Email info@acornsci.com for orders and inquiries.

{"id":5617847365,"title":"CARBOLITE GERO AX030-230SN Fan Assisted Bench Top Oven 30L","handle":"laboratory-bench-top-oven-ax","description":"\u003cp\u003e\u003cb\u003eThe Apex AX Series Ovens are a range of 250°C laboratory ovens\u003c\/b\u003e, comprising three bench-top sized models that are equipped with the R38 digital PID temperature controller.\u003c\/p\u003e\n\u003ch2\u003eStandard features\u003c\/h2\u003e\n\u003cul id=\"advantages\"\u003e\n\u003cli\u003e250°C maximum operating temperature\u003c\/li\u003e\n\u003cli\u003e30, 60 or 120 litres chamber volumes\u003c\/li\u003e\n\u003cli\u003eEquipped with the \u003ca title=\"Opens internal link in current window\" class=\"internal-link\" href=\"http:\/\/www.carbolite-gero.com\/products\/ovens\/laboratory-ovens\/ax-laboratory-bench-top-oven\/products\/control-options\/r38-basic-controller\/\"\u003eR38 digital PID temperature controller\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eFan convection for rapid heating \u0026amp; excellent uniformity\u003c\/li\u003e\n\u003cli\u003eChemically resistant stainless steel liner\u003c\/li\u003e\n\u003cli\u003eTwo adjustable nickel-chrome plated wire shelves\u003c\/li\u003e\n\u003cli\u003eLever latch door \u0026amp; airtight silicone seal\u003c\/li\u003e\n\u003cli\u003eCompliant with safety standard BS EN 61010-2-010:2003\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptions\u003c\/h2\u003e\n\u003cul class=\"list bidspecs\" id=\"options\"\u003e\n\u003cli\u003eOver-temperature protection (recommended to protect valuable contents \u0026amp; for unattended operation)\u003c\/li\u003e\n\u003cli\u003eDigital countdown timer to switch oven off\u003c\/li\u003e\n\u003cli\u003eAdditional sets of shelves \u0026amp; runners\u003c\/li\u003e\n\u003cli\u003eLockable door\u003c\/li\u003e\n\u003cli\u003eLow voltage options for use below 220 V\u003c\/li\u003e\n\u003cli\u003eRoutine spares kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"text-image\"\u003e\n\u003cdiv class=\"grid-100 tablet-grid-100\"\u003e\n\u003ch2 class=\"text-center s-small w-medium t-upper\"\u003eLABORATORY OVEN - AX \u003cspan class=\"s-medium w-bold t-upper\"\u003eTECHNICAL DATA\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_details product-content-features-models\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eAX30\u003c\/th\u003e\n\u003cth\u003eAX60\u003c\/th\u003e\n\u003cth\u003eAX120\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax temp\u003c\/td\u003e\n\u003ctd\u003e250°C\u003c\/td\u003e\n\u003ctd\u003e250°C\u003c\/td\u003e\n\u003ctd\u003e250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin temp\u003c\/td\u003e\n\u003ctd\u003eAmbient +30°C\u003c\/td\u003e\n\u003ctd\u003eAmbient +30°C\u003c\/td\u003e\n\u003ctd\u003eAmbient +30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume (litres)\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp uniformity (°C)\u003c\/td\u003e\n\u003ctd\u003e±5.0 @ 250°C\u003c\/td\u003e\n\u003ctd\u003e±5.0 @ 250°C\u003c\/td\u003e\n\u003ctd\u003e±5.0 @ 250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat-up time (mins)\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecovery time (mins)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions:\u003cbr\u003eInternal H x W x D (mm)\u003c\/td\u003e\n\u003ctd\u003e295 x 300 x 320\u003c\/td\u003e\n\u003ctd\u003e395 x 400 x 420\u003c\/td\u003e\n\u003ctd\u003e495 x 500 x 520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions:\u003cbr\u003eExternal H x W x D (mm)\u003c\/td\u003e\n\u003ctd\u003e440 x 590 x 465\u003c\/td\u003e\n\u003ctd\u003e540 x 690 x 565\u003c\/td\u003e\n\u003ctd\u003e640 x 790 x 665\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShelves fitted \/ accepted\u003c\/td\u003e\n\u003ctd\u003e2 \/ 4\u003c\/td\u003e\n\u003ctd\u003e2 \/ 6\u003c\/td\u003e\n\u003ctd\u003e2 \/ 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShelf loading each \/ total (kg)\u003c\/td\u003e\n\u003ctd\u003e10 \/ 20\u003c\/td\u003e\n\u003ctd\u003e10 \/ 30\u003c\/td\u003e\n\u003ctd\u003e10 \/ 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir changes \/ hr\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax power (W)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding power (W)\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003ctd\u003e465\u003c\/td\u003e\n\u003ctd\u003e622\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note\u003c\/strong\u003e\u003cbr\u003e\u003csmall\u003e- Uniformity is measured in an empty chamber with vents closed, after a stabilisation period\u003cbr\u003e- Shelf loadings are based on evenly distributed weight\u003cbr\u003e- Maximum power and heat up times based on a 240V supply\u003cbr\u003e- The uniform volume is smaller than the total chamber volume\u003cbr\u003e- Minimum operating temperature is ambient +30°C\u003c\/small\u003e\u003c\/p\u003e\n\u003cp class=\"render-target-web\"\u003e\u003csmall\u003eContent may be subject to modifications or corrections\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/brochure_catalogue_general_en.pdf?3364042827712029181\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-5_medium.png?3364042827712029181\"\u003e\u003c\/a\u003e  \u003c\/p\u003e","published_at":"2016-05-16T13:52:00+12:00","created_at":"2016-05-16T13:54:22+12:00","vendor":"Carbolite Gero","type":"Ovens \/ Furnaces","tags":["brand_Carbolite Gero","Capacity_30L","Category_Ovens \/ Furnaces","Features_Fan Assisted","Industry_Industrial Manufacturing","Manufacturer_Carbolite Gero","Temperature_250°C","Type_General"],"price":0,"price_min":0,"price_max":0,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":17774346309,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"AX030-230SN","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"CARBOLITE GERO AX030-230SN Fan Assisted Bench Top Oven 30L","public_title":null,"options":["Default Title"],"price":0,"weight":0,"compare_at_price":null,"inventory_quantity":1,"inventory_management":null,"inventory_policy":"deny","barcode":"","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/acornsci.co.nz\/cdn\/shop\/products\/laboratory_ove.jpg?v=1463363786"],"featured_image":"\/\/acornsci.co.nz\/cdn\/shop\/products\/laboratory_ove.jpg?v=1463363786","options":["Title"],"media":[{"alt":null,"id":53830189155,"position":1,"preview_image":{"aspect_ratio":1.493,"height":469,"width":700,"src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/laboratory_ove.jpg?v=1463363786"},"aspect_ratio":1.493,"height":469,"media_type":"image","src":"\/\/acornsci.co.nz\/cdn\/shop\/products\/laboratory_ove.jpg?v=1463363786","width":700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003cp\u003e\u003cb\u003eThe Apex AX Series Ovens are a range of 250°C laboratory ovens\u003c\/b\u003e, comprising three bench-top sized models that are equipped with the R38 digital PID temperature controller.\u003c\/p\u003e\n\u003ch2\u003eStandard features\u003c\/h2\u003e\n\u003cul id=\"advantages\"\u003e\n\u003cli\u003e250°C maximum operating temperature\u003c\/li\u003e\n\u003cli\u003e30, 60 or 120 litres chamber volumes\u003c\/li\u003e\n\u003cli\u003eEquipped with the \u003ca title=\"Opens internal link in current window\" class=\"internal-link\" href=\"http:\/\/www.carbolite-gero.com\/products\/ovens\/laboratory-ovens\/ax-laboratory-bench-top-oven\/products\/control-options\/r38-basic-controller\/\"\u003eR38 digital PID temperature controller\u003c\/a\u003e\n\u003c\/li\u003e\n\u003cli\u003eFan convection for rapid heating \u0026amp; excellent uniformity\u003c\/li\u003e\n\u003cli\u003eChemically resistant stainless steel liner\u003c\/li\u003e\n\u003cli\u003eTwo adjustable nickel-chrome plated wire shelves\u003c\/li\u003e\n\u003cli\u003eLever latch door \u0026amp; airtight silicone seal\u003c\/li\u003e\n\u003cli\u003eCompliant with safety standard BS EN 61010-2-010:2003\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptions\u003c\/h2\u003e\n\u003cul class=\"list bidspecs\" id=\"options\"\u003e\n\u003cli\u003eOver-temperature protection (recommended to protect valuable contents \u0026amp; for unattended operation)\u003c\/li\u003e\n\u003cli\u003eDigital countdown timer to switch oven off\u003c\/li\u003e\n\u003cli\u003eAdditional sets of shelves \u0026amp; runners\u003c\/li\u003e\n\u003cli\u003eLockable door\u003c\/li\u003e\n\u003cli\u003eLow voltage options for use below 220 V\u003c\/li\u003e\n\u003cli\u003eRoutine spares kit\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"text-image\"\u003e\n\u003cdiv class=\"grid-100 tablet-grid-100\"\u003e\n\u003ch2 class=\"text-center s-small w-medium t-upper\"\u003eLABORATORY OVEN - AX \u003cspan class=\"s-medium w-bold t-upper\"\u003eTECHNICAL DATA\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product_details product-content-features-models\"\u003e\n\u003cdiv class=\"table-wrapper\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003c\/th\u003e\n\u003cth\u003eAX30\u003c\/th\u003e\n\u003cth\u003eAX60\u003c\/th\u003e\n\u003cth\u003eAX120\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax temp\u003c\/td\u003e\n\u003ctd\u003e250°C\u003c\/td\u003e\n\u003ctd\u003e250°C\u003c\/td\u003e\n\u003ctd\u003e250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin temp\u003c\/td\u003e\n\u003ctd\u003eAmbient +30°C\u003c\/td\u003e\n\u003ctd\u003eAmbient +30°C\u003c\/td\u003e\n\u003ctd\u003eAmbient +30°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVolume (litres)\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp uniformity (°C)\u003c\/td\u003e\n\u003ctd\u003e±5.0 @ 250°C\u003c\/td\u003e\n\u003ctd\u003e±5.0 @ 250°C\u003c\/td\u003e\n\u003ctd\u003e±5.0 @ 250°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat-up time (mins)\u003c\/td\u003e\n\u003ctd\u003e23\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecovery time (mins)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions:\u003cbr\u003eInternal H x W x D (mm)\u003c\/td\u003e\n\u003ctd\u003e295 x 300 x 320\u003c\/td\u003e\n\u003ctd\u003e395 x 400 x 420\u003c\/td\u003e\n\u003ctd\u003e495 x 500 x 520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions:\u003cbr\u003eExternal H x W x D (mm)\u003c\/td\u003e\n\u003ctd\u003e440 x 590 x 465\u003c\/td\u003e\n\u003ctd\u003e540 x 690 x 565\u003c\/td\u003e\n\u003ctd\u003e640 x 790 x 665\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShelves fitted \/ accepted\u003c\/td\u003e\n\u003ctd\u003e2 \/ 4\u003c\/td\u003e\n\u003ctd\u003e2 \/ 6\u003c\/td\u003e\n\u003ctd\u003e2 \/ 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShelf loading each \/ total (kg)\u003c\/td\u003e\n\u003ctd\u003e10 \/ 20\u003c\/td\u003e\n\u003ctd\u003e10 \/ 30\u003c\/td\u003e\n\u003ctd\u003e10 \/ 40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir changes \/ hr\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax power (W)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003ctd\u003e2000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHolding power (W)\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003ctd\u003e465\u003c\/td\u003e\n\u003ctd\u003e622\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003ePlease note\u003c\/strong\u003e\u003cbr\u003e\u003csmall\u003e- Uniformity is measured in an empty chamber with vents closed, after a stabilisation period\u003cbr\u003e- Shelf loadings are based on evenly distributed weight\u003cbr\u003e- Maximum power and heat up times based on a 240V supply\u003cbr\u003e- The uniform volume is smaller than the total chamber volume\u003cbr\u003e- Minimum operating temperature is ambient +30°C\u003c\/small\u003e\u003c\/p\u003e\n\u003cp class=\"render-target-web\"\u003e\u003csmall\u003eContent may be subject to modifications or corrections\u003c\/small\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/brochure_catalogue_general_en.pdf?3364042827712029181\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/0931\/0956\/files\/button-5_medium.png?3364042827712029181\"\u003e\u003c\/a\u003e  \u003c\/p\u003e"}

CARBOLITE GERO AX030-230SN Fan Assisted Bench Top Oven 30L

Product Description

The Apex AX Series Ovens are a range of 250°C laboratory ovens, comprising three bench-top sized models that are equipped with the R38 digital PID temperature controller.

Standard features

  • 250°C maximum operating temperature
  • 30, 60 or 120 litres chamber volumes
  • Equipped with the R38 digital PID temperature controller
  • Fan convection for rapid heating & excellent uniformity
  • Chemically resistant stainless steel liner
  • Two adjustable nickel-chrome plated wire shelves
  • Lever latch door & airtight silicone seal
  • Compliant with safety standard BS EN 61010-2-010:2003

Options

  • Over-temperature protection (recommended to protect valuable contents & for unattended operation)
  • Digital countdown timer to switch oven off
  • Additional sets of shelves & runners
  • Lockable door
  • Low voltage options for use below 220 V
  • Routine spares kit

LABORATORY OVEN - AX TECHNICAL DATA

AX30 AX60 AX120
Max temp 250°C 250°C 250°C
Min temp Ambient +30°C Ambient +30°C Ambient +30°C
Volume (litres) 28 66 128
Temp uniformity (°C) ±5.0 @ 250°C ±5.0 @ 250°C ±5.0 @ 250°C
Heat-up time (mins) 23 25 26
Recovery time (mins) 3 3 3
Dimensions:
Internal H x W x D (mm)
295 x 300 x 320 395 x 400 x 420 495 x 500 x 520
Dimensions:
External H x W x D (mm)
440 x 590 x 465 540 x 690 x 565 640 x 790 x 665
Shelves fitted / accepted 2 / 4 2 / 6 2 / 8
Shelf loading each / total (kg) 10 / 20 10 / 30 10 / 40
Air changes / hr 65 28 14
Max power (W) 1000 1500 2000
Holding power (W) 342 465 622
Weight (kg) 24 37 55

Please note
- Uniformity is measured in an empty chamber with vents closed, after a stabilisation period
- Shelf loadings are based on evenly distributed weight
- Maximum power and heat up times based on a 240V supply
- The uniform volume is smaller than the total chamber volume
- Minimum operating temperature is ambient +30°C