["Category_Spectrophotometers","Manufacturer_K Lab","Type_Devices"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":0,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":32225918386275,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"K Lab: OPTIZEN™ Alpha Spectrophotometer","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":0,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/optizen_alpha1.png?v=1584066682"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/optizen_alpha1.png?v=1584066682","options":["Title"],"media":[{"alt":null,"id":6667359748195,"position":1,"preview_image":{"aspect_ratio":0.982,"height":659,"width":647,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/optizen_alpha1.png?v=1584066682"},"aspect_ratio":0.982,"height":659,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/optizen_alpha1.png?v=1584066682","width":647}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cdiv align=\"left\"\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv class=\"inner\"\u003e\n\u003cp class=\"desc col-xs-12 col-sm-6\"\u003eOPTIZEN Alpha can measure quantitative characteristics such as density or purity by measuring transmittance or optical density according to wavelength of sample in ultraviolet and visible ranges.\u003cbr\u003e\u003cbr\u003eOPTIZEN SERIES can be utilized for not only  general analysis but also for specialized research . Guarantee accurate measurement and excellent reproducibility, providing reliable results in various fields such as environmental , biotechnology, chemistry, etc.\u003c\/p\u003e\n\u003cp class=\"desc col-xs-12 col-sm-6\"\u003e\u003cstrong class=\"title\"\u003eProduct Specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"specification\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhotometrics System\u003c\/th\u003e\n\u003ctd\u003eDouble-beam type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSpectral Bandwidth\u003c\/th\u003e\n\u003ctd\u003e1 nm (190 to 1100 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWavelength Range\u003c\/th\u003e\n\u003ctd\u003e190 to 1100 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWavelength Setting\u003c\/th\u003e\n\u003ctd\u003e0.05 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWavelength Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.3 nm (For entire range) \u003cbr\u003e±0.1 nm (656.1 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWavelength Repeatability\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;± 0.1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSlew Rate\u003c\/th\u003e\n\u003ctd\u003eAbout 8,800 nm\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eScan Speed\u003c\/th\u003e\n\u003ctd\u003emax 6,000 nm\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhotometric Range\u003c\/th\u003e\n\u003ctd\u003eAbsorbance : -4 to 4 Abs\u003cbr\u003e Transmittance : 0 % to 400 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhotometric Accuracy\u003c\/th\u003e\n\u003ctd\u003eLess than ± 0.005 Abs at 1.0 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLight Source\u003c\/th\u003e\n\u003ctd\u003eTungsten Halogen Lamp \u0026amp; Deuterium Lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStray light\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.02 % Nal at 220 nm, NaNO₂ at 340 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePhotometric repeatability\u003c\/th\u003e\n\u003ctd\u003e± 0.0002 at 0.5 Abs \u003cbr\u003e± 0.0006 at 1.0 Abs \u003cbr\u003e± 0.001 at 2.0 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBaseline stability\u003c\/th\u003e\n\u003ctd\u003e\u0026lt; 0.0003 Abs\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBaseline flatness\u003c\/th\u003e\n\u003ctd\u003e\u0026lt;± 0.0005 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eLamp interchange Wavelength\u003c\/th\u003e\n\u003ctd\u003e340~410 nm (Default 370 nm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Requirement\u003c\/th\u003e\n\u003ctd\u003e100~240 V; 50~60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating system(OS)\u003c\/th\u003e\n\u003ctd\u003eWindows 10 (Embedded PC);\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight(kg)\u003c\/th\u003e\n\u003ctd\u003e14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDimensions(WxDxH)\u003c\/th\u003e\n\u003ctd\u003e520(W)x500(D)x200(H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eStandard cell Holder\u003c\/th\u003e\n\u003ctd\u003eAutometic Rotary type 8-position Multi-Cell Holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e"}

K Lab: OPTIZEN™ Alpha Spectrophotometer

Product Description
  • OPTIZEN Alpha can measure quantitative characteristics such as density or purity by measuring transmittance or optical density according to wavelength of sample in ultraviolet and visible ranges.

    OPTIZEN SERIES can be utilized for not only  general analysis but also for specialized research . Guarantee accurate measurement and excellent reproducibility, providing reliable results in various fields such as environmental , biotechnology, chemistry, etc.

    Product Specifications

    Photometrics System Double-beam type
    Spectral Bandwidth 1 nm (190 to 1100 nm)
    Wavelength Range 190 to 1100 nm
    Wavelength Setting 0.05 nm
    Wavelength Accuracy ±0.3 nm (For entire range)
    ±0.1 nm (656.1 nm)
    Wavelength Repeatability <± 0.1 nm
    Slew Rate About 8,800 nm/min
    Scan Speed max 6,000 nm/min
    Photometric Range Absorbance : -4 to 4 Abs
    Transmittance : 0 % to 400 %
    Photometric Accuracy Less than ± 0.005 Abs at 1.0 Abs
    Light Source Tungsten Halogen Lamp & Deuterium Lamp
    Stray light < 0.02 % Nal at 220 nm, NaNO₂ at 340 nm
    Photometric repeatability ± 0.0002 at 0.5 Abs
    ± 0.0006 at 1.0 Abs
    ± 0.001 at 2.0 Abs
    Baseline stability < 0.0003 Abs/h
    Baseline flatness <± 0.0005 Abs
    Lamp interchange Wavelength 340~410 nm (Default 370 nm)
    Power Requirement 100~240 V; 50~60 Hz
    Operating system(OS) Windows 10 (Embedded PC);
    Weight(kg) 14 kg
    Dimensions(WxDxH) 520(W)x500(D)x200(H)
    Standard cell Holder Autometic Rotary type 8-position Multi-Cell Holder

This product is available upon request. Contact us for more information.

Liquid error (layout/theme line 139): Could not find asset snippets/beae_footer.liquid