{"id":6658447769699,"title":"CARBOLITE GERO CWF1223-230SN Chamber Furnace 23L","handle":"carbolite-gero-cwf1223-230sn-chamber-furnace-23l","description":"\u003cp id=\"intro\" style=\"background-color: transparent; border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; clear: left; color: #333333; font-family: Verdana,Arial,sans-serif; font-size: 15px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px 0px 15px 0px; border: 0px none #333333;\"\u003eThe \u003cb style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; font-size: 15px; font-weight: bold; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF \u003c\/b\u003erange of general purpose laboratory chamber furnaces is bench mounted. Models are available in five sizes with a maximum operating temperature up to 1300 °C.\u003cbr style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; clear: none; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e\u003cbr style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; clear: none; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e The airflow in the \u003cb style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; font-size: 15px; font-weight: bold; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-B \u003c\/b\u003efurnaces is enhanced by the addition of air inlet holes in the door and a tall chimney which rapidly removes the fumes from the furnace. \u003cbr style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; clear: none; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e\u003cbr style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; clear: none; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e The \u003cb style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; font-size: 15px; font-weight: bold; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-BAL\u003c\/b\u003e furnace with integral balance can be used for thermogravimetric analysis (TGA) and loss on ignition (LOI) applications, where weight change of the sample must be monitored during the heating process. This is required, for example, in the determination of inorganic matter content in materials such as cement, lime, calcinated bauxite and refractories. For applications involving organic matter content, please refer to the AAF-BAL.\u003c\/p\u003e\n\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #333333; font-family: Verdana,Arial,sans-serif; font-size: 15px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003e \u003c\/span\u003e\n\u003ch2 id=\"advantages\" style=\"background-color: transparent; border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; color: #e30613; font-family: Verdana,Arial,sans-serif; font-size: 18.75px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 30px 0px 15px 0px; border: 0px none #e30613;\"\u003eStandard features\u003c\/h2\u003e\n\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #333333; font-family: Verdana,Arial,sans-serif; font-size: 15px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003e \u003c\/span\u003e\n\u003cul style=\"background-color: transparent; border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; color: #333333; font-family: Verdana,Arial,sans-serif; font-size: 15px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; list-style-image: url('https:\/\/www.carbolite-gero.com\/assets\/global\/all\/web-2017\/img\/list-bullet-rectangle-gray.png'); list-style-position: outside; list-style-type: disc; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px 0px 0px 15px; margin: 0px 0px 15px 0px; border: 0px none #333333;\"\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e1100°C, 1200°C or 1300°C maximum operating temperature\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e5, 13, 23, 36 or 65 litre chamber volumes\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCarbolite Gero 301 controller, with single ramp to set-point \u0026amp; process timer\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eSoft closing door on 5, 13, 21 \u0026amp; 23 litre models\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eParallel action door keeps heated surface away from the user\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eDelayed start \/ process timer function as standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul style=\"background-color: transparent; border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; color: #333333; font-family: Verdana,Arial,sans-serif; font-size: 15px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; list-style-image: url('https:\/\/www.carbolite-gero.com\/assets\/global\/all\/web-2017\/img\/list-bullet-rectangle-gray.png'); list-style-position: outside; list-style-type: disc; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px 0px 0px 15px; margin: 0px 0px 15px 0px; border: 0px none #333333;\"\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eHard wearing alumina element carrier, furnace entrance and hearth\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eEnergy efficient low thermal mass insulation\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eFree radiating wire wound elements for optimum uniformity\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eEasy access to elements \u0026amp; controls simplifies maintenance \u0026amp; servicing\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-B: Enhanced airflow from tall chimney \u0026amp; door vents for full combustion\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-BAL: With integrated balance that runs independently of the furnace control system\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-BAL: Software supplied with the balance may be used to monitor the balance reading via a computer\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-BAL: Maximum capacity of balance is 3 kg with a resolution of 0.01 g (other capacities available)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca title=\"CWF Brochure\" href=\"https:\/\/www.carbolite-gero.com\/dltmp\/www\/53e4b581-ac1c-4a18-a982-636500000000-df492febc5ee\/brochure_catalogue_general_en.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-5_large.png?v=1470169749\"\u003e\u003c\/a\u003e\u003c\/p\u003e","published_at":"2021-10-29T14:19:55+13:00","created_at":"2021-10-29T14:19:55+13:00","vendor":"Carbolite Gero","type":"Ovens \/ Furnaces","tags":["brand_Carbolite Gero","Capacity_23L","Category_Ovens \/ Furnaces","Industry_Industrial Manufacturing","Manufacturer_Carbolite Gero","Temperature_1200°C","Type_High Temp"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":39628226035811,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"CWF1223-230SN","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"CARBOLITE GERO CWF1223-230SN Chamber Furnace 23L","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":0,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/pic-cwf11-13-cc-t1_bc72287a-f64e-4f10-96e2-f69b8973dd90.png?v=1635470408"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/pic-cwf11-13-cc-t1_bc72287a-f64e-4f10-96e2-f69b8973dd90.png?v=1635470408","options":["Title"],"media":[{"alt":null,"id":20949929394275,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/pic-cwf11-13-cc-t1_bc72287a-f64e-4f10-96e2-f69b8973dd90.png?v=1635470408"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/pic-cwf11-13-cc-t1_bc72287a-f64e-4f10-96e2-f69b8973dd90.png?v=1635470408","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp id=\"intro\" style=\"background-color: transparent; border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; clear: left; color: #333333; font-family: Verdana,Arial,sans-serif; font-size: 15px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 0px 0px 15px 0px; border: 0px none #333333;\"\u003eThe \u003cb style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; font-size: 15px; font-weight: bold; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF \u003c\/b\u003erange of general purpose laboratory chamber furnaces is bench mounted. Models are available in five sizes with a maximum operating temperature up to 1300 °C.\u003cbr style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; clear: none; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e\u003cbr style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; clear: none; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e The airflow in the \u003cb style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; font-size: 15px; font-weight: bold; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-B \u003c\/b\u003efurnaces is enhanced by the addition of air inlet holes in the door and a tall chimney which rapidly removes the fumes from the furnace. \u003cbr style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; clear: none; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e\u003cbr style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; clear: none; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e The \u003cb style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; font-size: 15px; font-weight: bold; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-BAL\u003c\/b\u003e furnace with integral balance can be used for thermogravimetric analysis (TGA) and loss on ignition (LOI) applications, where weight change of the sample must be monitored during the heating process. This is required, for example, in the determination of inorganic matter content in materials such as cement, lime, calcinated bauxite and refractories. For applications involving organic matter content, please refer to the AAF-BAL.\u003c\/p\u003e\n\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #333333; font-family: Verdana,Arial,sans-serif; font-size: 15px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003e \u003c\/span\u003e\n\u003ch2 id=\"advantages\" style=\"background-color: transparent; border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; color: #e30613; font-family: Verdana,Arial,sans-serif; font-size: 18.75px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px; margin: 30px 0px 15px 0px; border: 0px none #e30613;\"\u003eStandard features\u003c\/h2\u003e\n\u003cspan style=\"display: inline !important; float: none; background-color: transparent; color: #333333; font-family: Verdana,Arial,sans-serif; font-size: 15px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px;\"\u003e \u003c\/span\u003e\n\u003cul style=\"background-color: transparent; border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; color: #333333; font-family: Verdana,Arial,sans-serif; font-size: 15px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; list-style-image: url('https:\/\/www.carbolite-gero.com\/assets\/global\/all\/web-2017\/img\/list-bullet-rectangle-gray.png'); list-style-position: outside; list-style-type: disc; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px 0px 0px 15px; margin: 0px 0px 15px 0px; border: 0px none #333333;\"\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e1100°C, 1200°C or 1300°C maximum operating temperature\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003e5, 13, 23, 36 or 65 litre chamber volumes\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCarbolite Gero 301 controller, with single ramp to set-point \u0026amp; process timer\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eSoft closing door on 5, 13, 21 \u0026amp; 23 litre models\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eParallel action door keeps heated surface away from the user\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eDelayed start \/ process timer function as standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul style=\"background-color: transparent; border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; color: #333333; font-family: Verdana,Arial,sans-serif; font-size: 15px; font-style: normal; font-variant: normal; font-weight: 400; letter-spacing: normal; list-style-image: url('https:\/\/www.carbolite-gero.com\/assets\/global\/all\/web-2017\/img\/list-bullet-rectangle-gray.png'); list-style-position: outside; list-style-type: disc; orphans: 2; text-align: left; text-decoration: none; text-indent: 0px; text-transform: none; -webkit-text-stroke-width: 0px; white-space: normal; word-spacing: 0px; padding: 0px 0px 0px 15px; margin: 0px 0px 15px 0px; border: 0px none #333333;\"\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eHard wearing alumina element carrier, furnace entrance and hearth\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eEnergy efficient low thermal mass insulation\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eFree radiating wire wound elements for optimum uniformity\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eEasy access to elements \u0026amp; controls simplifies maintenance \u0026amp; servicing\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-B: Enhanced airflow from tall chimney \u0026amp; door vents for full combustion\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-BAL: With integrated balance that runs independently of the furnace control system\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-BAL: Software supplied with the balance may be used to monitor the balance reading via a computer\u003c\/li\u003e\n\u003cli style=\"border-image-outset: 0; border-image-repeat: stretch; border-image-slice: 100%; border-image-source: none; border-image-width: 1; display: list-item; font-size: 15px; padding: 0px; margin: 0px; border: 0px none #333333;\"\u003eCWF-BAL: Maximum capacity of balance is 3 kg with a resolution of 0.01 g (other capacities available)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca title=\"CWF Brochure\" href=\"https:\/\/www.carbolite-gero.com\/dltmp\/www\/53e4b581-ac1c-4a18-a982-636500000000-df492febc5ee\/brochure_catalogue_general_en.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-5_large.png?v=1470169749\"\u003e\u003c\/a\u003e\u003c\/p\u003e"}

CARBOLITE GERO CWF1223-230SN Chamber Furnace 23L

Product Description

The CWF range of general purpose laboratory chamber furnaces is bench mounted. Models are available in five sizes with a maximum operating temperature up to 1300 °C.

The airflow in the CWF-B furnaces is enhanced by the addition of air inlet holes in the door and a tall chimney which rapidly removes the fumes from the furnace.

The CWF-BAL furnace with integral balance can be used for thermogravimetric analysis (TGA) and loss on ignition (LOI) applications, where weight change of the sample must be monitored during the heating process. This is required, for example, in the determination of inorganic matter content in materials such as cement, lime, calcinated bauxite and refractories. For applications involving organic matter content, please refer to the AAF-BAL.

Standard features

  • 1100°C, 1200°C or 1300°C maximum operating temperature
  • 5, 13, 23, 36 or 65 litre chamber volumes
  • Carbolite Gero 301 controller, with single ramp to set-point & process timer
  • Soft closing door on 5, 13, 21 & 23 litre models
  • Parallel action door keeps heated surface away from the user
  • Delayed start / process timer function as standard
  • Hard wearing alumina element carrier, furnace entrance and hearth
  • Energy efficient low thermal mass insulation
  • Free radiating wire wound elements for optimum uniformity
  • Easy access to elements & controls simplifies maintenance & servicing
  • CWF-B: Enhanced airflow from tall chimney & door vents for full combustion
  • CWF-BAL: With integrated balance that runs independently of the furnace control system
  • CWF-BAL: Software supplied with the balance may be used to monitor the balance reading via a computer
  • CWF-BAL: Maximum capacity of balance is 3 kg with a resolution of 0.01 g (other capacities available)